7 research outputs found

    Genetic characterization of Toxoplasma gondii from Brazilian wildlife revealed abundant new genotypes

    Get PDF
    This study aimed to isolate and genotype T. gondii from Brazilian wildlife. For this purpose, 226 samples were submitted to mice bioassay and screened by PCR based on 18S rRNA sequences. A total of 15 T. gondii isolates were obtained, including samples from four armadillos (three Dasypus novemcinctus, one Euphractus sexcinctus), three collared anteaters (Tamandua tetradactyla), three whited-lipped peccaries (Tayassu pecari), one spotted paca (Cuniculus paca), one oncilla (Leopardus tigrinus), one hoary fox (Pseudalopex vetulus), one lineated woodpecker (Dryocopus lineatus) and one maned wolf (Chrysocyon brachyurus). DNA from the isolates, originated from mice bioassay, and from the tissues of the wild animal, designated as “primary samples”, were genotyped by PCR–restriction fragment length polymorphism (PCR/RFLP), using 12 genetic markers (SAG1, SAG2, alt.SAG2, SAG3, BTUB, GRA6, c22-8, c29-2, L258, PK1, CS3 and Apico). A total of 17 genotypes were identified, with 13 identified for the first time and four already reported in published literature. Results herein obtained corroborate previous studies in Brazil, confirming high diversity and revealing unique genotypes in this region. Given most of genotypes here identified are different from previous studies in domestic animals, future studies on T. gondii from wildlife is of interest to understand population genetics and structure of this parasite

    Intraocular pressure and its correlation with blood gas parameters in crested caracaras (Caracara plancus) anesthetized with isoflurane and sevoflurane Pressão intra-ocular e sua correlação com parâmetros hemogasométricos em caracarás (Caracara plancus) anestesiados com isofluorano e sevofluorano

    No full text
    The intraocular pressure (IOP) and its correlations with arterial carbon dioxide partial pressure (PaCO2) and arterial pH were studied in five crested caracaras (Caracara plancus) anesthetized with isoflurane (ISO) and sevoflurane (SEV). Baseline IOP values were measured in both eyes (M0). Brachial artery was previously catheterized to obtain blood gas and cardiorespiratory analysis. Anesthesia was induced with 5% ISO and maintained with 2.5% for 40 minutes. IOP measurements and blood samples were evaluated in different moments until the end of the procedure. After recovering, a second anesthesia was induced with 6% SEV and maintained with 3.5%. Parameters were evaluated at the same time points of the previous procedure. IOP reduced significantly (P= 0.012) from M0 at all time points and no significative changes were observed between ISO and SEV anesthesias. Correlation between IOP and PaCO2 and between PIO and blood pH were found only for SEV. IOP and blood pH decreased in parallel with IOP, whereas values of PaCO2 increased in caracaras anesthetized with isoflurane and sevoflurane.<br>Avaliou-se a pressão intra-ocular (PIO) e estimaram-se as correlações entre PIO e pressão de dióxido de carbono (PaCO2) e pH arterial de cinco caracarás (Caracara plancus), anestesiados com isofluorano (ISO) ou sevofluorano (SEV). Valores basais da PIO foram aferidos em ambos os olhos (M0). Cateterizou-se previamente a artéria braquial para obtenção de parâmetros hemogasométricos e cardiorrespiratórios. Anestesia foi induzida com ISO a 5V% e mantida por 40 minutos com 2,5V%. PIO e amostras de sangue foram avaliadas em diferentes momentos até o final do procedimento. Após recuperação, uma segunda anestesia foi realizada com SEV a 6% e mantida com 3,5%. Os parâmetros foram aferidos nos mesmos momentos estabelecidos previamente. A PIO decresceu significativamente (P=0,012) de M0 em todos os momentos e não houve diferença estatística entre ISO e SEV. Correlações significativas entre PIO e PaCO2 e entre PIO e pH sangüíneo foram observadas apenas para a anestesia com SEV. O pH sangüíneo decresceu paralelamente a PIO, enquanto a PaCO2 aumentou, em carcarás anestesiados com isofluorano e sevofluorano
    corecore