44 research outputs found

    Diagnostics for a 1.2 kA, 1 MeV, electron induction injector

    Full text link
    We are constructing a 1.2-kA, 1-MeV, electron induction injector as part of the RTA program, a collaborative effort between LLNL and LBNL to develop relativistic klystrons for Two-Beam Accelerator applications. The RTA injector will also be used in the development of a high-gradient, low-emittance, electron source and beam diagnostics for the second axis of the Dual Axis Radiographic Hydrodynamic Test (DARHT) Facility. The electron source will be a 3.5``-diameter, thermionic, flat-surface, m-type cathode with a maximum shroud field stress of approximately 165 kV/cm. Additional design parameters for the injector include a pulse length of over 150-ns flat top (1% energy variation), and a normalized edge emittance of less than 200 {pi}-mm-mr. Precise measurement of the beam parameters is required so that performance of the RTA injector can be confidently scaled to the 4-kA, 3-MeV, and 2-microsecond pulse parameters of the DARHT injector. Planned diagnostics include an isolated cathode with resistive divider for direct measurement of current emission, resistive wall and magnetic probe current monitors for measuring beam current and centroid position, capacitive probes for measuring A-K gap voltage, an energy spectrometer, and a pepper-pot emittance diagnostic. Details of the injector, beam line, and diagnostics are presented

    Fast Correction Optics to Reduce Chromatic Aberrations in Longitudinally Compressed Ion Beams

    No full text
    Longitudinally compressed ion beam pulses are currently employed in ion-beam based warm dense matter studies [1]. Compression arises from an imposed time-dependent longitudinal velocity ramp followed by drift in a neutralized channel. Chromatic aberrations in the final focusing system arising from this chirp increase the attainable beam spot and reduce the effective fluence on target. We report recent work on fast correction optics that remove the time-dependent beam envelope divergence and minimizes the beam spot on target. We present models of the optical element design and predicted ion beam fluence

    Commissioning Results of the Upgraded Neutralized Drift Compression Experiment

    No full text
    Recent changes to the NDCX beamline offer the promise of higher charge compressed bunches (>15nC), with correspondingly large intensities (>500kW/cm2), delivered to the target plane for ion-beam driven warm dense matter experiments. We report on commissioning results of the upgraded NDCX beamline that includes a new induction bunching module with approximately twice the volt-seconds and greater tuning flexibility, combined with a longer neutralized drift compression channel

    OPTIMIZATION STUDIES FOR THE ADVANCED PHOTOINJECTOR EXPERIMENT (APEX)

    No full text
    The Advanced Photoinjector Experiment (APEX) seeks to validate the design of a proposed high-brightness, normal conducting RF photoinjector gun and bunching cavity feeding a superconducting RF linac to produce nC-scale electron bunches with sub-micron normalized emittances at MHz-scale repetition rates. The beamline design seeks to optimize the slice averaged 6D brightness of the beam prior to injection into a high gradient linac for further manipulation and delivery to an FEL undulator. Details of the proposed beamline layout and electron beam dynamics studies are presented