3,510 research outputs found
High-spectral resolution observations of the 3.29 micron emission feature: Comparison to QCC and PAHs
Two of the most promising explanations for the origin of the interstellar emission features observed at 3.29, 3.4, 6.2, 7.7, 8.6, and 11.3 microns are: quenched carbonaceous composite (QCC) and polycyclic aromatic hydrocarbons (PAHs). High resolution spectra are given of the 3.29 micron emission feature which were taken with the Cooled Grating Array Spectrometer at the NASA Infrared Telescope Facility and previously published. These spectra show that the peak wavelength of the 3.29 micron feature is located at 3.295 + or - 0.005 micron and that it is coincident with the peak absorbance of QCC. The peak wavelength of the 3.29 micron feature appears to be the same in all of the sources observed thus far. However, the width of the feature in HD 44179 and Elias 1 is only 0.023 micron, which is smaller than the 0.043 micron width in NGC 7027, IRAS 21282+5050, the Orion nebula, and BD+30 deg 3639. Spectra of NGC 7027, QCC, and PAHs is shown. QCC matches the 3.29 micron interstellar emission feature very closely in the wavelength of the peak, and it produces a single feature. On the other hand, PAHs rarely match the peak of the interstellar emission feature, and characteristically produce multiple features
More interstellar emission features at 3.3-3.6 micrometers!
The present data set consists of 3.20 to 3.55 micron spectra of HD44179, NGC 7027, BD+30 3639, and Elias 1 obtained with a cooled-grating array spectrometer (CGAS) at the NASA Infrared Telescope Facility. Emission features and details of the emission feature profiles are presented for high resolution spectra. Greater complexity is shown than might be expected. It is significant that the 3.29 micron feature has an invariant central wavelength, even at high resolution, and this strongly supports the case for a very specific substance or mixture of substances which is giving rise to this feature
The development of air shower in the iron absorber
The iron open-sandwich experiments to observe one dimensional development of individual air showers were carried out at Akeno Observatory. One dimensional energy flow, incident energy and production height of shower is estimated using the data of size and age obtained from the above experiment and simple calculation
Crystallization process and some properties of novel transparent machinable calcium-mica glass-ceramics
ArticleCERAMICS INTERNATIONAL. 34(1): 75-79 (2008)journal articl
Comparison of absolute intensity between EAS with gamma-families and general EAS at Mount Norikura
Gamma-families with total energy greater than 10 TeV, found in the EX chamber which was cooperated with the EAS array were combined with EAS triggered by big bursts. The absolute intensity of the size spectrum of these combined EAS was compared with that of general EAS obtained by AS trigger. The EAS with sizes greater than 2x1 million were always accompanied by gamma-families with sigma E sub gamma H 10 TeV, n sub gamma, H 2 and Emin=3 TeV, although the rate of EAS accompaning such gamma-families decreases rapidly as their sizes decrease
Critical Scale-invariance in Healthy Human Heart Rate
We demonstrate the robust scale-invariance in the probability density
function (PDF) of detrended healthy human heart rate increments, which is
preserved not only in a quiescent condition, but also in a dynamic state where
the mean level of heart rate is dramatically changing. This scale-independent
and fractal structure is markedly different from the scale-dependent PDF
evolution observed in a turbulent-like, cascade heart rate model. These results
strongly support the view that healthy human heart rate is controlled to
converge continually to a critical state.Comment: 9 pages, 3 figures. Phys. Rev. Lett., to appear (2004
- …