133 research outputs found

    Dental treatment and risk of variant CJD - a case control study

    Get PDF
    Abstract Objective: Knowledge of risk factors for variant CJD (vCJD) remains limited, but transmission of prion proteins via re-useable medical devices, including dental instruments, or enhanced susceptibility following trauma to the oral cavity is a concern. This study aimed to identify whether previous dental treatment is a risk factor for development of vCJD. Design: Case control study Methods: Risk factor questionnaires completed by interview with relatives of 130 vCJD patients and with relatives of 66 community and 53 hospital controls were examined by a dental surgeon. Responses regarding dental treatments were analysed. Results: We did not find a statistically significant excess of risk of vCJD associated with dental treatments with the exception of extractions in an unmatched analysis of vCJD cases with community controls (p=0.02). However, this result may be explained by multiple testing. Conclusions: This is the first published study to date to examine potential links between vCJD and dental treatment. There was no convincing evidence found of an increased risk of variant CJD associated with reported dental treatment. However, the power of the study is restricted by the number of vCJD cases to date and does not preclude the possibility that some cases have resulted from secondary transmission via dental procedures. Due to the limitations of the data available, more detailed analyses of dental records are required to fully exclude the possibility of transmission via dental treatment

    Storytelling as 'unorthodox' agency:negotiating the 2012 family immigration rules (United Kingdom)

    Get PDF
    This article attends to the lived experience of binational families subject to the 2012 family immigration rules (FIR). It seeks to enrich the pre-existing discussions of family migration within the European Union (EU) and the United Kingdom, focusing on the ‘micro-political’ experiences of those whose lives have been adversely affected by their introduction. It draws on the life writings of binational families, suggesting that a micro-political focus reveals an ongoing neuropolitical experience that traditional accounts of moral agency are ill-equipped to negotiate. The article suggests an unorthodox interpretation of agency premised on storytelling, while probing the tensions that emerge when this lived experience is framed in such a manner. It concludes by positing a series of questions relating to the value of a neuropolitical labelling of the subject and suggests a need to further engage with traumatic interpretations of harm at the intersection of citizenship rights and mobility rights

    The Seagrave family c. 1160-1295, with an edition of the calendar of the Seagrave cartulary

    No full text
    In 2 vols.SIGLEAvailable from British Library Document Supply Centre-DSC:DXN013766 / BLDSC - British Library Document Supply CentreGBUnited Kingdo

    A study of visual and blood contamination on reprocessed endodontic files from general dental practice

    No full text

    Resin-modified glass ionomer, modified composite or conventional glass ionomer for band cementation? an in vitro evaluation

    No full text
    The aims of this study were to compare the mean shear-peel bond strength and predominant site of bond failure of micro-etched orthodontic bands cemented with resin-modified glass ionomer cement (RMGIC; Fuji Ortho LC or 3M Multi-Cure), a modified composite or a conventional GIC. The survival time of bands was also assessed following simulated mechanical stress in a ball mill. One hundred and twenty molar bands were cemented to extracted human third molars. Eighty bands (20 cemented with each cement) were used to assess the debonding force and 40 bands (10 cemented with each cement) were used to determine survival time. The specimens were prepared in accordance with the manufacturers' instructions for each cement. After storage in a humidor at 37 degrees C for 24 hours, the shear debonding force was assessed for each specimen using a Nene M3000 testing machine with a crosshead speed of 1 mm/minute. The predominant site of band failure was recorded visually for all specimens as either at the band/cement or cement/enamel interface. Survival time was assessed following application of mechanical stress in a ball mill. There was no significant difference in mean shear-peel bond strength between the cement groups (P = 0.816). The proportion of specimens failing at each interface differed significantly between cement groups (P < 0.001). The predominant site of bond failure for bands cemented with the RMGIC (Fuji Ortho LC) or the modified composite was at the enamel/cement interface, whereas bands cemented with 3M Multi-Cure failed predominantly at the cement/band interface. Conventional GIC specimens failed mostly at the enamel/cement interface. The mean survival time of bands cemented with either of the RMGICs or with the modified composite was significantly longer than for those cemented with the conventional GIC. The findings indicate that although there appears to be equivalence in the mean shear-peel bond strength of the band cements assessed, the fatigue properties of the conventional GIC when subjected to simulated mechanical stress seem inferior to those of the other cements for band cementation

    Bonded molar tubes - An in vitro evaluation

    No full text
    This study aimed to evaluate the mean shear bond strength of molar tubes with micro-etched bases bonded with either a compomer (Ultra Band-Lok), a resin-modified glass ionomer cement (3M Multi-Cure or Fuji Ortho LC), or a light-cured resin adhesive (Transbond). The amount of adhesive remaining on the tooth surface following tube removal was assessed also. Finally, survival time of molar tubes bonded with each bonding agent was assessed following simulated mechanical fatigue in a ball mill. A total of 120 extracted human third molars were collected and randomly divided into 4 test groups. Thirty teeth (20 to assess debonding force and 10 to assess survival time) were bonded with each adhesive according to the manufacturers' instructions. Debonding was carried out using a Nene M3000 testing machine with a crosshead speed of 0.5 mm/min. The mean shear bond strength of tubes bonded with Transbond was significantly less than that of those bonded with 3M Multi-Cure (P = .0036) or Fuji Ortho LC (P < .0001). Tubes bonded with Ultra Band-Lok also had significantly lower mean shear bond strength than those bonded with Fuji Ortho LC (P = .020). Distribution of adhesive remnant index scores only differed significantly between tubes bonded with 3M Multi-Cure or Transbond. Only 1 molar tube, bonded with Transbond, debonded in the ball mill at 5 hours, but at 50 hours there was no significant difference in the survival time of tubes bonded with any of the bonding agents. Compomer or resin-modified glass ionomer cements appear to be viable alternatives to light-cured resin adhesive for bonding molar tubes
    • …
    corecore