733 research outputs found

    Nanofriction mechanisms derived from the dependence of friction on load and sliding velocity from air to UHV on hydrophilic silicon

    Full text link
    This paper examines friction as a function of the sliding velocity and applied normal load from air to UHV in a scanning force microscope (SFM) experiment in which a sharp silicon tip slides against a flat Si(100) sample. Under ambient conditions, both surfaces are covered by a native oxide, which is hydrophilic. During pump-down in the vacuum chamber housing the SFM, the behavior of friction as a function of the applied normal load and the sliding velocity undergoes a change. By analyzing these changes it is possible to identify three distinct friction regimes with corresponding contact properties: (a) friction dominated by the additional normal forces induced by capillarity due to the presence of thick water films, (b) higher drag force from ordering effects present in thin water layers and (c) low friction due to direct solid-solid contact for the sample with the counterbody. Depending on environmental conditions and the applied normal load, all three mechanisms may be present at one time. Their individual contributions can be identified by investigating the dependence of friction on the applied normal load as well as on the sliding velocity in different pressure regimes, thus providing information about nanoscale friction mechanisms

    Analytical and biological variability in biomarker measurement in the Hispanic Community Health Study/Study of Latinos

    Get PDF
    Biomarker variability, which includes within-individual variability (CVI), between-individual variability (CVG) and methodological variability (CVP+A) is an important determinant of our ability to detect biomarker-disease associations. Estimates of CVI and CVG may be population specific and little data exists on biomarker variability in diverse Hispanic populations. Hence, we evaluated all 3 components of biomarker variability in the Hispanic Community Health Study/Study of Latinos (HCHS/SOL) using repeat blood collections (n=58) and duplicate blood measurements (n = 761 – 929 depending on the biomarker)

    Lectures on the functional renormalization group method

    Full text link
    These introductory notes are about functional renormalization group equations and some of their applications. It is emphasised that the applicability of this method extends well beyond critical systems, it actually provides us a general purpose algorithm to solve strongly coupled quantum field theories. The renormalization group equation of F. Wegner and A. Houghton is shown to resum the loop-expansion. Another version, due to J. Polchinski, is obtained by the method of collective coordinates and can be used for the resummation of the perturbation series. The genuinely non-perturbative evolution equation is obtained in a manner reminiscent of the Schwinger-Dyson equations. Two variants of this scheme are presented where the scale which determines the order of the successive elimination of the modes is extracted from external and internal spaces. The renormalization of composite operators is discussed briefly as an alternative way to arrive at the renormalization group equation. The scaling laws and fixed points are considered from local and global points of view. Instability induced renormalization and new scaling laws are shown to occur in the symmetry broken phase of the scalar theory. The flattening of the effective potential of a compact variable is demonstrated in case of the sine-Gordon model. Finally, a manifestly gauge invariant evolution equation is given for QED.Comment: 47 pages, 11 figures, final versio

    Accuracy and repeatability of wrist joint angles in boxing using an electromagnetic tracking system

    Get PDF
    © 2019, The Author(s). The hand-wrist region is reported as the most common injury site in boxing. Boxers are at risk due to the amount of wrist motions when impacting training equipment or their opponents, yet we know relatively little about these motions. This paper describes a new method for quantifying wrist motion in boxing using an electromagnetic tracking system. Surrogate testing procedure utilising a polyamide hand and forearm shape, and in vivo testing procedure utilising 29 elite boxers, were used to assess the accuracy and repeatability of the system. 2D kinematic analysis was used to calculate wrist angles using photogrammetry, whilst the data from the electromagnetic tracking system was processed with visual 3D software. The electromagnetic tracking system agreed with the video-based system (paired t tests) in both the surrogate ( 0.9). In the punch testing, for both repeated jab and hook shots, the electromagnetic tracking system showed good reliability (ICCs > 0.8) and substantial reliability (ICCs > 0.6) for flexion–extension and radial-ulnar deviation angles, respectively. The results indicate that wrist kinematics during punching activities can be measured using an electromagnetic tracking system

    A Systematic Survey of Mini-Proteins in Bacteria and Archaea

    Get PDF
    BACKGROUND: Mini-proteins, defined as polypeptides containing no more than 100 amino acids, are ubiquitous in prokaryotes and eukaryotes. They play significant roles in various biological processes, and their regulatory functions gradually attract the attentions of scientists. However, the functions of the majority of mini-proteins are still largely unknown due to the constraints of experimental methods and bioinformatic analysis. METHODOLOGY/PRINCIPAL FINDINGS: In this article, we extracted a total of 180,879 mini-proteins from the annotations of 532 sequenced genomes, including 491 strains of Bacteria and 41 strains of Archaea. The average proportion of mini-proteins among all genomic proteins is approximately 10.99%, but different strains exhibit remarkable fluctuations. These mini-proteins display two notable characteristics. First, the majority are species-specific proteins with an average proportion of 58.79% among six representative phyla. Second, an even larger proportion (70.03% among all strains) is hypothetical proteins. However, a fraction of highly conserved hypothetical proteins potentially play crucial roles in organisms. Among mini-proteins with known functions, it seems that regulatory and metabolic proteins are more abundant than essential structural proteins. Furthermore, domains in mini-proteins seem to have greater distributions in Bacteria than Eukarya. Analysis of the evolutionary progression of these domains reveals that they have diverged to new patterns from a single ancestor. CONCLUSIONS/SIGNIFICANCE: Mini-proteins are ubiquitous in bacterial and archaeal species and play significant roles in various functions. The number of mini-proteins in each genome displays remarkable fluctuation, likely resulting from the differential selective pressures that reflect the respective life-styles of the organisms. The answers to many questions surrounding mini-proteins remain elusive and need to be resolved experimentally

    Comparison of the efficacy of a neutral wrist splint and wrist splint with lumbrical unit for the treatment of patients with carpal tunnel syndrome

    Get PDF
    Purpose: The purpose of this study was to compare the effect of a neutral wrist splint or a wrist splint with an additional metacarpophalangeal (MCP) unit on pain, function, grip and pinch strength in patients with mild-to-moderate carpal tunnel syndrome (CTS). Methods: Twenty four patients received conservative treatment using either the neutral wrist splint or wrist splint with the MCP unit for a period of 6 weeks. Primary outcome measures were pain, function, grip and pinch strength. Data was collected immediately before and after using the two types of splints at baseline (0 weeks) and 6 weeks. Statistical analysis was performed using the paired t-test and independent T-test. Results: Compared to baseline, both the neutral wrist splint and the wrist splint with an MCP unit significantly decreased pain, increased function and pinch and grip strength. Comparisons of the two types of splints for grip (P =0.675) and pinch strength (P =0.650) revealed that there were no significant differences between the two after 6 weeks of wear. However, there were significant differences in pain levels (P =0.022) and the DASH score (P =0.027) between the two types of splints from baseline to 6 weeks. Conclusion: The wrist splint with an MCP unit was more effective than the neutral wrist splint in pain reduction and improvement of function

    Demographics of extra-articular calcaneal fractures: Including a review of the literature on treatment and outcome

    Get PDF
    Introduction: Extra-articular calcaneal fractures represent 25-40% of all calcaneal fractures and an even higher percentage of up to 60% is seen in children. A disproportionately small part of the literature on calcaneal fractures involves the extra-articular type. The aim of this study was to investigate the incidence of extra-articular calcaneal fractures in a Level 1 trauma centre, define the distribution of the various types of fractures and compare patient demographics between extra- and intra-articular calcaneal fractures. In addition the literature was reviewed for the most common types of extra-articular calcaneal fractures with regard to incidence, treatment and clinical outcome. Methods: The radiological records between 2003 and 2005 were reviewed for intra- and extra-articular calcaneal fractures. Patient gender-distribution and age were compared. A literature search was conducted for the treatment of extra-articular calcaneal fractures. Results: In this 3-year study period a total of 49 patients with 50 extra-articular calcaneal fractures and 91 patients with 101 intra-articular fractures were identified. The median age for the first group was 32.7 years, and for the second group 40.3 years; P = 0.04. Male predominance was significantly less pronounced for extra-articular (63%) compared with intra-articular fractures (79%; P = 0.04). Conclusion: One-third of all calcaneal fractures are extra-articular. Significant differences exist between the intra- and extra-articular groups, in terms of lower age and male-female ratio. The literature study shows inconsistencies in treatment options, but most extra-articular fractures are well manageable conservatively

    Lived religion: Rethinking human nature in a neoliberal age

    Get PDF
    This article considers the relationship between philosophy of religion and an approach to the study of religion, which prioritises the experience of lived religion. Considering how individuals and communities live out their faith challenges some of the assumptions of analytic philosophers of religion regarding the position the philosopher should adopt when approaching the investigation of religion. If philosophy is understood principally as a means for analysing belief, it will have little space for an engagement with what it feels like to live out one’s faith
    • …
    corecore