108 research outputs found

    Echocardiographic Parameters for Risk Prediction in Borderline Right Ventricle: Review with Special Emphasis on Pulmonary Atresia with Intact Ventricular Septum and Critical Pulmonary Stenosis

    Get PDF
    The aim of the present review is to highlight the strengths and limitations of echocardiographic parameters and scores employed to predict favorable outcome in complex congenital heart diseases (CHDs) with borderline right ventricle (RV), with a focus on pulmonary atresia with intact ventricular septum and critical pulmonary stenosis (PAIVS/CPS). A systematic search in the National Library of Medicine using Medical Subject Headings and free-text terms including echocardiography, CHD, and scores, was performed. The search was refined by adding keywords “PAIVS/CPS”, Ebstein’s anomaly, and unbalanced atrioventricular septal defect with left dominance. A total of 22 studies were selected for final analysis; 12 of them were focused on parameters to predict biventricular repair (BVR)/pulmonary blood flow augmentation in PAIVS/CPS. All of these studies presented numerical (the limited sample size) and methodological limitations (retrospective design, poor definition of inclusion/exclusion criteria, variability in the definition of outcomes, differences in adopted surgical and interventional strategies). There was heterogeneity in the echocardiographic parameters employed and cut-off values proposed, with difficultly in establishing which one should be recommended. Easy scores such as TV/MV (tricuspid/mitral valve) and RV/LV (right/left ventricle) ratios were proven to have a good prognostic accuracy; however, the data were very limited (only two studies with <40 subjects). In larger studies, RV end-diastolic area and a higher degree of tricuspid regurgitation were also proven as accurate predictors of successful BVR. These measures, however, may be either operator and/or load/pressure dependent. TV Z-scores have been proposed by several authors, but old and heterogenous nomograms sources have been employed, thus producing discordant results. In summary, we provide a review of the currently available echocardiographic parameters for risk prediction in CHDs with a diminutive RV that may serve as a guide for use in clinical practice

    Intracardiac left atrial tuberculoma in an eleven-month-old infant: case report

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Cardiac tuberculosis is rare and usually manifests as tuberculous pericarditis. Involvement of other part of the heart is unusual and descriptions in the pediatric literature are confined to few case reports regarding mainly myocardial tuberculosis.</p> <p>Case presentation</p> <p>We describe a case of pulmonary miliary tuberculosis associated with intracardiac left atrial tuberculoma in an immunocompetent eleven-month-old infant successfully treated with surgery and antituberculous therapy.</p> <p>Conclusion</p> <p>Although unusual, involvement of endocardium in disseminated tuberculosis should be kept in mind.</p

    Clinical value of patient-specific three-dimensional printing of congenital heart disease: Quantitative and qualitative assessments

    Get PDF
    Objective: Current diagnostic assessment tools remain suboptimal in demonstrating complex morphology of congenital heart disease (CHD). This limitation has posed several challenges in preoperative planning, communication in medical practice, and medical education. This study aims to investigate the dimensional accuracy and the clinical value of 3D printed model of CHD in the above three areas. Methods: Using cardiac computed tomography angiography (CCTA) data, a patient-specific 3D model of a 20-month-old boy with double outlet right ventricle was printed in Tango Plus material. Pearson correlation coefficient was used to evaluate correlation of the quantitative measurements taken at analogous anatomical locations between the CCTA images pre- and post-3D printing. Qualitative analysis was conducted by distributing surveys to six health professionals (two radiologists, two cardiologists and two cardiac surgeons) and three medical academics to assess the clinical value of the 3D printed model in these three areas. Results: Excellent correlation (r = 0.99) was noted in the measurements between CCTA and 3D printed model, with a mean difference of 0.23 mm. Four out of six health professionals found the model to be useful in facilitating preoperative planning, while all of them thought that the model would be invaluable in enhancing patient-doctor communication. All three medical academics found the model to be helpful in teaching, and thought that the students will be able to learn the pathology quicker with better understanding. Conclusion: The complex cardiac anatomy can be accurately replicated in flexible material using 3D printing technology. 3D printed heart models could serve as an excellent tool in facilitating preoperative planning, communication in medical practice, and medical education, although further studies with inclusion of more clinical cases are needed

    State of the art of immunoassay methods for B-type natriuretic peptides: An update

    Get PDF
    The aim of this review article is to give an update on the state of the art of the immunoassay methods for the measurement of B-type natriuretic peptide (BNP) and its related peptides. Using chromatographic procedures, several studies reported an increasing number of circulating peptides related to BNP in human plasma of patients with heart failure. These peptides may have reduced or even no biological activity. Furthermore, other studies have suggested that, using immunoassays that are considered specific for BNP, the precursor of the peptide hormone, proBNP, constitutes a major portion of the peptide measured in plasma of patients with heart failure. Because BNP immunoassay methods show large (up to 50%) systematic differences in values, the use of identical decision values for all immunoassay methods, as suggested by the most recent international guidelines, seems unreasonable. Since proBNP significantly cross-reacts with all commercial immunoassay methods considered specific for BNP, manufacturers should test and clearly declare the degree of cross-reactivity of glycosylated and non-glycosylated proBNP in their BNP immunoassay methods. Clinicians should take into account that there are large systematic differences between methods when they compare results from different laboratories that use different BNP immunoassays. On the other hand, clinical laboratories should take part in external quality assessment (EQA) programs to evaluate the bias of their method in comparison to other BNP methods. Finally, the authors believe that the development of more specific methods for the active peptide, BNP1–32, should reduce the systematic differences between methods and result in better harmonization of results

    Reference intervals for the echocardiographic measurements of the right heart in children and adolescents: a systematic review

    Get PDF
    BACKGROUND: Transthoracic echocardiography is the primary imaging modality for the diagnosis of right ventricular (RV) involvement in congenital and acquired heart diseases. There is increasing recognition of the contribution of RV dysfunction in heart diseases affecting children and adolescents, but there is insufficient information on reference intervals for the echocardiographic measurements of the right heart in children and adolescents that represent all the continental populations of the world.OBJECTIVE:The aim of this systematic review was to collate, from published studies, normative data for echocardiographic evaluation of the right heart in children and adolescents, and to identify gaps in knowledge in this field especially with respect to sub-Saharan Africans. METHODS: We performed a systematic literature search to identify studies of reference intervals for right heart measurements as determined by transthoracic echocardiography in healthy children and adolescents of school-going age. Articles were retrieved from electronic databases with a combination of search terms from the earliest date available until May 2013. RESULTS: Reference data were available for a broad range of variables. Fifty one studies out of 3096 publications were included. The sample sizes of the reference populations ranged from 13 to 2036 with ages varying from 5 to 21 years. We identified areas lacking sufficient reference data. These included reference data for determining right atrial size, tricuspid valve area, RV dimensions and areas, the RV % fractional area change, pulmonary artery pressure gradients and the right-sided haemodynamics, including the inferior vena cava dimensions and collapsibility. There were no data for sub-Saharan African children and adolescents. CONCLUSION: Reliable reference data are lacking for important echocardiographic measurements of the RV in children and adolescents, especially for sub-Saharan Africans
    corecore