272 research outputs found

    Imaging Immune Surveillance of Individual Natural Killer Cells Confined in Microwell Arrays

    Get PDF
    New markers are constantly emerging that identify smaller and smaller subpopulations of immune cells. However, there is a growing awareness that even within very small populations, there is a marked functional heterogeneity and that measurements at the population level only gives an average estimate of the behaviour of that pool of cells. New techniques to analyze single immune cells over time are needed to overcome this limitation. For that purpose, we have designed and evaluated microwell array systems made from two materials, polydimethylsiloxane (PDMS) and silicon, for high-resolution imaging of individual natural killer (NK) cell responses. Both materials were suitable for short-term studies (<4 hours) but only silicon wells allowed long-term studies (several days). Time-lapse imaging of NK cell cytotoxicity in these microwell arrays revealed that roughly 30% of the target cells died much more rapidly than the rest upon NK cell encounter. This unexpected heterogeneity may reflect either separate mechanisms of killing or different killing efficiency by individual NK cells. Furthermore, we show that high-resolution imaging of inhibitory synapse formation, defined by clustering of MHC class I at the interface between NK and target cells, is possible in these microwells. We conclude that live cell imaging of NK-target cell interactions in multi-well microstructures are possible. The technique enables novel types of assays and allow data collection at a level of resolution not previously obtained. Furthermore, due to the large number of wells that can be simultaneously imaged, new statistical information is obtained that will lead to a better understanding of the function and regulation of the immune system at the single cell level

    Introducing a New Algorithm for Classification of Etiology in Studies on Pediatric Pneumonia: Protocol for the Trial of Respiratory Infections in Children for Enhanced Diagnostics Study

    Get PDF
    Background: There is a need to better distinguish viral infections from antibiotic-requiring bacterial infections in children presenting with clinical community-acquired pneumonia (CAP) to assist health care workers in decision making and to improve the rational use of antibiotics.Objective: The overall aim of the Trial of Respiratory infections in children for ENhanced Diagnostics (TREND) study is to improve the differential diagnosis of bacterial and viral etiologies in children aged below 5 years with clinical CAP, by evaluating myxovims resistance protein A (MxA) as a biomarker for viral CAP and by evaluating an existing (multianalyte point-of-care antigen detection test system [mariPOC respi] ArcDia International Oy Ltd.) and a potential future point-of-care test for respiratory pathogens.Methods: Children aged 1 to 59 months with clinical CAP as well as healthy, hospital-based, asymptomatic controls will be included at a pediatric emergency hospital in Stockholm, Sweden. Blood (analyzed for MxA and C-reactive protein) and nasopharyngeal samples (analyzed with real-time polymerase chain reaction as the gold standard and antigen-based mariPOC respi test as well as saved for future analyses of a novel recombinase polymerase amplification-based point-of-care test for respiratory pathogens) will be collected. A newly developed algorithm for the classification of CAP etiology will be used as the reference standard.Results: A pilot study was performed from June to August 2017. The enrollment of study subjects started in November 2017. Results are expected by the end of 2019.Conclusions: The findings from the TREND study can be an important step to improve the management of children with clinical CAP

    High-Density Microwell Chip for Culture and Analysis of Stem Cells

    Get PDF
    With recent findings on the role of reprogramming factors on stem cells, in vitro screening assays for studying (de)-differentiation is of great interest. We developed a miniaturized stem cell screening chip that is easily accessible and provides means of rapidly studying thousands of individual stem/progenitor cell samples, using low reagent volumes. For example, screening of 700,000 substances would take less than two days, using this platform combined with a conventional bio-imaging system. The microwell chip has standard slide format and consists of 672 wells in total. Each well holds 500 nl, a volume small enough to drastically decrease reagent costs but large enough to allow utilization of standard laboratory equipment. Results presented here include weeklong culturing and differentiation assays of mouse embryonic stem cells, mouse adult neural stem cells, and human embryonic stem cells. The possibility to either maintain the cells as stem/progenitor cells or to study cell differentiation of stem/progenitor cells over time is demonstrated. Clonality is critical for stem cell research, and was accomplished in the microwell chips by isolation and clonal analysis of single mouse embryonic stem cells using flow cytometric cell-sorting. Protocols for practical handling of the microwell chips are presented, describing a rapid and user-friendly method for the simultaneous study of thousands of stem cell cultures in small microwells. This microwell chip has high potential for a wide range of applications, for example directed differentiation assays and screening of reprogramming factors, opening up considerable opportunities in the stem cell field
    corecore