42 research outputs found

    Conductance-strain behavior in silver-nanowire composites: network properties of a tunable strain sensor

    Get PDF
    Highly flexible and conductive nano-composite materials are promising candidates for stretchable and flexible electronics. We report on the strain–resistance relation of a silver-nanowire photopolymer composite during repetitive stretching. Resistance measurements reveal a gradual change of the hysteretic resistance curves towards a linear and non-hysteretic behavior. Furthermore, a decrease in resistance and an increase in electrical sensitivity to strain over the first five stretching cycles can be observed. Sensitivity gauge factors between 10 and 500 at 23% strain were found depending on the nanowire concentration and stretching cycle. We model the electrical behavior of the investigated silver nanowire composites upon repetitive stretching considering the strain induced changes in the local force distribution within the polymer matrix and the tunnel resistance between the nanowires by using a Monte Carlo method

    Catalytic Oxygenation of Hydrocarbons by Mono-mu-oxo Dicopper(II) Species Resulting from O-O Cleavage of Tetranuclear Cu-I/Cu-II Peroxo Complexes

    No full text
    One of the challenges of catalysis is the transformation of inert C−H bonds to useful products. Copper-containing monooxygenases play an important role in this regard. Here we show that low-temperature oxygenation of dinuclear copper(I) complexes leads to unusual tetranuclear, mixed-valent μ4μ_4-peroxo [CuI^I/CuII^{II}]2_2 complexes. These Cu4_4O2_2 intermediates promote irreversible and thermally activated O−O bond homolysis, generating Cu2_2O complexes that catalyze strongly exergonic H-atom abstraction from hydrocarbons, coupled to O-transfer. The Cu2_2O species can also be produced with N2_2O, demonstrating their capability for small-molecule activation. The binding and cleavage of O2_2 leading to the primary Cu4_4O2_2 intermediate and the Cu2_2O complexes, respectively, is elucidated with a range of solution spectroscopic methods and mass spectrometry. The unique reactivities of these species establish an unprecedented, 100 % atom-economic scenario for the catalytic, copper-mediated monooxygenation of organic substrates, employing both O-atoms of O2_2

    Jet delivery system for Raman scattering on bio-inorganic compounds

    No full text
    We present a micro-jet sample delivery system for Raman measurements. Compared to cuvette measurements, the observed Raman signal is enhanced by more than one order of magnitude and does not contain signal distortions from the liquid-glass interface. Furthermore, the signal stability of repeated measurements is enhanced due to reduced sample damage effects by constantly replenishing the sample. This allows the study of sensitive samples that can only be produced in low concentrations. Our setup consists of a controlled sample environment that can be either under vacuum or an exchange gas, which allows the study of samples that are unstable in air. Finally, by matching the effective source point of the Raman instrument with the diameter of the jet, controlled experiments using laser beams of different wavelengths are possible. We see future applications of our setup for resonance Raman and time-resolved Raman measurements of bioinorganic samples

    The TRIXS end station for femtosecond timeresolved resonant inelastic x ray scattering experiments at the soft x ray free electron laser FLASH

    No full text
    We present the experimental end station TRIXS dedicated to time resolved soft x ray resonant inelastic x ray scattering RIXS experiments on solid samples at the free electron laser FLASH. Using monochromatized ultrashort femtosecond XUV soft x ray photon pulses in combination with a synchronized optical laser in a pump probe scheme, the TRIXS setup allows measuring sub picosecond time resolved highresolution RIXS spectra in the energy range from 35 eV to 210 eV, thus spanning the M edge M1 and M2,3 absorption resonances of 3d transition metals and N4,5 edges of rare earth elements. A Kirkpatrick Baez refocusing mirror system at the first branch of the plane grating monochromator beamline PG1 provides a focus of 6 6 lm2 FWHM at the sample. The RIXS spectrometer reaches an energy resolution of 35 160 meV over the entire spectral range. The optical laser system based on a chirped pulse optical parametric amplifier provides approximately 100 fs FWHM long photon pulses at the fundamental wavelength of 800 nm and a fluence of 120 mJ cm2 at a sample for optical pump XUV probe measurements. Furthermore, optical frequency conversion enables experiments at 400 nm or 267 nm with a fluence of 80 and 30 mJ cm2, respectively. Some of the first pump probe RIXS spectra measured with this setup are shown. The measured time resolution for time resolved RIXS measurements has been characterized as 287 fs FWHM for the used energy resolutio

    Functional Printing of Conductive Silver-Nanowire Photopolymer Composites

    No full text
    We investigated the fabrication and functional behaviour of conductive silver-nanowire-polymer composites for prospective use in printing applications. Silver-nanowires with an aspect ratio of up to 1000 were synthesized using the polyol route and embedded in a UV-curable and printable polymer matrix. Sheet resistances in the composites down to 13 Ω/sq at an optical transmission of about 90% were accomplished. The silver-nanowire composite morphology and network structure was investigated by electron microscopy, atomic force microscopy, profilometry, ellipsometry as well as surface sensitive X-ray scattering. By implementing different printing applications, we demonstrate that our silver nanowires can be used in different polymer composites. On the one hand, we used a tough composite for a 2D-printed film as top contact on a solar cell. On the other hand, a flexible composite was applied for a 3D-printed flexible capacitor

    The TRIXS end-station for femtosecond time-resolved resonant inelastic X-ray free-electron laser FLASH

    No full text
    We present the experimental end-station TRIXS dedicated to time-resolved soft x-ray resonant inelastic x-ray scattering (RIXS) experiments on solid samples at the free-electron laser FLASH. Using monochromatized ultrashort femtosecond XUV/soft x-ray photon pulses in combination with a synchronized optical laser in a pump-probe scheme, the TRIXS setup allows measuring sub-picosecond time-resolved high-resolution RIXS spectra in the energy range from 35 eV to 210 eV, thus spanning the M-edge (M1_1 and M2,3_{2,3}) absorption resonances of 3d transition metals and N4,5_{4,5}-edges of rare earth elements. A Kirkpatrick–Baez refocusing mirror system at the first branch of the plane grating monochromator beamline (PG1) provides a focus of (6 × 6) μm2μm^2 (FWHM) at the sample. The RIXS spectrometer reaches an energy resolution of 35–160 meV over the entire spectral range. The optical laser system based on a chirped pulse optical parametric amplifier provides approximately 100 fs (FWHM) long photon pulses at the fundamental wavelength of 800 nm and a fluence of 120 mJ/cm2^2 at a sample for optical pump-XUV probe measurements. Furthermore, optical frequency conversion enables experiments at 400 nm or 267 nm with a fluence of 80 and 30 mJ/cm2^2, respectively. Some of the first (pump-probe) RIXS spectra measured with this setup are shown. The measured time resolution for time-resolved RIXS measurements has been characterized as 287 fs (FWHM) for the used energy resolution
    corecore