141 research outputs found

    Mindfulness Meditation and Brain Signals: A Review

    Get PDF
    Medical science is already started to spread various effects of meditation on the brain using different tools and techniques like FMRI, brain mapping technology, EEG. This allows the researchers to be able to determine the outcome of meditation on the brain and brain rhythms. In clinical problems also the meditation plays the main role in solving the many mental and physical problems like chronic pain. In this paper, we see different types of meditation like yoga, TM, sahaji yoga, raj yoga, zen meditation their effects on the physical and psychological health of human being. Also, study the basics of EEG signals and the brain rhythms and behavioral states. Acknowledge the effect of meditation on brain through EEG signals

    Formulation, development and evaluation of Microsponge loaded Topical Gel of Nystatin

    Get PDF
    Nystatin containing microsponge as active constituent (API) in different formulations by changing the proportions of drug (Nystatin), polymer (ethyl cellulose), emulsifier (Poly vinyl alcohol) were obtained successfully using quasi-emulsion solvent diffusion method. These formulations were studied for particle size and physical characterization. Scanning electron microscopy (SEM) images showed the microsponges porous and spherical in shape. The physical characterization showed that microsponge formulation coded by P6 showed a better loading efficiency and production yield. This microsponge formulation was prepared as gel in carbopol and studied for pH, viscosity, spreadability, drug content, in-vitro release. The microsponge formulation gel, F3 showed viscosity3465.84cps,spreadability of 26.22g cm/s and drug content of 89.65%. The nystatin microsponge gel formulations showed an appropriate drug release profile. F3 released 81.03% of drug at 12 hours. Keywords: Microsponge, Solvent diffusion method, Scanning electron microscope, Nystatin microsponge gel

    Renal Transplantation in Hepatitis C Positive Patients: A Single Centre Experience

    Get PDF
    Introduction. Hepatitis C virus (HCV) infection is an independent risk factor for renal transplantation (RTx). Immunosuppression minimization can render better quality of life to these patients. Methods. We analyzed 132 HCV-positive RTx patients (group A) transplanted under tolerance induction protocol (TIP) and compared them with 79 controls (group B) transplanted using standard triple drugs. TIP consisted of 1 donor-specific transfusion, peripheral blood stem cell infusion, portal infusion of bone marrow, and target-specific irradiation. Their immunosuppression was cyclosporin, 2 Β± 1 mg/kg BW/day + prednisone, 10 mg/day. Results. TIP had no side effects. Although unequal in size, the groups were well balanced. Group A patient survival at 1, 5, and 10 years was 92.4%, 70.4%, and 63.7%, respectively, versus 75.6%, 71.7%, and 55.7% in later, and graft survival was 92.9%, 81.5%, and 79.1% versus 91.7%, 75.7%, and 67.7%, respectively. Mean serum creatinine (mg/dL) at these time periods in former was 1.38, 1.72, and 1.87, versus 1.3, 1.75, and 2.1 in later. Altered liver functions were noted in 22% patients in former versus 31% in later. Group A had lesser rejection episodes. Conclusion. RTx using TIP in HCV-positive patients is a viable option with acceptable outcome

    Computational model of blood flow in the aorto-coronary bypass graft

    Get PDF
    BACKGROUND: Coronary artery bypass grafting surgery is an effective treatment modality for patients with severe coronary artery disease. The conduits used during the surgery include both the arterial and venous conduits. Long- term graft patency rate for the internal mammary arterial graft is superior, but the same is not true for the saphenous vein grafts. At 10 years, more than 50% of the vein grafts would have occluded and many of them are diseased. Why do the saphenous vein grafts fail the test of time? Many causes have been proposed for saphenous graft failure. Some are non-modifiable and the rest are modifiable. Non-modifiable causes include different histological structure of the vein compared to artery, size disparity between coronary artery and saphenous vein. However, researches are more interested in the modifiable causes, such as graft flow dynamics and wall shear stress distribution at the anastomotic sites. Formation of intimal hyperplasia at the anastomotic junction has been implicated as the root cause of long- term graft failure. Many researchers have analyzed the complex flow patterns in the distal sapheno-coronary anastomotic region, using various simulated model in an attempt to explain the site of preferential intimal hyperplasia based on the flow disturbances and differential wall stress distribution. In this paper, the geometrical bypass models (aorto-left coronary bypass graft model and aorto-right coronary bypass graft model) are based on real-life situations. In our models, the dimensions of the aorta, saphenous vein and the coronary artery simulate the actual dimensions at surgery. Both the proximal and distal anastomoses are considered at the same time, and we also take into the consideration the cross-sectional shape change of the venous conduit from circular to elliptical. Contrary to previous works, we have carried out computational fluid dynamics (CFD) study in the entire aorta-graft-perfused artery domain. The results reported here focus on (i) the complex flow patterns both at the proximal and distal anastomotic sites, and (ii) the wall shear stress distribution, which is an important factor that contributes to graft patency. METHODS: The three-dimensional coronary bypass models of the aorto-right coronary bypass and the aorto-left coronary bypass systems are constructed using computational fluid-dynamics software (Fluent 6.0.1). To have a better understanding of the flow dynamics at specific time instants of the cardiac cycle, quasi-steady flow simulations are performed, using a finite-volume approach. The data input to the models are the physiological measurements of flow-rates at (i) the aortic entrance, (ii) the ascending aorta, (iii) the left coronary artery, and (iv) the right coronary artery. RESULTS: The flow field and the wall shear stress are calculated throughout the cycle, but reported in this paper at two different instants of the cardiac cycle, one at the onset of ejection and the other during mid-diastole for both the right and left aorto-coronary bypass graft models. Plots of velocity-vector and the wall shear stress distributions are displayed in the aorto-graft-coronary arterial flow-field domain. We have shown (i) how the blocked coronary artery is being perfused in systole and diastole, (ii) the flow patterns at the two anastomotic junctions, proximal and distal anastomotic sites, and (iii) the shear stress distributions and their associations with arterial disease. CONCLUSION: The computed results have revealed that (i) maximum perfusion of the occluded artery occurs during mid-diastole, and (ii) the maximum wall shear-stress variation is observed around the distal anastomotic region. These results can enable the clinicians to have a better understanding of vein graft disease, and hopefully we can offer a solution to alleviate or delay the occurrence of vein graft disease

    Prognostic role of p27Kip1 and apoptosis in human breast cancer

    Get PDF
    Human breast carcinoma is biologically heterogeneous, and its clinical course may vary from an indolent slowly progressive one to a course associated with rapid progression and metastatic spread. It is important to establish prognostic factors which will define subgroups of patients with low vs high risk of recurrence so as to better define the need for additional therapy. Additional characterization of the molecular make-up of breast cancer phenotypes should provide important insights into the biology of breast cancer. In the present study, we investigated apoptosis, expression of p27Kip1 and p53 retrospectively in 181 human breast cancer specimens. In addition, their relevance to the biological behaviour of breast cancer was examined. Our studies found a significant association among high histological grade, high p53, low apoptosis and low p27. Our results also demonstrated that, in human breast cancer, low levels of p27 and apoptotic index (AI) strongly correlated with the presence of lymph node metastasis and decreased patient survival. In node-negative patients, however, p27 also had prognostic value for relapse-free and overall survival in multivariate analysis. Furthermore p27 and AI had predictive value for the benefits of chemotherapy. These latter observations should prompt prospective randomized studies designed to investigate the predictive role of p27 and AI in determining who should receive chemotherapy in node-negative patients. Β© 1999 Cancer Research Campaig

    Alterations in regional vascular geometry produced by theoretical stent implantation influence distributions of wall shear stress: analysis of a curved coronary artery using 3D computational fluid dynamics modeling

    Get PDF
    BACKGROUND: The success of stent implantation in the restoration of blood flow through areas of vascular narrowing is limited by restenosis. Several recent studies have suggested that the local geometric environment created by a deployed stent may influence regional blood flow characteristics and alter distributions of wall shear stress (WSS) after implantation, thereby rendering specific areas of the vessel wall more susceptible to neointimal hyperplasia and restenosis. Stents are most frequently implanted in curved vessels such as the coronary arteries, but most computational studies examining blood flow patterns through stented vessels conducted to date use linear, cylindrical geometric models. It appears highly probable that restenosis occurring after stent implantation in curved arteries also occurs as a consequence of changes in fluid dynamics that are established immediately after stent implantation. METHODS: In the current investigation, we tested the hypothesis that acute changes in stent-induced regional geometry influence distributions of WSS using 3D coronary artery CFD models implanted with stents that either conformed to or caused straightening of the primary curvature of the left anterior descending coronary artery. WSS obtained at several intervals during the cardiac cycle, time averaged WSS, and WSS gradients were calculated using conventional techniques. RESULTS: Implantation of a stent that causes straightening, rather than conforms to the natural curvature of the artery causes a reduction in the radius of curvature and subsequent increase in the Dean number within the stented region. This straightening leads to modest skewing of the velocity profile at the inlet and outlet of the stented region where alterations in indices of WSS are most pronounced. For example, time-averaged WSS in the proximal portion of the stent ranged from 8.91 to 11.7 dynes/cm(2 )along the pericardial luminal surface and 4.26 to 4.88 dynes/cm(2 )along the myocardial luminal surface of curved coronary arteries as compared to 8.31 dynes/cm(2 )observed throughout the stented region of a straight vessel implanted with an equivalent stent. CONCLUSION: The current results predicting large spatial and temporal variations in WSS at specific locations in curved arterial 3D CFD simulations are consistent with clinically observed sites of restenosis. If the findings of this idealized study translate to the clinical situation, the regional geometry established immediately after stent implantation may predispose portions of the stented vessel to a higher risk of neointimal hyperplasia and subsequent restenosis

    Axial stent strut angle influences wall shear stress after stent implantation: analysis using 3D computational fluid dynamics models of stent foreshortening

    Get PDF
    INTRODUCTION: The success of vascular stents in the restoration of blood flow is limited by restenosis. Recent data generated from computational fluid dynamics (CFD) models suggest that the vascular geometry created by an implanted stent causes local alterations in wall shear stress (WSS) that are associated with neointimal hyperplasia (NH). Foreshortening is a potential limitation of stent design that may affect stent performance and the rate of restenosis. The angle created between axially aligned stent struts and the principal direction of blood flow varies with the degree to which the stent foreshortens after implantation. METHODS: In the current investigation, we tested the hypothesis that stent foreshortening adversely influences the distribution of WSS and WSS gradients using time-dependent 3D CFD simulations of normal arteries based on canine coronary artery measurements of diameter and blood flow. WSS and WSS gradients were calculated using conventional techniques in ideal (16 mm) and progressively foreshortened (14 and 12 mm) stented computational vessels. RESULTS: Stent foreshortening increased the intrastrut area of the luminal surface exposed to low WSS and elevated spatial WSS gradients. Progressive degrees of stent foreshortening were also associated with strut misalignment relative to the direction of blood flow as indicated by analysis of near-wall velocity vectors. CONCLUSION: The current results suggest that foreshortening may predispose the stented vessel to a higher risk of neointimal hyperplasia
    • …
    corecore