24 research outputs found
Lifetimes of excited states in P-, As- and Sb-
Radiative lifetimes of three elements of the nitrogen group have been
experimentally investigated at the Double ElectroStatic Ion Ring Experiment
(DESIREE) facility at Stockholm University. The experiments were performed
through selective laser photodetachment of excited states of P, As and
Sb ions stored in a cryogenic storage ring. The experimental results were
compared with theoretically predicted lifetimes, yielding a mixture of very
good agreements in some cases and large discrepancies in others. These results
are part of our efforts to map out the lifetimes of all excited states in
negative ions. This data can be used to benchmark atomic theories, in
particularly with respect to the degree of electron correlation that is
incorporated in various theoretical models
Galantamine improves olfactory learning in the Ts65Dn mouse model of Down syndrome
Down syndrome (DS) is the most common form of congenital intellectual disability. Although DS involves multiple disturbances in various tissues, there is little doubt that in terms of quality of life cognitive impairment is the most serious facet and there is no effective treatment for this aspect of the syndrome. The Ts65Dn mouse model of DS recapitulates multiple aspects of DS including cognitive impairment. Here the Ts65Dn mouse model of DS was evaluated in an associative learning paradigm based on olfactory cues. In contrast to disomic controls, trisomic mice exhibited significant deficits in olfactory learning. Treatment of trisomic mice with the acetylcholinesterase inhibitor galantamine resulted in a significant improvement in olfactory learning. Collectively, our study indicates that olfactory learning can be a sensitive tool for evaluating deficits in associative learning in mouse models of DS and that galantamine has therapeutic potential for improving cognitive abilities
A Monte Carlo study of the energy dependence of Al<sub>2</sub>O<sub>3</sub>: C crystals for real-time in vivo dosimetry in mammography
In a previous experimental study, a novel method for in vivo dosimetry has been investigated, based on radioluminescence (RL) and optically stimulated luminescence (OSL). However, because of (fie large difference in atomic composition between the detector material and the breast tissue, relatively large energy dependence in low-energy X-ray beams can be expected. In the present work, the energy dependence of Al2O3:C crystals was modelled with the Monte Carlo code EGSnre using three types of X-ray spectra. The results obtained (5.6-7.3%) agree with a previously determined experimental result (9%) within the combined standard uncertainty of the two methods. The influence of the size of the crystal on the energy dependence was investigated together with the effect of varying the thickness of the surrounding light-protective material. The results obtained indicate a minor effect owing to the thickness of the light-protective material, and a somewhat larger effect from reducing the diameter of the crystal. The outcome of this study can be used to improve the future design of the RL/OSI. dosimetry system for use in mammography
Threshold pixel size for shape determination of microcalcifications in digital mammography: a pilot study.
The effect of pixel size on shape determination in screening digital mammography systems was studied using a shape identification task as the measured outcome. Ten microcalcifications on screen-films were digitised to a range of pixel sizes (2.5-200 μm) and extracted from computed radiography (CR) images (50 μm) acquired under equivalent imaging conditions. Fifteen observers attempted to identify the shape of each microcalcification at each pixel size. The results were collated to provide a fraction of correct responses vs. pixel size curve for each microcalcification. Averaging over all shapes, pixel values > 100 μm lead to a significant decrease in shape determination ability (p < 0.01) for digitised screen-film. For CR images, half the shapes were not properly identified. Hence, although 20-100 μm was sufficient for microcalcification shape determination for digitised screen-film images, 50 μm was only borderline sufficient for the CR digital image
A software tool for increased efficiency in observer performance studies in radiology
Observer performance studies are time-consurning tasks, both for the participating observers and for the scientists collecting and analysing the data. A possible way to optimise such studies is to perform them in a completely digital environment. A software tool-ViewDEX (Viewer for Digital Evaluation of X-ray images)-has been developed in Java, enabling it to function on almost any computer. ViewDEX is designed to handle several types of studies, such as visual grading analysis (VGA), image criteria scoring (ICS) and receiver operating characteristics (ROC). The results from each observer are saved in a log file, which can be exported for further analysis in, for example, a special software for analysing ROC results. By using ViewDEX for an ROC experiment, an evaluation rate of similar to 200 images per hour can be achieved, compared to similar to 25 images per hour using hard copy evaluation. The results are obtained within minutes of completion of the viewing. The risk of human errors in the process of data collection and analysis is also minimised. The viewer has been used in a major trial containing similar to 2700 images
In vivo absorbed dose measurements in mammography using a new real-time luminescence technique
A dosimetry system based on radioluminescence (RL) and optically stimulated luminescence (OSL) from carbon doped aluminium oxide (Al2O3:C) crystals was developed for in vivo absorbed dose measurements in mammography. A small cylindrical crystal of Al2O3:C (diameter 0.48 mm and length 2 mm) was coupled to the end of a 1 mm diameter optical fibre cable. Owing to their small size and characteristic shape, these probes can be placed on the body surface in the field of view during the examination, without compromising the reading of the mammogram. Our new technique was tested with a mammography unit (Siemens Mammomat 3000) and screen-film technique over a range of clinically relevant X-ray energies. The results were compared with those obtained from an ionization chamber usually used for the determination of absorbed dose in mammography. The reproducibility of measurements was around 3% (1 standard deviation) at 4.5 mGy for both RL and OSL data. The dose response was found to be linear between 4.5 mGy and 30 mGy. The energy dependence of the system is around 18% between 23 kV and 35 kV. In vivo measurements were performed during three patient examinations. It was shown that entrance and exit doses could be measured. The presence of the small probes did not significantly interfere with the diagnostic quality of the images. Entrance doses estimated by RL/OSL results agreed within 3% with entrance surface dose values calculated from the ionization chamber measurements. These results indicate a considerable potential for use in routine control and in vivo dose measurements in mammography