23 research outputs found

    Endoscopic fluorescence-guided surgery for sinonasal cancer using an antibody-dye conjugate

    Get PDF
    First published:19 December 2019OBJECTIVE: Endoscopic resection of sinonasal squamous cell carcinoma has become the standard of care, but challenges remain in obtaining clear resection margins. The current study evaluated the feasibility of endoscopic fluorescence-guided surgery (FGS) to improve surgical resection in a human sinus surgical model. METHODS: A fluorescence endoscope optimized for near-infrared (NIR) fluorescence detection was evaluated in a phantom study. Various endoscope diameters (4 and 10 mm) and viewing angles (0, 30, and 45 degrees) were evaluated to determine the sensitivity of the system for IRDye800CW detection at various working distances (1-5 cm). Endoscopic FGS was then validated in a three-dimensional human sinus surgical model to which squamous cell tumors derived from mice were inserted. Mice had received intravenous panitumumab-IRDye800CW and upon fluorescence-guided tumor resection, mean fluorescence intensity (MFI) and tumor-to-background ratio (TBR) were calculated in in situ and ex vivo settings. RESULTS: A significantly higher fluorescence intensity was found when using the 10-mm diameter endoscope compared to the 4mm diameter endoscope (P < .001). No significant difference in MFI was found among the viewing angles of the 4-mm diameter endoscope. Using the human sinus model, the highest MFI and TBR were obtained at a 1-cm working distance compared to longer working distances. CONCLUSION: We demonstrate that clinically acceptable TBRs were obtained with several working distances to discriminate tumor tissue from adjacent normal tissue in a human sinus model, and that endoscopic FGS may have great potential in identifying residual tumor tissue regions during surgery. Laryngoscope, 2019.Zachary P. Hart, Naoki Nishio, Giri Krishnan, Guolan Lu, Quan Zho

    Low back pain in older adults: risk factors, management options and future directions

    Full text link

    Proportional upregulation of CD97 isoforms in glioblastoma and glioblastoma-derived brain tumor initiating cells

    No full text
    © 2015 Safaee et al.CD97 is a novel glioma antigen that confers an invasive phenotype and poor survival in patients with glioblastoma (GBM), the most aggressive primary malignant brain tumor. The short isoform of CD97, known as EGF(1,2,5), has been shown

    The sentinel margin: Intraoperative ex vivo specimen mapping using relative fluorescence intensity

    No full text
    Purpose: Despite major advancements in surgical oncology, the positive margin rate for primary head and neck cancer resection remains around 15%-30%. In particular, the deep surface margin is the most challenging to adequately assess. Inadequate margins are directly correlated to poor survival, and as such, mitigation of these rates is critical to improve patient outcomes. We have developed an ex vivo imaging strategy that utilizes fluorescence intensity peaks (relative to background signal) of an injected anti-EGFR antibody conjugated to a fluorescent probe to locate potential close or positive margins on the deep surface of the resected tumor specimen. Experimental Design: Twelve patients with head and neck cancer scheduled for surgery received systemic administration of a tumor-specific contrast-agent (panitumumab- IRDye800CW). After surgical resection, the tumor specimen was imaged using a fluorescence imager. The three highest fluorescence intensity-peaks on the deep surface of the specimen were isolated and correlated to histology to determine the margin distance at these regions. Results: Relative fluorescence peak intensities identified the closest margin on the deep surface of the specimen within 2.5 minutes. The highest intensity peak consistently (100%) detected the closest margin to the tumor. The difference in tumor margin distance between the first and second highest fluorescence intensity peak averaged 2.1 ± 1.4 mm. The tumor-margin difference between the second and third highest peak averaged 1.6 ± 0.6 mm. Conclusions: Fluorescence intensity peaks can identify the region on the specimen where tumor is closest to specimen's edge on the deep surface. This technique could have broad applications in obtaining adequate margins in oncological surgery

    Fluorescence molecular imaging for identification of high-grade dysplasia in patients with head and neck cancer

    Get PDF
    Objective: High-grade dysplasia is associated with a risk of malignant transformation, and it is necessary to distinguish from normal epithelium or low-grade dysplasia, especially in the intraoperative setting. We hypothesize that an anti-epidermal growth factor receptor (EGFR) contrast agent can be used to differentiate high-grade dysplasia from low-grade dysplasia and normal epithelium. Materials and methods: Patients with biopsy proven head and neck squamous cell carcinoma (HNSCC) were enrolled in a clinical trial using systemically injected fluorescently labeled anti-EGFR antibody (panitumumab-IRDye800CW) (NCT02415881). Paraffin embedded tumor specimens from 11 patients were evaluated by fluorescence histopathology. Hematoxylin and eosin (H&E) slides were reviewed by a board-certified pathologist, and regions of invasive squamous cell carcinoma, high-grade dysplasia and low-grade dysplasia were delineated. EGFR expression was assessed for each patient by way of immunohistochemistry. Results: 11 patients were included in the study with a total of 219 areas on tissue sections analyzed; 68 normal epithelium, 53 low-grade dysplasia, 48 high-grade dysplasia, and 50 malignant regions. The signal-to-background ratio (SBR) increased proportionally with increasing grade of dysplasia; normal epithelium (1.5 ± 0.1), low-grade dysplasia (1.8 ± 0.1), high-grade dysplasia: (2.3 ± 0.2). High-grade dysplasia had a significantly higher SBR when compared to normal or low-grade dysplasia (p < 0.05). Fluorescence histopathology positively correlated with EGFR expression by immunohistochemistry, which also increased proportionally with increasing degree of dysplasia. Conclusion: Molecular imaging with an anti-EGFR agent can successfully discriminate high-grade dysplastic lesions from low-grade dysplasia and normal epithelium

    Optimal dosing strategy for fluorescence-guided surgery with Panitumumab-IRDye800CW in head and neck cancer

    No full text
    Purpose: To identify the optimal dosing strategy for fluorescence-guided surgery in patients with head and neck squamous cell carcinoma, we conducted a dose-ranging study evaluating the anti-epidermal growth factor receptor (EGFR) therapeutic antibody, panitumumab, that was fluorescently labeled with the near-infrared dye IRDye800CW. Procedures: Patients (n = 24) received either 0.5 or 1.0 mg/kg panitumumab-IRDye800CW in the weight-based dosing group or 25 or 50 mg panitumumab-IRDye800CW in the fixed dosing group. Following surgery, whole primary specimens were imaged in a closed-field device and the mean fluorescence intensity (MFI) and tumor-to-background ratio (TBR) were assessed. Clinical variables, including dose, time of infusion-to-surgery, age, unlabeled dose, gender, primary tumor site, and tumor size, were analyzed to evaluate the factors affecting the fluorescence intensity in order to identify the optimal dose for intraoperative fluorescence imaging. Results: A total of 24 primary tumor specimens were imaged and analyzed in this study. Although no correlations between TBR and dose of panitumumab-IRDye800CW were found, there were moderate–strong correlations between the primary tumor MFI and panitumumab-IRDye800CW dose for fixed dose (mg) (R2 = 0.42) and for dose/weight (mg/kg) (R2 = 0.54). Results indicated that the optimal MFI was at approximately 50 mg for fixed dose and 0.75 mg/kg for dose/weight. No significant differences were found for the primary tumor MFI and TBRs between the weight-based dosing and the fixed dosing groups. MFIs significantly increased when the infusion-to-surgery window was reduced to within 2 days (vs. 3 days or more, p < 0.05). Conclusions: Antibody-based imaging for surgical resection is under investigation in multiple clinical trials. Our data suggests that a fixed dose of 50 mg is an appropriate diagnostic dose for successful surgical fluorescence imaging

    Intraoperative Tumor Assessment Using Real-Time Molecular Imaging in Head and Neck Cancer Patients

    No full text
    Background: In head and neck cancer, surgical resection using primarily visual and tactile feedback is considered the gold standard for solid tumors. Due to high numbers of tumor-involved surgical margins, which are directly correlated to poor clinical outcomes, intraoperative optical imaging trials have rapidly proliferated over the past 5 years. However, few studies report on intraoperative in situ imaging data that could support surgical resection. To demonstrate the clinical application of in situ surgical imaging, we report on the imaging data that are directly (ie in real-time) available to the surgeon. Study Design: Fluorescence intensities and tumor-to-background ratios (TBRs) were determined from the intraoperative imaging data–the view as seen by the surgeon during tumor resection–of 20 patients, and correlated to patient and tumor characteristics including age, sex, tumor site, tumor size, histologic differentiation, and epidermal growth factor receptor (EGFR) expression. Furthermore, different lighting conditions in regard to surgical workflow were evaluated. Results: Under these circumstances, intraoperative TBRs of the primary tumors averaged 2.2 ± 0.4 (range 1.5 to 2.9). Age, sex, tumor site, and tumor size did not have a significant effect on open-field intraoperative molecular imaging of the primary tumors (p > 0.05). In addition, variation in EGFR expression levels or the presence of ambient light did not seem to alter TBRs. Conclusions: We present the results of successful in situ intraoperative imaging of primary tumors alongside the optimal conditions with respect to both molecular image acquisition and surgical workflow. This study illuminates the potentials of open-field molecular imaging to assist the surgeon in achieving successful cancer removal
    corecore