6 research outputs found

    Inferior outcome after hip resurfacing arthroplasty than after conventional arthroplasty: Evidence from the Nordic Arthroplasty Register Association (NARA) database, 1995 to 2007

    Get PDF
    Today, total hip arthroplasty (THA) is one of the safest and most efficient surgical treatments. New materials, surgical techniques and design concepts intended to improve THA have not always been successful. Thorough preclinical and early clinical investigations can detect some aspects of under-performing, while continuing surveillance is recommended to detect and analyze reasons for any later appearing flaws. In this thesis, several ways to monitor and assess THA performance are explored and carried out, using survival analysis in registry studies, radiostereometry (RSA), radiology and clinical outcome. In Paper I, a study using the Nordic Arthroplasty Register Association (NARA) registry shows that HRA had an almost 3-fold increased early non-septic revision risk and that risk factors were found to be female sex, certain HRA designs and units having performed few HRA procedures. Papers II and III contain comparisons of highly cross-linked polyethylene (XLPE) and conventional polyethylene (PE). XLPE had a considerably lower wear rate up to 10 years but showed no obvious improvements regarding implant fixation, BMD or clinical outcome. In the NARA registry, in 2 of 4 studied cup designs the XLPE version had a lower risk of revision for aseptic loosening compared to the PE version. Paper IV describes that stem subsidence and retrotorsion measured with RSA at 2 years predicted later aseptic stem failure in an unfavorably altered, previously well-functioning cemented femoral stem. In Paper V and VI, a novel approach to measure articulation wear with RSA in radiodense hip arthroplasty articulations was presented and evaluated. Subsequently, a comparison between ceramic-on-ceramic (COC) and metal-on-conventional PE uncemented THA displayed a considerably lower wear rate, smaller periacetabular bone lesions and a relatively high squeaking rate, the latter with unknown long-term consequences, in the COC hips. Implant fixation, heterotopic ossification and clinical outcome did not differ between articulation types. In conclusion, it was confirmed that implant surveillance can be done with RSA, also in radiodense THA. Early migration predicts later aseptic implant failure. Prolonged surveillance can confirm long-term material and design performance, verify or contradict anticipated advantages as well as detect unanticipated long-term complications

    Primary anastomosis and suturing combined with vacuum-assisted abdominal closure in patients with secondary peritonitis due to perforation of the small intestine: a retrospective study

    No full text
    Abstract Background Intestinal resection and a proximal stoma is the preferred surgical approach in patients with severe secondary peritonitis due to perforation of the small intestine. However, proximal stomas may result in significant nutritional problems and long-term parenteral nutrition. This study aimed to assess whether primary anastomosis or suturing of small intestine perforation is feasible and safe using the open abdomen principle with vacuum-assisted abdominal closure (VAC). Methods Between January 2005 and June 2018, we performed a retrospective chart review of 20 patients (> 18 years) with diffuse faecal peritonitis caused by small intestinal perforation and treated with primary anastomosis/suturing and subsequent open abdomen with VAC. Results The median age was 65 years (range: 23–90 years). Twelve patients were female (60%). Simple suturing of the small intestinal perforation was performed in three cases and intestinal resection with primary anastomosis in 17 cases. Four patients (20%) died within 90-days postoperatively. Leakage occurred in five cases (25%), and three patients developed an enteroatmospheric fistula (15%). Thirteen of 16 patients (83%) who survived were discharged without a stoma. The rest had a permanent stoma. Conclusions Primary suturing or resection with anastomosis and open abdomen with VAC in small intestinal perforation with severe faecal peritonitis is associated with a high rate of leakage and enteroatmospheric fistula formation. Trial registration The study was approved by the Danish Patient Safety Authority (case number 3-3013-1555/1) and the Danish Data Protection Agency (file number 18/28,404). No funding was received

    Physician staffed emergency medical service for children: a retrospective population-based registry cohort study in Odense region, Southern Denmark

    No full text
    Objectives The aim of this study is to determine diagnostic patterns in the prehospital paediatric population, age distribution, the level of monitoring and the treatment initiated in the prehospital paediatric case. Hypothesis was that advanced prehospital interventions are rare in the paediatric patient population. Setting We performed a retrospective population-based registry cohort study of children attended by a physician-staffed emergency medical service (EMS) unit (P-EMS), in the Odense area of Denmark during a 10-year study period. Participants We screened 44 882 EMS contacts and included 5043 children. Patient characteristics, monitoring and interventions performed by the P-EMS crews were determined. Results We found that paediatric patients were a minority among patients attended by P-EMS units: 11.2% (10.9 to 11.5) (95% CI) of patients were children. The majority of the children were <5 years old; one-third being <2 years old. Respiratory problems, traffic accidents and febrile seizures were the three most common dispatch codes. Oxygen supplementation, intravenous access and application of a cervical collar were the three most common interventions. Oxygen saturation and heart rate were documented in more than half of the cases, but more than one-third of the children had no vital parameters documented. Only 22% of the children had respiratory rate, saturation, heart rate and blood pressure documented. Prehospital invasive procedures such as tracheal intubation (n=74), intraosseous access (n=22) and chest drainage (n=2) were infrequently performed. Conclusion Prehospital paediatric contacts are uncommon, more frequently involving smaller children. Monitoring or at least documentation of basic vital parameters is infrequent and may be an area for improvement. Advanced and potentially life-saving prehospital interventions provide a dilemma since these likely occur too infrequently to allow service providers to maintain their technical skills working solely in the prehospital environment
    corecore