1,897 research outputs found
Millimeter-Wave Diffraction by a Photo-Induced Plasma Grating
Optical gratings are used extensively for beamsteering in the visible and IR range of the spectrum. Change in the dielectric permittivity of a semiconductor medium resulting from the excitation of a nonequilibrium electron-hole plasma makes it possible to extend this technique to MMW frequencies. A photo-induced plasma grating (PIPG) can be easily rewritten by changing the illumination pattern. So this technique can be used in optically controllable MMW antennas. Initial experimental work studied the diffraction of MMW propagating along a dielectric waveguide containing a PIPG. This paper reports on the diffraction of MMW propagating in free space, steered by the PIPG
A Java Program for LRE-Based Real-Time qPCR that Enables Large-Scale Absolute Quantification
Background: Linear regression of efficiency (LRE) introduced a new paradigm for real-time qPCR that enables large-scale absolute quantification by eliminating the need for standard curves. Developed through the application of sigmoidal mathematics to SYBR Green I-based assays, target quantity is derived directly from fluorescence readings within the central region of an amplification profile. However, a major challenge of implementing LRE quantification is the labor intensive nature of the analysis. Findings: Utilizing the extensive resources that are available for developing Java-based software, the LRE Analyzer was written using the NetBeans IDE, and is built on top of the modular architecture and windowing system provided by the NetBeans Platform. This fully featured desktop application determines the number of target molecules within a sample with little or no intervention by the user, in addition to providing extensive database capabilities. MS Excel is used to import data, allowing LRE quantification to be conducted with any real-time PCR instrument that provides access to the raw fluorescence readings. An extensive help set also provides an in-depth introduction to LRE, in addition to guidelines on how to implement LRE quantification. Conclusions: The LRE Analyzer provides the automated analysis and data storage capabilities required by large-scale qPCR projects wanting to exploit the many advantages of absolute quantification. Foremost is the universal perspective afforded by absolute quantification, which among other attributes, provides the ability to directly compare quantitative data produced by different assays and/or instruments. Furthermore, absolute quantification has important implications for gene expression profiling in that it provides the foundation for comparing transcript quantities produced by any gene with any other gene, within and between samples
Disposal of Household Wastewater in Soils of High Stone Content (1981-1983)
Four experimental filter fields were constructed with built-in monitoring equipment in Nixa soils. These soils contain many chert fragments and a fragipan about 60 cm below the soil surface. The fragipan restricts downward movement of water and is the designlimitingfeature. The four filter fields were: 1. A standard filter field, 76 cm deep. The bottom of the trench was in the fragipan. 2. A modified standard filter field, 30 cm deep. The bottom of the trench was above the fragipan. 3. A modified pressure filter field, 40 cm deep. The bottom of the trench was above the fragipan. In addition, a pressure-distribution system was used to insure uniform distribution of effluent in the trench. Inadvertently, this field was installed in a different soil, and the results cannot be compared directly with the other three. 4. Another modified pressure filter field with the bottom of the trench only 6 cm below the soil surface. Observation of these systems confirms that placing filter fields higher in the soil above the hydraulically limiting horizon results in improved hydraulic performance. The presence of the fragipan amplified the adverse effects attributable to climatic stress. The seepage beds which are higher in the soil profile are able to handle the effluent load and climate load with less danger of surfacing
Evolution of Medical Students\u27 Understanding of Systems-Based Practice: A Qualitative Account
Reflective writing is a useful tool in medical education to analyze student experiences and measure development of certain skills. This tool is particularly useful in identifying skill components of systems-based practice. These skills are necessary for any practicing physician, but are of particular importance as they are a required residency competency. There is now additional focus on systems-based practice with the passage of the Patient Protection and Affordable Care Act (ACA). In this qualitative, grounded theory study, the reflective writings of students at a United States medical school were analyzed using the constant comparative method to explore how the focus of a medical student progresses through the clinical curriculum. The interprofessional team of researchers specifically sought to determine if areas of medical student focus evolve vertically across the curriculum and if in the process students develop an understanding of systems-based practice. The data supported both of these objectives, and actively supports future research to identify ways, both inside and outside the curriculum, to leverage the studentsâ natural progression of focus in order to expand systems-based practice education
The effects of transparency on perceived and actual competence of a content-based recommender.
Perceptions of a systemâs competence influence acceptance
of that system [31]. Ideally, usersâ perception of
competence matches the actual competence of a system.
This paper investigates the relation between actual and
perceived competence of transparent Semantic Web
recommender systems that explain recommendations in
terms of shared item concepts. We report an experiment
comparing non-transparent and transparent versions of a
content-based recommender. Results indicate that in the
transparent condition, perceived competence and actual
competence (in specific recall) were related, while in the
non-transparent condition they were not. Providing insight
in what aspects of items triggered their recommendation, by
showing the concepts that were the basis for a
recommendation, gave users a better assessment of how
well the system worked
Neutron rich matter, neutron stars, and their crusts
Neutron rich matter is at the heart of many fundamental questions in Nuclear
Physics and Astrophysics. What are the high density phases of QCD? Where did
the chemical elements come from? What is the structure of many compact and
energetic objects in the heavens, and what determines their electromagnetic,
neutrino, and gravitational-wave radiations? Moreover, neutron rich matter is
being studied with an extraordinary variety of new tools such as Facility for
Rare Isotope Beams (FRIB) and the Laser Interferometer Gravitational Wave
Observatory (LIGO). We describe the Lead Radius Experiment (PREX) that is using
parity violation to measure the neutron radius in 208Pb. This has important
implications for neutron stars and their crusts. Using large scale molecular
dynamics, we model the formation of solids in both white dwarfs and neutron
stars. We find neutron star crust to be the strongest material known, some 10
billion times stronger than steel. It can support mountains on rotating neutron
stars large enough to generate detectable gravitational waves. Finally, we
describe a new equation of state for supernova and neutron star merger
simulations based on the Virial expansion at low densities, and large scale
relativistic mean field calculations.Comment: 10 pages, 2 figures, Plenary talk International Nuclear Physics
Conference 2010, Vancouver, C
A 23 GHz Survey of GRB Error Boxes
The Haystack 37-meter telescope was used in a pilot project in May 1995 to
observe GRB error boxes at 23~GHz. Seven BATSE error boxes and two IPN arcs
were scanned by driving the beam of the telescope rapidly across their area.
For the BATSE error boxes, the radio observations took place two to eighteen
days after the BATSE detection, and several boxes were observed more than once.
Total power data were recorded continuously as the telescope was driven at a
rate of 0.2~degrees/second, yielding Nyquist sampling of the beam with an
integration time of 50~milliseconds, corresponding to a theoretical rms
sensitivity of 0.5~Jy. Under conditions of good weather, this sensitivity was
achieved. In a preliminary analysis of the data we detect only two sources,
3C273 and 0552+398, both catalogued sources that are known to be variable at
23~GHz. Neither had a flux density that was unusally high or low at the time of
our observations.Comment: 5 pages, 1 postscript figure. To appear in Proceedings of the Third
Huntsville Symposium on Gamma-Ray Bursts (eds. C. Kouveliotou, M. S. Briggs,
and G. J. Fishman
- âŠ