39 research outputs found

    Function of anterior talofibular and calcaneofibular ligaments during in-vivo motion of the ankle joint complex

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Despite the numerous in-vitro studies on the mechanical properties and simulated injury mechanisms of the anterior talofibular ligament (ATFL) and calcaneofibular ligament (CFL), the in-vivo biomechanical behavior of these two ligaments has not yet been described.</p> <p>Methods</p> <p>Apparent length of the ATFL and CFL was measured in four ankles in healthy male subjects between 32 and 45 years of age (two left and two right) during a dorsiflexion-plantarflexion and supination-pronation arc of motion using a combined dual-orthogonal fluoroscopic and magnetic resonance imaging technique.</p> <p>Results</p> <p>The ATFL elongated from the neutral position at 16.3 +/- 3.0 mm to 20.8 +/- 2.7 mm at maximal plantarflexion and shortened significantly from the neutral position to 13.9 +/- 2.9 mm at maximal dorsiflexion (<it>p </it>= 0.01). The CFL shortened from the neutral position at 28.0 +/- 2.9 mm to 26.6 +/- 2.2 mm at maximal plantarflexion (<it>p </it>= 0.08) and elongated significantly from the neutral position to 29.9 +/- 3.0 mm at maximal dorsiflexion (<it>p </it>= 0.003). The ATFL elongated significantly from 14.8 +/- 2.5 mm at maximal pronation to 17.4 +/- 3.0 mm at maximal supination (<it>p </it>= 0.08). At the same time, the CFL shortened from 31.0 +/- 3.8 mm at maximal pronation to 26.9 +/- 3.6 mm at maximal supination (<it>p </it>= 0.02).</p> <p>Conclusion</p> <p>The results showed that the ATFL elongates more during plantarflexion and supination whereas the CFL increases in length with dorsiflexion and pronation. Concurrently, these data also demonstrated the reciprocal function between the two ligaments. While one shortens, the other one elongates. The different elongation of the ATFL and CFL during the same motion arc suggests that under excessive loading conditions the ATFL might be more vulnerable in plantarflexion and supination while the CFL might be more susceptible to injury in dorsiflexion and pronation. Furthermore, in the case of surgical reconstruction the grafts used to reconstruct the two ligaments may need to be tensioned at different positions of the ankle in order to reproduce their natural in vivo function.</p

    Morphology of the medial collateral ligament of the knee

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Quantitative knowledge on the anatomy of the medial collateral ligament (MCL) is important for treatment of MCL injury and for MCL release during total knee arthroplasty (TKA). The objective of this study was to quantitatively determine the morphology of the MCL of human knees.</p> <p>Methods</p> <p>10 cadaveric human knees were dissected to investigate the MCL anatomy. The specimens were fixed in full extension and this position was maintained during the dissection and morphometric measurements. The outlines of the insertion sites of the superficial MCL (sMCL) and deep MCL (dMCL) were digitized using a 3D digitizing system.</p> <p>Results</p> <p>The insertion areas of the superficial MCL (sMCL) were 348.6 ± 42.8 mm<sup>2 </sup>and 79.7 ± 17.6 mm<sup>2 </sup>on the tibia and femur, respectively. The insertion areas of the deep MCL (dMCL) were 63.6 ± 13.4 mm<sup>2 </sup>and 71.9 ± 14.8 mm<sup>2 </sup>on the tibia and femur, respectively. The distances from the centroids of the tibial and femoral insertions of the sMCL to the tibial and femoral joint line were 62.4 ± 5.5 mm and 31.1 ± 4.6 mm, respectively. The distances from the centroids of dMCL in the tibial insertion and the femoral insertion to the tibial and femoral joint line were 6.5 ± 1.3 mm and 20.5 ± 4.2 mm, respectively. The distal portion of the dMCL (meniscotibial ligament - MTL) was approximately 1.7 times wider than the proximal portion of the dMCL (meniscofemoral ligament - MFL), whereas the MFL was approximately 3 times longer than the MTL.</p> <p>Conclusions</p> <p>The morphologic data on the MCL may provide useful information for improving treatments of MCL-related pathology and performing MCL release during TKA.</p

    Risk of Complication and Revision Total Hip Arthroplasty Among Medicare Patients with Different Bearing Surfaces

    Get PDF
    To address the long-term problems of bearing surface wear and osteolysis associated with conventional metal-polyethylene (M-PE) total hip arthroplasty (THA), metal-metal (M-M), and ceramic-ceramic (C-C) bearings have been introduced. These bearing surfaces are associated with unique risks and benefits and higher costs. However the relative risks of these three bearings in an older population is unknown. We compared the short-term risk of complication and revision THA among Medicare patients having a primary THA with metal-polyethylene (M-PE), metal-metal (M-M), and ceramic-ceramic (C-C) bearings. We used the 2005 to 2007 100% Medicare inpatient claim files to perform a matched cohort analysis in three separate cohorts of THA patients (M-PE, M-M, and C-C) who were matched by age, gender, and US census region. Multivariate Cox proportional-hazards models were constructed to compare complication and revision THA risk among cohorts, adjusting for medical comorbidities, race, socioeconomic status, and hospital factors. After adjusting for patient and hospital factors, M-M bearings were associated with a higher risk of periprosthetic joint infection (hazard ratio, 3.03; confidence interval, 1.02–9.09) when compared with C-C bearings (0.59% versus 0.32%, respectively). There were no other differences among bearing cohorts in the adjusted risk of revision THA or any other complication. The risk of short-term complication (including dislocation) and revision THA were similar among appropriately matched Medicare THA patients regardless of bearing surface. Hard-on-hard THA bearings are of questionable value in Medicare patients, given the higher cost associated with their use and uncertain long-term benefits in older patients. Level II, prognostic study. See Guidelines for Authors for a complete description of levels of evidence

    The Epidemiology of Revision Total Knee Arthroplasty in the United States

    Get PDF
    Understanding the cause of failure and type of revision total knee arthroplasty (TKA) procedures performed in the United States is essential in guiding research, implant design, and clinical decision making in TKA. We assessed the causes of failure and specific types of revision TKA procedures performed in the United States using newly implemented ICD-9-CM diagnosis and procedure codes related to revision TKA data from the Nationwide Inpatient Sample (NIS) database. Clinical, demographic, and economic data were reviewed and analyzed from 60,355 revision TKA procedures performed in the United States between October 1, 2005 and December 31, 2006. The most common causes of revision TKA were infection (25.2%) and implant loosening (16.1%), and the most common type of revision TKA procedure reported was all component revision (35.2%). Revision TKA procedures were most commonly performed in large, urban, nonteaching hospitals in Medicare patients ages 65 to 74. The average length of hospital stay (LOS) for all revision TKA procedures was 5.1 days, and the average total charges were $49,360. However, average LOS, average charges, and procedure frequencies varied considerably by census region, hospital type, and procedure performed

    New fluoroscopic imaging technique for investigation of 6DOF knee kinematics during treadmill gait

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>This report presents a new imaging technique for non-invasive study of six degrees of freedom (DOF) knee kinematics during treadmill gait.</p> <p>Materials and methods</p> <p>A treadmill was integrated into a dual fluoroscopic imaging system (DFIS) to formulate a gait analysis system. To demonstrate the application of the system, a healthy subject walked on the treadmill at four different speeds (1.5, 2.0, 2.5 and 3.0 MPH) while the DFIS captured the knee motion during three strides under each speed. Characters of knee joint motion were analyzed in 6DOF during the treadmill walking.</p> <p>Results</p> <p>The speed of the knee motion was lower than that of the treadmill. Flexion amplitudes increased with increasing walking speed. Motion patterns in other DOF were not affected by increase in walking speed. The motion character was repeatable under each treadmill speed.</p> <p>Conclusion</p> <p>The presented technique can be used to accurately measure the 6DOF knee kinematics at normal walking speeds.</p

    Impact of Hospital Volume on the Economic Value of Computer Navigation for Total Knee Replacement

    No full text
    Background: An aim of the use of computer navigation is to reduce rates of revisions of total knee replacements by improving the alignment achieved at the surgery. However, the decision to adopt this technology may be difficult for some centers, especially low-volume centers, where the cost of purchasing this equipment may be high. The purpose of this study was to examine the impact of hospital volume on the cost-effectiveness of this new technology in order to determine its feasibility and the level of evidence that should be sought prior to its adoption
    corecore