197 research outputs found

    Characteristics of Metal Reduction During Prereduction of Chromite types of Ore

    Get PDF
    Iron and chromium were reduced from chromium spinel at 1300∘С and 1400∘С during 1 and 4 hours. The reduction was carried out with carbon or CO gas in one experiment simultaneously for six samples of three different types of ore. It was established that under these conditions, the CO gas neither reduces chromium nor iron from complex chromium spinel, whereas solid carbon reduces iron and chromium completely. In the mixture of solid reagents at the initial stage of reduction with solid carbon, the carbide shell was formed on the surface of carbon and oxide, accurately reproducing the surface topography of the particles. The formation of the shell indicated a countertransfer of the oxide substance to the surface of carbon and carbon substance to the surface of the oxide through the gas phase. The shell retarded and stopped the reduction process, however, when the shell substance was melted and drained, thereduction process continued. The same shell, but from the Fe–Cr non-carbon alloy, was formed on the surface of the single spinel crystals interspersed in a large volume of magnesium–silicate matrix. The results of the experiments were explained from the standpoint of the theory of the electron reduction mechanism developed by the authors with the formation of plasma in the gas gaps and its participation in the contactless electron-ion exchange between solid reagents. Keywords: metallization, ferrochrome, theory of reduction, low-temperature plasma, electron-ion exchang

    Studying microstructure and phase composition of a new complex calcium containing alloy

    Get PDF
    In the given article there are presented the results of studying the microstructure and phase structure of a complex alloy of alumosilicon with calcium. It is established that in the studied CAMS alloy active elements are present at a type of difficult intermetallid that positively influences quality of both ordinary, and qualitative brands of steel

    Analysis of X-ray whispering gallery waves propagating along liquid meniscuses

    Get PDF
    X-ray diffraction and fluorescence of whispering galleries (WGs) which propagate along meniscuses of deionized water or silicahydrosols enriched by CsOH have been analyzed for the first time. The measurements have been performed using the diffractometer with a moving tube-detector system. The X-ray beam rotation angle reached a maximum value of 4° on a silica hydrosol sample. The WG mode propagating near the surface of a concave meniscus as well as the fluorescence intensity have been found from a solution of the respective Helmholtz equations. For analysis of intensities of the X-ray scattering and fluorescence we have used a two-layer model of the liquid with the upper non-uniform corrugated layer in which the concentration of levitating Cs+ ions near the surface has a maximum derived from the experiment in the hydrosol depth of ~ 15 nm for SiO2particle sizes of ~ 5...7 nm. In order to determine the fluorescence intensity we have used the approach based on a method of fundamental parameters using the reciprocity theorem

    Kneadings, Symbolic Dynamics and Painting Lorenz Chaos. A Tutorial

    Full text link
    A new computational technique based on the symbolic description utilizing kneading invariants is proposed and verified for explorations of dynamical and parametric chaos in a few exemplary systems with the Lorenz attractor. The technique allows for uncovering the stunning complexity and universality of bi-parametric structures and detect their organizing centers - codimension-two T-points and separating saddles in the kneading-based scans of the iconic Lorenz equation from hydrodynamics, a normal model from mathematics, and a laser model from nonlinear optics.Comment: Journal of Bifurcations and Chaos, 201

    Condensation of Silica Nanoparticles on a Phospholipid Membrane

    Full text link
    The structure of the transient layer at the interface between air and the aqueous solution of silica nanoparticles with the size distribution of particles that has been determined from small-angle scattering has been studied by the X-ray reflectometry method. The reconstructed depth profile of the polarizability of the substance indicates the presence of a structure consisting of several layers of nanoparticles with the thickness that is more than twice as large as the thickness of the previously described structure. The adsorption of 1,2-distearoyl-sn-glycero-3-phosphocholine molecules at the hydrosol/air interface is accompanied by the condensation of anion silica nanoparticles at the interface. This phenomenon can be qualitatively explained by the formation of the positive surface potential due to the penetration and accumulation of Na+ cations in the phospholipid membrane.Comment: 7 pages, 5 figure

    Vortex core size in interacting cylindrical nanodot arrays

    Full text link
    The effect of dipolar interactions among cylindrical nanodots, with a vortex-core magnetic configuration, is analyzed by means of analytical calculations. The cylinders are placed in a N x N square array in two configurations - core oriented parallel to each other and with antiparallel alignment between nearest neighbors. Results comprise the variation in the core radius with the number of interacting dots, the distance between them and dot height. The dipolar interdot coupling leads to a decrease (increase) of the core radius for parallel (antiparallel) arrays

    11C-Choline Pet/Ct in the Detection of Prostate Cancer Relapse in Patients After Radical Treatment With Psa Level < 10 Ng/Ml

    Get PDF
    Purpose: To evaluate the usefulness of 11C-Choline PET/CT in the detection of recurrent prostate cancer (PCa) in patients with biochemical relapse after radical treatment. Materials and methods: This retrospective study included 217 PCa patients who underwent 11C-Choline PET/CT in the Department of Nuclear Medicine of Bakoulev Scientific Centre. All patients had biochemical relapse 3±2 years after radical treatment for locally advanced PCa (T1–3 N0–1 M0): radical prostatectomy (n = 159) and radiation therapy (n = 58). The mean PSA value in the group was 2.1±2.5 (0.2–9.7) ng/ml, median – 1.9 ng/ml. Imaging was performed on PET/CT scanner (Biograph-64, Siemens) 10 min after injection of 11C-Choline (400–550 Mbq). Results: Overall, according to 11C-Choline PET/CT results PCa relapse was detected in 56% (121/217) of cases: in 50% (80/159) after radical prostatectomy and in 71% (41/58) after radiation therapy. The mean PSA value in PET-positive cases was 3.1±2.2 (0.2–9.7) ng/ml, while in PETnegative cases – 1.8±1.7 (0.2–4.6) ng/ml. The majority – 68% (65/96) patients with PET-negative scan had low PSA levels (&lt; 2 ng/ml). PET/CT results were positive in 43% (50/115) patients with PSA of &lt; 2 ng/ml, in 63% (45/72) with PSA of 2 to 5 ng/ml, and in 87% (26/30) with PSA of &gt; 5 ng/ml. Local relapse was detected in 51% (62/121) patients, distant metastases – in 28% (34/121) of cases, both local and distant metastases – in 21% (25/121) of cases. Lymph node metastases were detected in 38% (86/217) of all patients included in the analysis, of which 28% (24/86) had lesions in lymph node of normal size (median 7 mm). Of all PET-positive patients bone metastases were detected in 33% (40/121), of which 60% (24/40) had isolated skeletal involvement. Importantly, that 27% (11/40) of PETpositive patients with bone metastases had no structural abnormalities on CT images (CT-negative cases), corresponding to isolated involvement of bone marrow. And half of these CT-negative patients (5/11) had single lesions. The mean PSA value in patients with bone metastases was 5.0±3.7 (0.4–9.1) ng/ml, median – 3.8 ng/ml. According to 11C-Choline PET/CT results oligometastatic PCa recurrence was revealed in 38% (82/217) of all patients, of which 62% (51/82) had local relapse only. Distant oligometastatic lesions were detected in 38% (31/82), of which 13% (4/31) were presented by normal-size lymph nodes and 19% (6/31) – by early bone marrow metastases. 48% (58/121) of PET-positive results were confirmed by data of repeated PET/CT examinations. Conclusion: 11C-Choline PET/CT has been shown to be a single noninvasive accurate technique for detection of recurrent PCa in patients with rising PSA after radical treatment, which allows to differentiate patients with local and distant metastases in one study, as well as identify oligometastatic process, and therefore was useful in determining the further personalized therapeutic approach. Keywords: prostate cancer, PET/CT, 11C-Choline, biochemical recurrence, PSA

    LOCAL RECURRENCE OF TUBULOCYSTIC CARCINOMA 4 YEARS AFTER RENAL RESECTION (A CLINICAL OBSERVATION)

    Get PDF
    The paper describes a clinical case of a local recurrence of tubulocystic carcinoma (TCC) in a 46-year-old man, a relatively good course (the relapse occurred after 4 years), who has been successfully operated on and is being followed up. This disease is a rare renal malignancy and, until recently, it has been referred to as collecting tubular carcinoma. However, this disease has come to be regarded as an independent nosological entity, by taking into account its certain morphological, immunohistohemical, and cytogenetic characteristics, as well as the nature of its course. About 80 TCC cases have been described to date. Further study of this disease and other rare renal malignancies will allow the more accurate elaboration of management tactics for such patients in terms of certain prognostic factors, which calls for a larger number of cases of this disease
    corecore