450 research outputs found

    Effect of decontamination and cleaning on the shear bond strength of high translucency zirconia

    Get PDF
    (1) Background: This study evaluated the bonding performance of high translucency zirconia after diverse surficial decontamination and cleaning procedures. (2) Methods: High translucency zirconia (LavaTM Esthetic) specimens (2.0 mm × 20 mm × 10 mm) were exposed to different surface treatments prior to bonding to CoCr cylinders (d = 5 mm, height = 3 mm). All surfaces were sandblasted (40 µm aluminum oxide, 2 bar) and treated with alcohol (al), saliva (s), saliva + water (sw), or saliva + NaOCl + water (sn) before bonding was performed with the following adhesive luting systems: RelyXTM Unicem 2 (RX), ScotchbondTM Universal (SBU) + RelyXTM Ultimate (RU) or Monobond Plus (MP) + Multilink® Automix (ML). After 24 h, thermocycling (TC:12,000 × 5 °C/55 °C) and 90 days of storage at 37 °C in distilled water, the shear bond strength (SBS) was evaluated according to ISO/TS 11,405:2015. Failure modes along bonding areas were characterized. Means and standard deviations (n = 10 per group) were determined and statistically analyzed with one-way ANOVA/Bonferroni (α = 0.05). (3) Results: The SBS after 24 h varied between 3.5 (sRX) and 69.4 MPa (snMP + ML). Values from 0 (sRX) to 70.3 MPa (swRX) were found after TC. Data after 90 days of storage showed the lowest values for sRX (0 MPa) and the highest values for alSBU + RU (75.5 MPa). Adhesive failure was noted at all aging conditions. (4) Conclusions: SBU + RU or RX and MP + ML including saliva decontamination of the ceramic surface with water or NaOCl + water allow efficient bonding to LavaTM Esthetic

    Development of a device to simulate tooth mobility

    Get PDF
    Objectives: The testing of new materials under simulation of oral conditions is essential in medicine. For simulation of fracture strength different simulation devices are used for test set-up. The results of these in vitro tests differ because there is no standardization of tooth mobility in simulation devices. The aim of this study is to develop a simulation device that depicts the tooth mobility curve as accurately as possible and creates reproducible and scalable mobility curves. Materials and methods: With the aid of published literature and with the help of dentists, average forms of tooth classes were generated. Based on these tooth data, different abutment tooth shapes and different simulation devices were designed with a CAD system and were generated with a Rapid Prototyping system. Then, for all simulation devices the displacement curves were created with a universal testing machine and compared with the tooth mobility curve. With this new information, an improved adapted simulation device was constructed. Results: A simulations device that is able to simulate the mobility curve of natural teeth with high accuracy and where mobility is reproducible and scalable was developed

    CAD/CAM Resin-Based Composites for Use in Long-Term Temporary Fixed Dental Prostheses

    Get PDF
    The aim of this in vitro study was to analyse the performance of CAD/CAM resin-based composites for the fabrication of long-term temporary fixed dental prostheses (FDP) and to compare it to other commercially available alternative materials regarding its long-term stability. Four CAD/CAM materials [Structur CAD (SC), VITA CAD-Temp (CT), Grandio disc (GD), and Lava Esthetic (LE)] and two direct RBCs [(Structur 3 (S3) and LuxaCrown (LC)] were used to fabricate three-unit FDPs. 10/20 FDPs were subjected to thermal cycling and mechanical loading by chewing simulation and 10/20 FDPs were stored in distilled water. Two FDPs of each material were forwarded to additional image diagnostics prior and after chewing simulation. Fracture loads were measured and data were statistically analysed. SC is suitable for use as a long-term temporary (two years) three-unit FDP. In comparison to CT, SC featured significantly higher breaking forces (SC > 800 N; CT < 600 N) and the surface wear of the antagonists was (significantly) lower and the abrasion of the FDP was similar. The high breaking forces (1100–1327 N) of GD and the small difference compared to LE regarding flexural strength showed that the material might be used for the fabrication of three-unit FDPs. With the exception of S3, all analysed direct or indirect materials are suitable for the fabrication of temporary FDPs

    Thermoanalytical Investigations on the Influence of Storage Time in Water of Resin-Based CAD/CAM Materials

    Get PDF
    New resin-based composites and resin-infiltrated ceramics are used to fabricate computer-aided design (CAD) and computer-aided manufacturing (CAM)-based restorations, although little information is available on the long-term performance of these materials. The aim of this investigation was to determine the effects of storage time (24 h, 90 days, 180 days) on the thermophysical properties of resin-based CAD/CAM materials. Thermogravimetric Analysis (TGA), differential scanning calorimetry (DSC) and dynamic mechanical analysis (DMA) were used in the study. TGA provided insight into the composition of the resin-based materials and the influence of internal plasticization and water sorption. Resin-based composites showed different decomposition, heat energy and mechanical behavior, which was influenced by storage time in water. Individual materials such as Grandio bloc showed lower influence of water storage while maintaining good mechanical properties

    Impact of simulated reduced alveolar bone support, increased tooth mobility, and distal post-supported, root-treated abutment tooth on load capability of all-ceramic zirconia-supported cantilever FDP

    Get PDF
    OBJECTIVES The aim of this in vitro study was an analysis of the impact of simulated reduced alveolar bone support and post-restored, endodontically treated distal abutment tooth on load capability of all-ceramic zirconia-based cantilever-fixed dental prosthesis (CFDP). MATERIAL AND METHODS The roots of human lower sound premolars (n = 80) were divided into five experimental groups to be restored with all-ceramic zirconia-supported three-unit CFDP regarding bone loss (BL) relative to the cement-enamel junction (CEJ): 2 mm below CEJ = 0% BL (control group), group 25% distal BL, group 50% distal BL, group 50% mesial and distal BL, and group 50% distal BL and adhesive post-supported restoration. Specimens were exposed to simulated clinical function by thermo-mechanical loading (6.000 cycles 5°-55°; 1.2 × 10 cycles 0-50 N) and subsequent linear loading until failure. RESULTS Tooth mobility increased significantly for groups with simulated bone loss (p < 0.001). Four specimens failed during thermal cycling and mechanical loading (TCML). The maximum load capability ranged from 350 to 569 N, and did not differ significantly between experimental groups (p = 0.095). Groups with simulated bone loss revealed more tooth fractures at distal abutment teeth, whereas technical failures were more frequent in the control group (p = 0.024). CONCLUSIONS Differences of alveolar bone support and respectively increased tooth mobility between mesial and distal abutments did not influence load capability. A distal adhesively post-and-core-supported, root-treated abutment tooth did not increase risk of three-unit CFDP failure. CLINICAL RELEVANCE CFDPs are a treatment option used with caution when reduced alveolar bone support, increased tooth mobility, and distal post-supported, root-treated abutment teeth are involved

    An Overview of Clinical Studies on Fiber Post Systems

    Get PDF
    Intraradicular posts are useful adjuncts in the restoration of endodontically treated teeth. These systems have undergone a significant evolution in recent years, and fiber-reinforced systems have started to be incorporated into routine clinical care more frequently. Despite the high number of laboratory studies pertaining to the characteristics of fiber posts, clinical studies evaluating their general success rates are rather limited. Since clinical investigations are reliable means to achieve information about the general behavior pattern of materials or techniques, assessment of this data will be beneficial to have a better understanding of fiber-reinforced intraradicular post systems. The purpose of this paper was to make a summary of clinical studies regarding various fiber posts. A PubMed search was conducted and articles dating back to 1990 were retrieved. The paper provides an overview of clinical studies on fiber posts specifically in the last decade as well as commentary analysis

    The Influence of Surface Preparation, Chewing Simulation, and Thermal Cycling on the Phase Composition of Dental Zirconia

    Get PDF
    The effect of dental technical tools on the phase composition and roughness of 3/4/5 yttria-stabilized tetragonal zirconia polycrystalline (3y-/4y-/5y-TZP) for application in prosthetic dentistry was investigated. Additionally, the X-ray diffraction methods of Garvie-Nicholson and Rietveld were compared in a dental restoration context. Seven plates from two manufacturers, each fabricated from commercially available zirconia (3/4/5 mol%) for application as dental restorative material, were stressed by different dental technical tools used for grinding and polishing, as well as by chewing simulation and thermocycling. All specimens were examined via laser microscopy (surface roughness) and X-ray diffraction (DIN EN ISO 13356 and the Rietveld method). As a result, the monoclinic phase fraction was halved by grinding for the 3y-TZP and transformed entirely into one of the tetragonal phases by polishing/chewing for all specimens. The tetragonal phase t is preferred for an yttria content of 3 mol% and phase t″ for 5 mol%. Mechanical stress, such as polishing or grinding, does not trigger low-temperature degradation (LTD), but it fosters a phase transformation from monoclinic to tetragonal under certain conditions. This may increase the translucency and deteriorate the mechanical properties to some extent
    • …
    corecore