    In vitro evaluation of electrospun blends of gelatin and PCL for application as a partial thickness corneal graft

    Get PDF
    The advent of innovative surgical procedures utilizing partial thickness corneal grafts has created a need for the development of synthetic implants to recreate corneal stromal tissue. This work evaluates electrospun gelatin and polycaprolactone (PCL) scaffolds as a potential biomaterial suitable for use in regeneration of corneal stromal tissue. Electrospun gelatin has been used for many years in tissue engineering, however, post‐production modification, such as crosslinking, is usually required to mechanically strengthen such scaffolds. This paper aims therefore to compare glutaraldehyde (GA) cross‐linked electrospun gelatin scaffolds with electrospun blends of gelatin and PCL at different ratios. Scaffolds were fabricated using electrospinning and characterized by scanning electron microscopy, Attenuated Total Reflectance‐Fourier Transform Infrared Spectroscopy (ATR‐FTIR), and tensile testing. To evaluate biocompatibility, primary human corneal stromal cells (hCSC) were seeded upon the scaffolds to assess adherence, proliferation and phenotype. Results demonstrated that scaffolds fabricated from mixtures of gelatin and PCL showed increased mechanical strength and plasticity compared to scaffolds fabricated from GA cross‐linked gelatin alone. In addition, scaffolds fabricated from PCL and gelatin showed comparable support of hCSC adhesion and proliferation. In conclusion, blended mixtures of gelatin and PCL can be considered as an option in the selection of corneal repair materials in the future

    The Effect of a Type I Photoinitiator on Cure Kinetics and Cell Toxicity in Projection-Microstereolithography

    Get PDF
    AbstractProjection-microstereolithography is an additive manufacturing technique based on the spatially controlled solidification of a liquid photopolymer on exposure to digitally manipulated light patterns. This study presents a methodology to evaluate the effect of a type-I photoinitiator on the reaction kinetics in the process and the cytocompatibility of the produced components. While the reaction speed and degree of conversion were heavily dependent on the applied amount of the initiator, a clear toxic effect was observed with all tested concentrations, and a post-processing step of 7 days was required to leach out the initiator residues

    Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures

    Get PDF
    Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo

    Delivery systems for bone growth factors - the new players in skeletal regeneration

    No full text
    Given the challenge of an increasing elderly population, the ability to repair and regenerate traumatised or lost tissue is a major clinical and socio-economic need. Pivotal in this process will be the ability to deliver appropriate growth factors in the repair cascade in a temporal and tightly regulated sequence using appropriately designed matrices and release technologies within a tissue engineering strategy. This review outlines the current concepts and challenges in growth factor delivery for skeletal regeneration and the potential of novel delivery matrices and biotechnologies to influence the healthcare of an increasing ageing population

    Evaluation of skeletal tissue repair, Part 2: Enhancement of skeletal tissue repair through dual-growth-factor-releasing hydrogels within an ex vivo chick femur defect model

    No full text
    There is an unmet need for improved, effective tissue engineering strategies to replace or repair bone damaged through disease or injury. Recent research has focused on developing biomaterial scaffolds capable of spatially and temporally releasing combinations of bioactive growth factors, rather than individual molecules, to recapitulate repair pathways present in vivo. We have developed an ex vivo embryonic chick femur critical size defect model and applied the model in the study of novel extracellular matrix (ECM) hydrogel scaffolds containing spatio-temporal combinatorial growth factor-releasing microparticles and skeletal stem cells for bone regeneration. Alginate/bovine bone ECM (bECM) hydrogels combined with poly(d,l-lactic-co-glycolic acid) (PDLLGA)/triblock copolymer (10-30% PDLLGA-PEG-PLDLGA) microparticles releasing dual combinations of vascular endothelial growth factor (VEGF), chondrogenic transforming growth factor beta 3 (TGF-?3) and the bone morphogenetic protein BMP2, with human adult Stro-1+bone marrow stromal cells (HBMSCs), were placed into 2mm central segmental defects in embryonic day 11 chick femurs and organotypically cultured. Hydrogels loaded with VEGF combinations induced host cell migration and type I collagen deposition. Combinations of TGF-?3/BMP2, particularly with Stro-1+HBMSCs, induced significant formation of structured bone matrix, evidenced by increased Sirius red-stained matrix together with collagen expression demonstrating birefringent alignment within hydrogels. This study demonstrates the successful use of the chick femur organotypic culture system as a high-throughput test model for scaffold/cell/growth factor therapies in regenerative medicine. Temporal release of dual growth factors, combined with enriched Stro-1+HBMSCs, improved the formation of a highly structured bone matrix compared to single release modalities. These studies highlight the potential of a unique alginate/bECM hydrogel dual growth factor release platform for bone repair

    Evaluation of skeletal tissue repair, Part 1: Assessment of novel growth-factor-releasing hydrogels in an ex vivo chick femur defect model

    No full text
    Current clinical treatments for skeletal conditions resulting in large-scale bone loss include autograft or allograft, both of which have limited effectiveness. In seeking to address bone regeneration, several tissue engineering strategies have come to the fore, including the development of growth factor releasing technologies and appropriate animal models to evaluate repair. Ex vivo models represent a promising alternative to simple in vitro systems or complex, ethically challenging in vivo models. We have developed an ex vivo culture system of whole embryonic chick femora, adapted in this study as a critical size defect model to investigate the effects of novel bone extracellular matrix (bECM) hydrogel scaffolds containing spatio-temporal growth factor-releasing microparticles and skeletal stem cells on bone regeneration, to develop a viable alternative treatment for skeletal degeneration. Alginate/bECM hydrogels combined with poly (d,l-lactic-co-glycolic acid) (PDLLGA)/triblock copolymer (10-30% PDLLGA-PEG-PDLLGA) microparticles releasing VEGF, TGF-?3 or BMP-2 were placed, with human adult Stro-1+ bone marrow stromal cells, into 2mm central segmental defects in embryonic chick femurs. Alginate/bECM hydrogels loaded with HSA/VEGF or HSA/TGF-?3 demonstrated a cartilage-like phenotype, with minimal collagen I deposition, comparable to HSA-only control hydrogels. The addition of BMP-2 releasing microparticles resulted in enhanced structured bone matrix formation, evidenced by increased Sirius red-stained matrix and collagen expression within hydrogels. This study demonstrates delivery of bioactive growth factors from a novel alginate/bECM hydrogel to augment skeletal tissue formation and the use of an organotypic chick femur defect culture system as a high-throughput test model for scaffold/cell/growth factor therapies for regenerative medicine
    corecore