12 research outputs found

    Neonatal warming devices: What can be recommended for low-resource settings when skin-to-skin care is not feasible?

    Get PDF
    Hypothermia occurs frequently among clinically unstable neonates who are not suitable to place in skin-to-skin care. This study aims to explore the existing evidence on the effectiveness, usability, and affordability of neonatal warming devices when skin-to-skin care is not feasible in low-resource settings. To explore existing data, we searched for (1) systematic reviews as well as randomised and quasi-randomised controlled trials comparing the effectiveness of radiant warmers, conductive warmers, or incubators among neonates, (2) neonatal thermal care guidelines for the use of warming devices in low-resource settings and (3) technical specification and resource requirement of warming devices which are available in the market and certified medical device by the US Food and Drug Administration or with a CE marking. Seven studies met the inclusion criteria, two were systematic reviews comparing radiant warmers vs. incubators and heated water-filled mattresses vs. incubators, and five were randomised controlled trials comparing conductive thermal mattresses with phase-change materials vs. radiant warmers and low-cost cardboard incubator vs. standard incubator. There was no significant difference in effectiveness between devices except radiant warmers caused a statistically significant increase in insensible water loss. Seven guidelines covering the use of neonatal warming devices show no consensus about the choice of warming methods for clinically unstable neonates. The main warming devices currently available and intended for low-resource settings are radiant warmers, incubators, and conductive warmers with advantages and limitations in terms of characteristics and resource requirements. Some devices require consumables which need to be considered when making a purchase decision. As effectiveness is comparable between devices, specific requirements according to patients' characteristics, technical specification, and context suitability must play a primary role in the selection and purchasing decision of warming devices. In the delivery room, a radiant warmer allows fast access during a short period and will benefit numerous neonates. In the neonatal unit, warming mattresses are low-cost, effective, and low-electricity consumption devices. Finally, incubators are required for very premature infants to control insensible water losses, mainly during the first one to two weeks of life, mostly in referral centres

    Challenges and opportunities in neonatal sepsis management: insights from a survey among clinicians in 25 Sub-Saharan African countries.

    Get PDF
    BACKGROUND Neonatal sepsis (NS) is a global health issue, particularly in Sub-Saharan Africa, where it accounts for a substantial portion of neonatal morbimortality. This multicountry survey aimed to elucidate current practices, challenges and case definitions in managing NS among clinicians in Sub-Saharan Africa. METHODS The survey targeted physicians and medical practitioners working in neonatal care who participated in a Self-Administered Web Questionnaire. The main objective was to understand NS and infection case definitions and management from the clinician's point of view and to identify challenges and opportunities in sepsis management. Participants were queried on demographics, definitions and diagnostic criteria, treatment approaches, and infection prevention and control (IPC) measures. A total of 136 participants from 93 healthcare structures responded, providing valuable insights into NS management practices. RESULTS From May to July 2022 across 21 Sub-Saharan African countries, 136 neonatal clinicians with an average from 93 structures with on average 10-year experience took the survey. NS ranked highest among prevalent neonatal conditions. Diagnostic case definitions between sepsis and infection were attributed to clinical signs, anamnesis, C reactive protein, white blood cll count and blood cultures with no statistically significant differences. Early-onset sepsis was defined within 72 hours by 48%, while late-onset varied. Antibiotics were likely on admission (86.4%) and during the stay (82.2%). Treatment abandonment was reported unlikely. The preferred antibiotic regimen for early-onset sepsis was intravenous amoxicillin (or ampicillin), gentamycin and cefotaxime. Blood culture availability and IPC protocols were reported as limited, particularly concerning patient environment, pharmacy protocols and clean-dirty circuits. CONCLUSIONS This NS survey emphasises clinicians' challenges due to limited access to diagnostic tools and raises concerns about antimicrobial overexposure. IPC also seem limited, according to participants. Addressing these challenges can enhance diagnostic practices, antibiotic stewardship and infection control in the region

    Understanding Neonatal sepsis in sub saharan africa - an online survey

    No full text
    AbstractNeonatal sepsis poses a significant global health threat, particularly in Sub-Saharan Africa, where it accounts for a substantial portion of neonatal morbimortality. This multicentre survey aimed to elucidate current practices, challenges, and definitions in managing neonatal sepsis among clinicians in Sub-Saharan Africa. The survey targeted physicians and medical practitioners directly involved in neonatal care who participated to a self-administered web questionnaire. The main objective was to understand sepsis and infection definitions and management from the clinician’s point of view and identify challenges and opportunities in sepsis management. Participants were queried on demographics, definitions and diagnostic criteria, treatment approaches, and infection prevention and control measures

    Understanding Neonatal Sepsis

    No full text
    Project Understanding Neonatal Sepsis in Sub Saharan Africa, an online survey with neonatal physicians

    Neonatal warming devices : What can be recommended for low-resource settings when skin-to-skin care is not feasible ?

    No full text
    Hypothermia occurs frequently among clinically unstable neonates who are not suitable to place in skin-to-skin care. This study aims to explore the existing evidence on the effectiveness, usability, and affordability of neonatal warming devices when skin-to-skin care is not feasible in low-resource settings. To explore existing data, we searched for (1) systematic reviews as well as randomised and quasi-randomised controlled trials comparing the effectiveness of radiant warmers, conductive warmers, or incubators among neonates, (2) neonatal thermal care guidelines for the use of warming devices in low-resource settings and (3) technical specification and resource requirement of warming devices which are available in the market and certified medical device by the US Food and Drug Administration or with a CE marking. Seven studies met the inclusion criteria, two were systematic reviews comparing radiant warmers vs. incubators and heated water-filled mattresses vs. incubators, and five were randomised controlled trials comparing conductive thermal mattresses with phase-change materials vs. radiant warmers and low-cost cardboard incubator vs. standard incubator. There was no significant difference in effectiveness between devices except radiant warmers caused a statistically significant increase in insensible water loss. Seven guidelines covering the use of neonatal warming devices show no consensus about the choice of warming methods for clinically unstable neonates. The main warming devices currently available and intended for low-resource settings are radiant warmers, incubators, and conductive warmers with advantages and limitations in terms of characteristics and resource requirements. Some devices require consumables which need to be considered when making a purchase decision. As effectiveness is comparable between devices, specific requirements according to patients' characteristics, technical specification, and context suitability must play a primary role in the selection and purchasing decision of warming devices. In the delivery room, a radiant warmer allows fast access during a short period and will benefit numerous neonates. In the neonatal unit, warming mattresses are low-cost, effective, and low-electricity consumption devices. Finally, incubators are required for very premature infants to control insensible water losses, mainly during the first one to two weeks of life, mostly in referral centres

    Post-burn infantile hemangioma in an extremely premature neonate

    No full text
    Infantile hemangioma (IH) is the most common vascular tumor in infancy, and its physiopathology is not fully understood. Nevertheless, a hypoxic insult may be an essential element for the formation of an IH. Herein, we describe a case of a 25-week premature newborn who developed an IH after a post-burn scar and its evolution

    Safety of Red Blood Cell Transfusion Using Small Central Lines in Neonates: An in vitro Non-inferiority Study

    No full text
    Aim: This study aimed to investigate the safety of transfusing red blood cell concentrates (RBCCs) through small [24 gauge (24G)] and extra-small [28 gauge [28G)] peripherally inserted central catheters (PICCs), according to guidelines of transfusion practice in Switzerland. Methods: We performed a non-inferiority in vitro study to assess the safety of transfusing RBCC for 4 h at a 4 ml/h speed through 24G silicone and 28G polyurethane PICC lines, compared with a peripheral 24G short catheter. The primary endpoint was hemolysis percentage. Secondary endpoints were catheter occlusion, inline pressure, and potassium and lactate values. Results: For the primary outcome, hemolysis values were not statistically different among catheter groups (0.06% variation, p = 0.95) or over time (2.75% variation, p = 0.72). The highest hemolysis values in both 24G and 28G PICCs were below the non-inferiority predefined margin. We did not observe catheter occlusion. Inline pressure varied between catheters but followed the same pattern of rapid increase followed by stabilization. Potassium and lactate measurements were not statistically different among tested catheters (0.139% variation, p = 0.98 for potassium and 0.062%, p = 0.96 for lactates). Conclusions: This study shows that RBCC transfusion performed in vitro through 24G silicone and 28G polyurethane PICC lines is feasible without detectable hemolysis or pressure concerns. Also, it adds that, concerning hemolysis, transfusion of RBCC in small and extra-small PICC lines is non-inferior to peripheral short 24G catheters. Clinical prospective assessment in preterm infants is needed to confirm these data further

    Clinical detection of 'cold stress' is overlooked : an online survey of healthcare workers to explore the gap in neonatal thermal care in low-resource settings

    No full text
    Background: Neonatal hypothermia has been widely regarded as a major contributory factor to neonatal mortality and morbidity in low-resource settings. The high prevalence of potentially preventable hypothermia today urges an investigation into why neonates still become hypothermic despite awareness of the problem and established thermal care guidelines. This study aimed to explore the gaps in knowledge and practices of neonatal thermal care among healthcare workers in low-resource settings. Methods: A cross-sectional, questionnaire-based survey was performed online among healthcare workers in low-resource settings. We applied a purposive and snowballing sampling method to recruit participants through a two-round international online survey. Questionnaires were developed using themes of neonatal thermal care extracted from existing neonatal care guidelines. Results: 55 neonatal care professionals participated in the first-round survey and 33 in the second. Almost all participants (n=44-54/55) acknowledged the importance of the WHO's warm chain to keep a neonate warm. However, fewer participants (n=34-46/55) responded to practice them. When asked about cold stress, defined as a condition in which neonates are below optimum environmental temperature and using more oxygen and energy while maintaining normal body temperature, 15 out of 55 participants answered that checking extremity temperatures by hand touch was useless. Some participants reported concern about the extremity temperature's inaccuracy compared with core temperature. Opinions and preferences for rewarming methods differed among participants, and so did the availability of warming equipment at their institutions. Conclusion: An inadequate understanding of cold stress underestimates the potential benefits of extremity temperatures and leads to missed opportunities for the timely prevention of hypothermia. The current thermal care guidelines fail to highlight the importance of monitoring cold stress and intervening before hypothermia occurs. Therefore, we urge introducing the concept of cold stress in any neonatal thermal care guidelines.</p

    Clinical detection of 'cold stress' is overlooked: an online survey of healthcare workers to explore the gap in neonatal thermal care in low-resource settings

    No full text
    Background Neonatal hypothermia has been widely regarded as a major contributory factor to neonatal mortality and morbidity in low-resource settings. The high prevalence of potentially preventable hypothermia today urges an investigation into why neonates still become hypothermic despite awareness of the problem and established thermal care guidelines. This study aimed to explore the gaps in knowledge and practices of neonatal thermal care among healthcare workers in low-resource settings.Methods A cross-sectional, questionnaire-based survey was performed online among healthcare workers in low-resource settings. We applied a purposive and snowballing sampling method to recruit participants through a two-round international online survey. Questionnaires were developed using themes of neonatal thermal care extracted from existing neonatal care guidelines.Results 55 neonatal care professionals participated in the first-round survey and 33 in the second. Almost all participants (n=44-54/55) acknowledged the importance of the WHO's warm chain to keep a neonate warm. However, fewer participants (n=34-46/55) responded to practice them. When asked about cold stress, defined as a condition in which neonates are below optimum environmental temperature and using more oxygen and energy while maintaining normal body temperature, 15 out of 55 participants answered that checking extremity temperatures by hand touch was useless. Some participants reported concern about the extremity temperature's inaccuracy compared with core temperature. Opinions and preferences for rewarrning methods differed among participants, and so did the availability of warming equipment at their institutions.Conclusion An inadequate understanding of cold stress underestimates the potential benefits of extremity temperatures and leads to missed opportunities for the timely prevention of hypothermia. The current thermal care guidelines fail to highlight the importance of monitoring cold stress and intervening before hypothermia occurs. Therefore, we urge introducing the concept of cold stress in any neonatal thermal care guidelines.VD

    A minimal neonatal dataset (mND) for low- and middle-income countries as a tool to record, analyse, prevent and follow-up neonatal morbidity and mortality

    No full text
    # Background Neonatal mortality accounts for the most significant and today increasing proportion of under-5 mortality, especially in sub-Saharan Africa. The neonatal population is a sharp target for intervention for these 2.5 million annual deaths. The limited availability of quality data on morbidities leading up to this mortality hampers the development and follow-up of effective interventions. For leverage, undoubtedly more detailed and standardized data adapted to low and middle-income countries (LMICs) is urgently needed. # Methods Drawing on existing databases such as the Swiss Neonatal Network and Vermont Oxford Network, 267 clinical, administrative, and structural variables of neonatal health and healthcare services were selected and submitted for ranking to 42 experts through two Delphi rounds. An empirically limited number of variables with the highest ranking for availability and relevance in low and middle-income countries were field-tested in three centres in Burkina Faso during one year for improvement and practicality. # Results We report the database development process according to the Standards for Quality Improvement Reporting Excellence (SQUIRE 2.0) recommendations. The final dataset is composed of 73 clinical and 6 administrative patient variables, and 21 structural healthcare center variables. Two-thirds of clinical variables maintain matching definitions with high-income countries. # Conclusions The developed minimal neonatal dataset is standardized and field-tested for relevance and availability in LMICs allowing south-south and some south-north cross-comparison
    corecore