5 research outputs found

    The impact of a simulated intervention on attitudes of undergraduate nursing and medical students towards end of life care provision

    Get PDF
    BACKGROUND: The concerns of undergraduate nursing and medical students’ regarding end of life care are well documented. Many report feelings of emotional distress, anxiety and a lack of preparation to provide care to patients at end of life and their families. Evidence suggests that increased exposure to patients who are dying and their families can improve attitudes toward end of life care. In the absence of such clinical exposure, simulation provides experiential learning with outcomes comparable to that of clinical practice. The aim of this study was therefore to assess the impact of a simulated intervention on the attitudes of undergraduate nursing and medical students towards end of life care. METHODS: A pilot quasi-experimental, pretest-posttest design. Attitudes towards end of life care were measured using the Frommelt Attitudes Towards Care of the Dying Part B Scale which was administered pre and post a simulated clinical scenario. 19 undergraduate nursing and medical students were recruited from one large Higher Education Institution in the United Kingdom. RESULTS: The results of this pilot study confirm that a simulated end of life care intervention has a positive impact on the attitudes of undergraduate nursing and medical students towards end of life care (p < 0.001). CONCLUSIONS: Active, experiential learning in the form of simulation teaching helps improve attitudes of undergraduate nursing and medical students towards end of life. In the absence of clinical exposure, simulation is a viable alternative to help prepare students for their professional role regarding end of life care

    Display of Cell Surface Sites for Fibronectin Assembly Is Modulated by Cell Adherence to 1F3 and C-Terminal Modules of Fibronectin

    Get PDF
    BACKGROUND: Fibronectin-null cells assemble soluble fibronectin shortly after adherence to a substrate coated with intact fibronectin but not when adherent to the cell-binding domain of fibronectin (modules (7)F3-(10)F3). Interactions of adherent cells with regions of adsorbed fibronectin other than modules (7)F3-(10)F3, therefore, are required for early display of the cell surface sites that initiate and direct fibronectin assembly. METHODOLOGY/PRINCIPAL FINDINGS: To identify these regions, coatings of proteolytically derived or recombinant pieces of fibronectin containing modules in addition to (7)F3-(10)F3 were tested for effects on fibronectin assembly by adherent fibronectin-null fibroblasts. Pieces as large as one comprising modules (2)F3-(14)F3, which include the heparin-binding and cell adhesion domains, were not effective in supporting fibronectin assembly. Addition of module (1)F3 or the C-terminal modules to modules (2)F3-(14)F3 resulted in some activity, and addition of both (1)F3 and the C-terminal modules resulted in a construct, (1)F3-C, that best mimicked the activity of a coating of intact fibronectin. Constructs (1)F3-C V0, (1)F3-C V64, and (1)F3-C Delta(V(15)F3(10)F1) were all able to support fibronectin assembly, suggesting that (1)F3 through (11)F1 and/or (12)F1 were important for activity. Coatings in which the active parts of (1)F3-C were present in different proteins were much less active than intact (1)F3-C. CONCLUSIONS: These results suggest that (1)F3 acts together with C-terminal modules to induce display of fibronectin assembly sites on adherent cells

    A New Technique for Radiographic Measurement of Acetabular Cup Orientation

    No full text
    Accurate radiographic measurement of acetabular cup orientation is required in order to assess susceptibility to impingement, dislocation, and edge loading wear. In this study, the accuracy and precision of a new radiographic cup orientation measurement system were assessed and compared to those of two commercially available systems. Two types of resurfacing hip prostheses and an uncemented prosthesis were assessed. Radiographic images of each prosthesis were created with the cup set at different, known angles of version and inclination in a measurement jig. The new system was the most accurate and precise and could repeatedly measure version and inclination to within a fraction of a degree. In addition it has a facility to distinguish cup retroversion from anteversion on anteroposterior radiographs

    Students' participation in collaborative research should be recognised

    No full text
    Letter to the editor
    corecore