38 research outputs found

    Delayed-Onset Transient Light Sensitivity Syndrome after Corneal Collagen Cross-Linking: A Case Series

    Get PDF
    In this case series, we report a potentially novel association of corneal collagen crosslinking (CCL) with the development of photophobia symptoms in a series of patients at a tertiary ophthalmology clinic and describe their clinical course. Photosensitivity is a rare and seemingly unpredictable complication of refractive surgery but can present as a disabling, bilateral ocular pain that requires immediate treatment. This complication, termed transient light-sensitivity syndrome (TLSS), can have a substantially delayed presentation after ocular procedures and is associated with inflammation of structures in the anterior chamber that can be imperceptible on slit-lamp examination. Traditionally, exposure to high-energy femtosecond lasers is hypothesized to create stromal gas bubbles powering postoperative inflammatory reactions. TLSS-like symptoms after CCL may be due to a secondary inflammatory response involving activated keratocytes and cytokine release. However, free radical damage from the interaction of riboflavin and ultraviolet in CCL may also drive this inflammatory process

    Keratoconus in a patient with Alport syndrome: A case report

    Get PDF
    BACKGROUND Known ocular manifestations of Alport syndrome include features such as anterior lenticonus and fleck retinopathy. Reports of keratoconus in such patients are limited. We report tomographic findings consistent with keratoconus in a patient with Alport syndrome. CASE SUMMARY A 52-year-old female was referred to our ophthalmology clinic with decreased vision and increased tearing. She was diagnosed with stage III Alport syndrome two years prior. Upon examination she was found to have average keratometries of 48 D bilaterally with tomographic evidence of keratoconus. CONCLUSION Although a rare presentation, concurrent Alport syndrome and keratoconus should be considered when reviewing the ocular health of Alport syndrome patients and appropriate management steps should be taken upon the diagnosis

    Polymerase Chain Reaction and Its Application in the Diagnosis of Infectious Keratitis

    Get PDF
    PCR involves a repeating cycle of replication to amplify small segments of deoxyribonucleic acid (DNA). A novel application of this technique is microbial identification in infectious keratitis, one of the leading causes of blindness in the world. PCR is more sensitive than biological stains and culture, which are considered the current gold standards for diagnosing infectious keratitis. The diagnosis and treatment of infectious keratitis cost the United States millions of dollars in health expenditure. PCR may help offset that cost by allowing for individualized disease management and screening for multiple antibiotic-resistant genes. While beneficial, PCR demonstrates lower specificity rates compared to culture and stain, indicating its shortcomings; this can be overcome by performing PCR after narrowing the pool of potential microorganisms. This article examines the clinical utility of PCR in cases of infectious keratitis by evaluating its reliability, validity, associated costs, and indications

    Comparative Analysis of LASIK Flap Diameter and its Centration Using Two Different Femtosecond Lasers

    Get PDF
    The aim of this study was to compare the diameter, accuracy, variability, and centration with respect to the limbus of corneal flaps created by two femtosecond lasers, the VisuMax, and Wavelight FS200, for laser in situ keratomileusis (LASIK) and how these flaps affect visual outcomes. This is a retrospective chart review of flap morphology created during LASIK Surgery. Overall, 168 eyes underwent flap creation using the WaveLight FS200 laser, and on 189 eyes, the VisuMax laser was used. Of these total number, flap morphology was analyzed in a random sample of 158 eyes; 80 with the Visumax laser and 78 with the WaveLight FS200 laser. Intraoperative photos of the flaps taken by the Wavelight Allegretto EX500 were analyzed. Flap diameters and centration were measured using Adobe Acrobat Pro. All patients had visual acuity measurements including uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), spherical equivalent refraction (SE) and refractive astigmatism recorded three months postoperatively. Greater than 90% of patients in both groups achieved a UDVA of 20/20 postoperatively. The mean difference between targeted and achieved flap diameter was 0.50 +/- 0.15 mm in the VisuMax group and 0.35 +/- 0.15 millimeters (mm) in the FS200 group (P<0.01). The flap diameters of the VisuMax group were more precise with a variance of 0.024 mm compared to a variance of 0.038 mm in the FS200 group (P<0.05). VisuMax flaps were more nasally displaced (log(NA/TA) = -0.21 +/- 0.10 mm) compared to the FS200 flaps (log(NA/TA) = 0.03 +/- 0.10 mm), (P< 0.01). We concluded that both the VisuMax and FS200 created flaps larger than the preoperative targeted diameter. VisuMax created corneal flaps that had a greater degree of deviation from the targeted diameter when compared to flaps from the FS200. However, there was less variance in the VisuMax flap diameter. In addition, VisuMax flaps were more nasally displaced. There were no statistically significant differences in visual outcomes when comparing the two femtosecond lasers

    Advances in Biomechanical Parameters for Screening of Refractive Surgery Candidates: A Review of the Literature, Part III

    Get PDF
    Corneal biomechanical properties have garnered significant interest in their relation to the development of ectatic corneal disease. Alongside the advent of corneal tomography and Scheimpflug imaging such as Pentacam and Galilei, there have been advances in assessing the cornea based on its biomechanical characteristics. Though the aforementioned imaging systems are highly capable of identifying morphologic abnormalities, they cannot assess mechanical stability of the cornea. This article, in contrast to Parts I and II of this article series, will focus on in vivo corneal biomechanical imaging systems. The two most readily available commercial systems include the Corvis ST and the Ocular Response Analyzer. Both of these systems aimed to characterize corneal biomechanics via distinct measurements. While in Parts I and II of this article series the authors focused on elevation, pachymetric, and keratometric data, the purpose of this article was to summarize biomechanical parameters and their clinical use in screening refractive surgery candidates. Moreover, this article explores biomechanical decompensation and its role in the development of corneal ectasia and keratoconus. There is a focus on the diagnostic accuracy of biomechanical indices in the identification of diseases such as keratoconus that may preclude a patient from undergoing refractive surgery

    Eyelid Cosmetic Enhancements and Their Associated Ocular Adverse Effects

    Get PDF
    Numerous cosmetic enhancements and augmentations to the natural appearance of the periorbital area are readily available today. Due to the increasing popularity of these cosmetic procedures, it is important for ophthalmologists to be aware of their potential risks, complications and adverse effects. The aim of this literature review was to introduce some of the most common ocular cosmetic enhancements and provide a comprehensive overview of their associated adverse effects reported in various medical journals. PubMed, Embase, and Google Scholar were used to identify articles related to the following ocular cosmetic procedures; eyelash extensions, permanent eyelid tattooing, and eyelash dyeing. The most common complication associated with eyelash extensions was allergic blepharitis (79%). Allergic granulomatous reactions were the predominant complication in patients who underwent eyelid tattooing (56%). Besides, 60% of subjects who underwent eyelash dyeing experienced allergic contact dermatitis as the most common adverse effect. Although millions of these procedures are performed annually without any adverse effects, reports of complications continue to increase in the literature. Knowledge of the possible adverse effects associated with these enhancements is important for eye care providers and licensed estheticians to be aware of given both the direct and indirect effects they may have on ocular health and visual outcomes

    Galilei Corneal Tomography for Screening of Refractive Surgery Candidates: A Review of the Literature, Part II

    Get PDF
    Corneal topography is the most widely used technology for examining the anterior corneal surface. Scheimpflug imaging is a newer technique that allows for measurement of both the anterior and posterior corneal surface, which allows for three-dimensional reconstruction of the cornea. This is of particular interest and value in the field of cataract and refractive surgery. The Galilei camera is a commercially available dual Scheimpflug system that combines curvature data from Placido disc-based corneal topography with elevation data from Scheimpflug technology. The addition of Placido disc topography makes the Galilei unique from its more popular counterpart, the Pentacam, which was discussed in Part I. Compared to the Pentacam, and however, the Galilei analyzer is a newer system that has emerged as a valuable screening tool given its dual Scheimpflug capability. In the first article of this series, the authors summarized the refractive indices available on the Pentacam system with the purpose of identifying the best diagnostic parameters for keratoconus. Similarly, the purpose of this article is to summarize corneal surface indices available on the Galilei system and evaluate their use in screening of the refractive surgery candidate. Since post-operative keratectasia is still prevalent, this paper aims to identify the most clinically relevant indices that may be used in pre-operative evaluation

    Eyelid Cosmetic Enhancements and Their Associated Ocular Adverse Effects

    Get PDF
    Numerous cosmetic enhancements and augmentations to the natural appearance of the periorbital area are readily available today. Due to the increasing popularity of these cosmetic procedures, it is important for ophthalmologists to be aware of their potential risks, complications and adverse effects. The aim of this literature review was to introduce some of the most common ocular cosmetic enhancements and provide a comprehensive overview of their associated adverse effects reported in various medical journals. PubMed, Embase, and Google Scholar were used to identify articles related to the following ocular cosmetic procedures; eyelash extensions, permanent eyelid tattooing, and eyelash dyeing. The most common complication associated with eyelash extensions was allergic blepharitis (79%). Allergic granulomatous reactions were the predominant complication in patients who underwent eyelid tattooing (56%). Besides, 60% of subjects who underwent eyelash dyeing experienced allergic contact dermatitis as the most common adverse effect. Although millions of these procedures are performed annually without any adverse effects, reports of complications continue to increase in the literature. Knowledge of the possible adverse effects associated with these enhancements is important for eye care providers and licensed estheticians to be aware of given both the direct and indirect effects they may have on ocular health and visual outcomes

    Biological Staining and Culturing in Infectious Keratitis: Controversy in Clinical Utility

    Get PDF
    Infectious keratitis causes significant, financial burden and is only increasing in frequency with contact lens use. Despite this, no retrospective studies, prospective studies, or clinical trials have evaluated the diagnostic validity of clinical guidelines in cases of infectious keratitis. Currently, standard of care recommends that corneal samples be obtained for staining and culturing in select patients showing evidence of corneal ulceration. Ideally, diagnostic information from corneal sampling is thought to help guide therapeutic interventions, prevent disease progression, reduce antibiotic resistance, and decrease overall expenditures for the management and treatment of infectious keratitis. However, current staining and culturing methods are limited by poor sensitivity in non-bacterial cases (i.e. fungal, viral) and lengthy turnaround times, and these methods do not frequently change clinical decision making. Newer fluoroquinolones and broad-spectrum antibiotics resolve the vast majority of cases of infectious keratitis, rendering cultures less essential for management. We studied the clinical utility of obtaining corneal samples for culturing and staining and the need for future research to establish superior diagnostic guidelines for their use in infectious keratitis

    A Modified Small-Incision Lenticule Intrastromal Keratoplasty (sLIKE) for the Correction of High Hyperopia: A Description of a New Surgical Technique and Comparison to Lenticule Intrastromal Keratoplasty (LIKE)

    Get PDF
    Patients with high hyperopia are generally confined to either spectacle wear or contact lenses as a primary means of refractive correction. For this patient population, the surgical corrective methods, such as hyperopic laser assisted in-situ keratomileusis (LASIK) and photorefractive keratectomy (PRK) are imperfect options due to induction of higher-order aberrations, optical regression, and loss of best corrected distance visual acuity. Recently, there has been growing interest in lenticule implantation underneath a flap via lenticule intrastromal keratoplasty (LIKE) for high hyperopia correction (+3 diopters to +10 diopters). We instead propose a modified surgical technique (small-incision lenticule intrastromal keratoplasty, sLIKE), in which the lenticule is implanted inside an intrastromal pocket thereby causing less injury to the subbasal nerve plexus injury, less postoperative dry eye symptoms, less reduction in biomechanical strength, and lower chances for epithelial ingrowth. We provide an overview of these novel surgical techniques to treat high hyperopia, and compare the associated advantages and disadvantages. In addition, we will discuss the enhancement options and methods of optimization for both surgical techniques.Â
    corecore