182 research outputs found

    Power-law correlations and orientational glass in random-field Heisenberg models

    Full text link
    Monte Carlo simulations have been used to study a discretized Heisenberg ferromagnet (FM) in a random field on simple cubic lattices. The spin variable on each site is chosen from the twelve [110] directions. The random field has infinite strength and a random direction on a fraction x of the sites of the lattice, and is zero on the remaining sites. For x = 0 there are two phase transitions. At low temperatures there is a [110] FM phase, and at intermediate temperature there is a [111] FM phase. For x > 0 there is an intermediate phase between the paramagnet and the ferromagnet, which is characterized by a |k|^(-3) decay of two-spin correlations, but no true FM order. The [111] FM phase becomes unstable at a small value of x. At x = 1/8 the [110] FM phase has disappeared, but the power-law correlated phase survives.Comment: 8 pages, 12 Postscript figure

    Sandpiles with height restrictions

    Full text link
    We study stochastic sandpile models with a height restriction in one and two dimensions. A site can topple if it has a height of two, as in Manna's model, but, in contrast to previously studied sandpiles, here the height (or number of particles per site), cannot exceed two. This yields a considerable simplification over the unrestricted case, in which the number of states per site is unbounded. Two toppling rules are considered: in one, the particles are redistributed independently, while the other involves some cooperativity. We study the fixed-energy system (no input or loss of particles) using cluster approximations and extensive simulations, and find that it exhibits a continuous phase transition to an absorbing state at a critical value zeta_c of the particle density. The critical exponents agree with those of the unrestricted Manna sandpile.Comment: 10 pages, 14 figure

    Sex Differences in Mortality After Transcatheter Aortic Valve Replacement for Severe Aortic Stenosis

    Get PDF
    ObjectivesThe aim of this study was to examine sex differences in outcome after transcatheter aortic valve replacement (TAVR) with real-world data from 2 large centers in Canada.BackgroundTranscatheter aortic valve replacement is an effective alternative to surgical valve replacement in symptomatic patients with severe aortic stenosis, but the impact of sex on outcomes remains unclear. The PARTNER (Placement of Aortic Transcatheter Valves) 1A trial demonstrated greater benefit of TAVR over surgery in women, but whether this was due to the poorer surgical outcome of women or better TAVR outcome, compared with men, is unknown.MethodsConsecutive patients (n = 641) undergoing TAVR in Vancouver and Quebec City, Canada, were evaluated. Differences in all-cause mortality were examined with Kaplan-Meier estimates, adjusted logistic regression, and proportional hazards models.ResultsWomen comprised 51.3% of the cohort. Balloon-expandable valves were used in 97% of cases, with transapical approach in 51.7 % women and 38.1% men. Women had more major vascular complications (12.4% vs. 5.4%, p = 0.003) and borderline significantly more major/life-threatening bleeds (21.6% vs. 15.8%, p = 0.08). At baseline, women had higher aortic gradients and worse renal function but better ejection fractions. Men had more comorbidities: prior myocardial infarction, prior revascularization, and chronic obstructive pulmonary disease. The adjusted odds ratio for 30-day all-cause mortality favored women, 0.39 (95% confidence interval: 0.19 to 0.80; p = 0.01), and this benefit persisted for 2 years, hazard ratio 0.60 (95% confidence interval: 0.41 to 0.88; p = 0.008).ConclusionsFemale sex is associated with better short- and long-term survival after TAVR. Added to the PARTNER 1A findings, these results suggest TAVR might be the preferred treatment option for elderly women with symptomatic severe aortic stenosis

    Pair contact process with a particle source

    Full text link
    We study the phase diagram and critical behavior of the one-dimensional pair contact process (PCP) with a particle source using cluster approximations and extensive simulations. The source creates isolated particles only, not pairs, and so couples not to the order parameter (the pair density) but to a non-ordering field, whose state influences the evolution of the order parameter. While the critical point p_c shows a singular dependence on the source intensity, the critical exponents appear to be unaffected by the presence of the source, except possibly for a small change in beta. In the course of our study we obtain high-precision values for the critical exponents of the standard PCP, confirming directed-percolation-like scaling.Comment: 15 pages, 9 figure

    Impact of postdilatation on performance of bioresorbable vascular scaffolds in patients with acute coronary syndrome compared with everolimus-eluting stents: A propensity score-matched analysis from a multicenter “real-world” registry

    Get PDF
    Background: Safety and efficacy of bioresorbable vascular scaffolds (BRS) and the role of postdilatation on outcome in acute coronary syndrome (ACS) patients compared with those of everolimus-eluting stents (EES) remain unknown. The aim of the study is to compare the safety and efficacy of BRS with EES in ACS and to investigate the role of BRS postdilatation. Methods: Consecutive ACS patients undergoing BRS implantation in 8 centers were com­pared with those with EES before and after propensity score matching. Major adverse cardiac event (MACE), myocardial infarction, and target lesion revascularization (TLR) were the primary endpoint. Sensitivity analysis was performed according to postdilatation after BRS implantation. We enrolled 303 BRS and 748 EES patients; 215 from each group were com­pared after matching, and 117 (55.2%) BRS patients were treated with postdilatation. Results: After a median follow-up of 24.0 months, MACE rates were higher in BRS patients than in EES patients (9.3% vs. 4.7%, p < 0.001), mainly driven by TLR (6.1% vs. 1.9%, p < 0.001). Stent thrombosis increased in the BRS group (2.8% vs. 0.9%, p = 0.01). How­ever, after sensitivity analysis, MACE rates in BRS patients with postdilatation were signifi­cantly lower than in those without, comparable to EES patients (6.0% vs. 12.6% vs. 4.7%, p < 0.001). The same trend was observed for TLR (3.4% vs. 8.4% vs. 1.9%, p < 0.001). Stent thrombosis rates were higher in both the BRS groups than in EES patients (2.6% vs. 3.2% vs. 0.9%, p = 0.045). Conclusions: Postdilatation appears effective when using BRS in ACS patients. MACE rates are comparable to those of EES, although scaffold thrombosis is not negligible. Randomized prospective studies are required for further investigation
    • …
    corecore