7 research outputs found

    Multibody system of the lower extremity for testing THR.

    No full text
    <p>(a) Multibody topology with illustration of the joint coordinates and the fictive planar joint in the sagittal plane indicated as one revolute (R) and two prismatic (P) joints. (b) Measured and transferred coordinates <math><msub><mi>c</mi><mo>¯</mo><mn>1</mn></msub></math>, <math><msub><mi>c</mi><mo>¯</mo><mn>2</mn></msub></math>, <math><msub><mi>c</mi><mo>¯</mo><mn>3</mn></msub></math> in constrained directions of the THR. (c) Musculoskeletal model with implanted CAD geometries of the THR.</p

    Physical setup of the HiL test system for testing THR.

    No full text
    <p>The THR components are fixed on mounting devices attached to the endeffector and the compliant support, respectively. Measurements are taken via the force-torque sensor and displacement sensors.</p

    Impact of muscle element removal emulating a posterior surgical approach on HiL-simulated THR load situation with focus on the sitting down phase of the deep maneuver.

    No full text
    <p>The HiL simulations are based on parameter sets â‘¡, â‘¢ from <a href="http://www.plosone.org/article/info:doi/10.1371/journal.pone.0145798#pone.0145798.t001" target="_blank">Table 1</a>. <b>a</b> Comparison between the intact (blue lines) and the resected (red lines) case for hip joint rotations <i>q</i><sub>3</sub>, <i>q</i><sub>1</sub>, <i>q</i><sub>2</sub>, measured displacement |<i><b>c</b></i>| between femoral head and acetabular cup, components of the predicted reaction force <i><b>f</b></i><sup><i>r</i></sup> given in the pelvic reference frame [<a href="http://www.plosone.org/article/info:doi/10.1371/journal.pone.0145798#pone.0145798.ref049" target="_blank">49</a>], and measured resisting torque |<i><b>Ï„</b></i><sup><i>f</i></sup>|. Impingement occurs at â—‹ and dislocation at â—‡. <b>b</b> Direction of the hip joint reaction force with respect to the frontal plane of the pelvic reference frame [<a href="http://www.plosone.org/article/info:doi/10.1371/journal.pone.0145798#pone.0145798.ref049" target="_blank">49</a>] with illustration of the head position at and after impingement for the intact (above) and the resected (below) case.</p

    Functional principle of the HiL simulation for testing THR with respect to dislocation.

    No full text
    <p>The transfer between the musculoskeletal model and the physical setup is illustrated within the two control loops on kinematic and force level, respectively. The THR components are attached to mounting devices which are fixed to the endeffector of the robot (stem) and the compliant support (cup).</p

    Impact of implant position on HiL-simulated THR load situation for a deep seating-to-rising motion cycle.

    No full text
    <p>Implant positions are defined by inclination <i>ι</i>, cup anteversion <i>β</i>, and stem antetorsion <i>ϑ</i> with parameter sets ③, ④, ⑤, ⑥ from <a href="http://www.plosone.org/article/info:doi/10.1371/journal.pone.0145798#pone.0145798.t001" target="_blank">Table 1</a>. Impingement occurs at ○ and dislocation at ◇. <b>a</b> Flexion angle <i>q</i><sub>3</sub>. <b>b</b> Measured displacement |<i><b>c</b></i>| between femoral head and acetabular cup. <b>c</b> Predicted reaction force |<i><b>f</b></i><sup><i>r</i></sup>|. <b>d</b> Measured resisting torque |<i><b>τ</b></i><sup><i>f</i></sup>|.</p

    Impact of load level adjusted by body mass on HiL-simulated THR load situation for deep seating-to-rising.

    No full text
    <p>The HiL simulations are based on parameter sets â‘¡, â‘¢, â‘£ from <a href="http://www.plosone.org/article/info:doi/10.1371/journal.pone.0145798#pone.0145798.t001" target="_blank">Table 1</a>. Impingement occurs at â—‹ and dislocation at â—‡. <b>a</b> Predicted reaction force |<i><b>f</b></i><sup><i>r</i></sup>| over flexion angle. <b>b</b> Measured resisting torque |<i><b>Ï„</b></i><sup><i>f</i></sup>| over flexion angle.</p