43 research outputs found

    Confirmation of Sentinel Lymph Node Identity by Analysis of Fine-Needle Biopsy Samples Using Inductively Coupled Plasma–Mass Spectrometry

    Get PDF
    Background: The sentinel lymph node (SLN) biopsy technique is a reliable means of determining the tumor-harboring status of regional lymph nodes in melanoma patients. When technetium 99 m-labeled antimony trisulfide colloid (99 mTc-Sb2S3) particles are used to perform preoperative lymphoscintigraphy for SLN identification, they are retained in the SLN but are absent or present in only tiny amounts in non-SLNs. The present study investigated the potential for a novel means of assessing the accuracy of surgical identification of SLNs. This involved the use of inductively coupled plasma-mass spectrometry (ICP-MS) to analyze antimony concentrations in fine-needle biopsy (FNB) samples from surgically procured lymph nodes. Methods: A total of 47 FNB samples from surgically excised lymph nodes (32 SLNs and 15 non-SLNs) were collected. The SLNs were localized by preoperative lymphoscintigraphy that used 99 mTc-Sb2S3, blue dye, and gamma probe techniques. The concentrations of antimony were measured in the FNB samples by ICP-MS. Results: The mean and median antimony concentrations (in parts per billion) were .898 and .451 in the SLNs, and .015 and .068 in the non-SLNs, the differences being highly statistically significant (P < .00005). Conclusions: Our results show that ICP-MS analysis of antimony concentrations in FNB specimens from lymph nodes can accurately confirm the identity of SLNs. Used in conjunction with techniques such as proton magnetic resonance spectroscopy for the nonsurgical evaluation of SLNs, ICP-MS analysis of antimony concentrations in FNB samples could potentially serve as a minimally invasive alternative to surgery and histopathologic evaluation to objectively classify a given node as sentinel or nonsentinel and determine its tumor-harboring status. © 2007 The Author(s)

    Diagnostic Accuracy of Fine Needle Biopsy for Metastatic Melanoma and Its Implications for Patient Management

    Get PDF
    The use of fine needle biopsy (FNB) for the diagnosis of metastatic melanoma can lead to the early removal and treatment of metastases, reduce the frequency of unnecessary surgery, and facilitate the staging of patients enrolled in clinical trials of adjuvant therapies. In this study, the accuracy of FNB for the diagnosis of metastatic melanoma was investigated. A retrospective cohort study was performed with 2204 consecutive FNBs performed on 1416 patients known or suspected to have metastatic melanoma. Almost three-quarters (1582) of these FNBs were verified by either histopathologic diagnosis following surgical resection or clinical follow-up. FNB for metastatic melanoma was found to have an overall sensitivity of 92.1% and a specificity of 99.2%, with 69 false-negative and 5 false-positive findings identified. The sensitivity of the procedure was found to be influenced by six factors. The use of immunostains, reporting of the specimen by a cytopathologist who had reported >500 cases, lesions located in the skin and subcutis, and patients with ulcerated primary melanomas were factors associated with a significant improvement in the sensitivity of the test. However, FNBs performed in masses located in lymph nodes of the axilla and FNBs that required more than one needle pass to obtain a sample were far more likely to result in false-negative results. FNB is a rapid, accurate, and clinically useful technique for the assessment of disease status in patients with suspected metastatic melanoma

    Letter to the Editor

    No full text

    Variation in cutaneous lymphatic flow rates

    No full text
    corecore