12 research outputs found
Impact of Regional Systems of Care on Disparities in Care Among Female and Black Patients Presenting With ST‐Segment–Elevation Myocardial Infarction
BACKGROUND: The American Heart Association Mission: Lifeline STEMI (ST-segment-elevation myocardial infarction) Systems Accelerator program, conducted in 16 regions across the United States to improve key care processes, resulted in more patients being treated within national guideline goals (time from first medical contact to device: <90 minutes for direct presenters to hospitals capable of performing percutaneous coronary intervention; <120 minutes for transfers). We examined whether the effort reduced reperfusion disparities in the proportions of female versus male and black versus white patients.
METHODS AND RESULTS: In total, 23 809 patients (29.3% female, 82.3% white, and 10.7% black) presented with acute STEMI between July 2012 and March 2014. Change in the proportion of patients treated within guideline goals was compared between sex and race subgroups for patients presenting directly to hospitals capable of performing percutaneous coronary intervention (n=18 267) and patients requiring transfer (n=5542). The intervention was associated with an increase in the proportion of men treated within guideline goals that presented directly (58.7-62.1%, P=0.01) or were transferred (43.3-50.7%, P<0.01). An increase was also seen among white patients who presented directly (57.7-59.9%, P=0.02) or were transferred (43.9-48.8%, P<0.01). There was no change in the proportion of female or black patients treated within guideline goals, including both those presenting directly and transferred.
CONCLUSION: The STEMI Systems Accelerator project was associated with an increase in the proportion of patients meeting guideline reperfusion targets for male and white patients but not for female or black patients. Efforts to organize systems of STEMI care should implement additional processes targeting barriers to timely reperfusion among female and black patients
Regional Systems of Care Demonstration Project: American Heart Association Mission: Lifeline STEMI Systems Accelerator.
BACKGROUND: Up to 50% of patients fail to meet ST-segment-elevation myocardial infarction (STEMI) guideline goals recommending a first medical contact-to-device time of <90 minutes for patients directly presenting to percutaneous coronary intervention-capable hospitals and <120 minutes for transferred patients. We sought to increase the proportion of patients treated within guideline goals by organizing coordinated regional reperfusion plans.
METHODS: We established leadership teams, coordinated protocols, and provided regular feedback for 484 hospitals and 1253 emergency medical services (EMS) agencies in 16 regions across the United States.
RESULTS: Between July 2012 and December 2013, 23 809 patients presented with acute STEMI (direct to percutaneous coronary intervention hospital: 11 765 EMS transported and 6502 self-transported; 5542 transferred). EMS-transported patients differed from self-transported patients in symptom onset to first medical contact time (median, 47 versus 114 minutes), incidence of cardiac arrest (10% versus 3%), shock on admission (11% versus 3%), and in-hospital mortality (8% versus 3%; P<0.001 for all comparisons). There was a significant increase in the proportion of patients meeting guideline goals of first medical contact-to-device time, including those directly presenting via EMS (50% to 55%; P<0.001) and transferred patients (44%-48%; P=0.002). Despite regional variability, the greatest gains occurred among patients in the 5 most improved regions, increasing from 45% to 57% (direct EMS; P<0.001) and 38% to 50% (transfers; P<0.001).
CONCLUSIONS: This Mission: Lifeline STEMI Systems Accelerator demonstration project represents the largest national effort to organize regional STEMI care. By focusing on first medical contact-to-device time, coordinated treatment protocols, and regional data collection and reporting, we were able to increase significantly the proportion of patients treated within guideline goals
Association of Rapid Care Process Implementation on Reperfusion Times Across Multiple ST-Segment–Elevation Myocardial Infarction Networks
BACKGROUND: The Mission: Lifeline STEMI Systems Accelerator program, implemented in 16 US metropolitan regions, resulted in more patients receiving timely reperfusion. We assessed whether implementing key care processes was associated with system performance improvement.
METHODS AND RESULTS: Hospitals (n=167 with 23 498 ST-segment-elevation myocardial infarction patients) were surveyed before (March 2012) and after (July 2014) program intervention. Data were merged with patient-level clinical data over the same period. For reperfusion, hospitals were grouped by whether a specific process of care was implemented, preexisting, or never implemented. Uptake of 4 key care processes increased after intervention: prehospital catheterization laboratory activation (62%-91%; P<0.001), single call transfer protocol from an outside facility (45%-70%; P<0.001), and emergency department bypass for emergency medical services direct presenters (48%-59%; P=0.002) and transfers (56%-79%; P=0.001). There were significant differences in median first medical contact-to-device times among groups implementing prehospital activation (88 minutes implementers versus 89 minutes preexisting versus 98 minutes nonimplementers; P<0.001 for comparisons). Similarly, patients treated at hospitals implementing single call transfer protocols had shorter median first medical contact-to-device times (112 versus 128 versus 152 minutes; P<0.001). Emergency department bypass was also associated with shorter median first medical contact-to-device times for emergency medical services direct presenters (84 versus 88 versus 94 minutes; P<0.001) and transfers (123 versus 127 versus 167 minutes; P<0.001).
CONCLUSIONS: The Accelerator program increased uptake of key care processes, which were associated with improved system performance. These findings support efforts to implement regional ST-segment-elevation myocardial infarction networks focused on prehospital catheterization laboratory activation, single call transfer protocols, and emergency department bypass
Optische Emissionstomographie an chemisch aktiven Niederdruckplasmen
SIGLEAvailable from TIB Hannover: F95B2433+a / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekBundesministerium fuer Bildung, Wissenschaft, Forschung und Technologie, Bonn (Germany)DEGerman
Zeitaufgeloeste optische Emissionstomographie zur Diagnostik technisch relevanter, chemisch aktiver Niederdruckplasmen Abschlussbericht
SIGLEAvailable from TIB Hannover: F98B935+a / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekBundesministerium fuer Bildung, Wissenschaft, Forschung und Technologie, Bonn (Germany)DEGerman
Impact of Regionalization of ST-Segment-Elevation Myocardial Infarction Care on Treatment Times and Outcomes for Emergency Medical Services-Transported Patients Presenting to Hospitals With Percutaneous Coronary Intervention: Mission: Lifeline Accelerator-2.
BACKGROUND: Regional variations in reperfusion times and mortality in patients with ST-segment-elevation myocardial infarction are influenced by differences in coordinating care between emergency medical services (EMS) and hospitals. Building on the Accelerator-1 Project, we hypothesized that time to reperfusion could be further reduced with enhanced regional efforts.
METHODS: Between April 2015 and March 2017, we worked with 12 metropolitan regions across the United States with 132 percutaneous coronary intervention-capable hospitals and 946 EMS agencies. Data were collected in the ACTION (Acute Coronary Treatment and Intervention Outcomes Network)-Get With The Guidelines Registry for quarterly Mission: Lifeline reports. The primary end point was the change in the proportion of EMS-transported patients with first medical contact to device time ≤90 minutes from baseline to final quarter. We also compared treatment times and mortality with patients treated in hospitals not participating in the project during the corresponding time period.
RESULTS: During the study period, 10 730 patients were transported to percutaneous coronary intervention-capable hospitals, including 974 in the baseline quarter and 972 in the final quarter who met inclusion criteria. Median age was 61 years; 27% were women, 6% had cardiac arrest, and 6% had shock on admission; 10% were black, 12% were Latino, and 10% were uninsured. By the end of the intervention, all process measures reflecting coordination between EMS and hospitals had improved, including the proportion of patients with a first medical contact to device time of ≤90 minutes (67%-74%;
CONCLUSIONS: Organization of care among EMS and hospitals in 12 regions was associated with significant reductions in time to reperfusion in patients with ST-segment-elevation myocardial infarction as well as in in-hospital mortality. These findings support a more intensive regional approach to emergency care for patients with ST-segment-elevation myocardial infarction
On the capability of spectrally resolved optical emission tomography for the diagnostic of non-isothermal low pressure technological plasmas
A laboratory scale, inexpensive single channel optical emission computerized tomography setup was tested for its usefulness to answer technological questions. A special graphite substrate was inserted in the short positive column of a structured hydrogen DC-plasma and considerations how to identify the influence of different kinds of noise and systematic errors on the obtainable tomographic information already during measurements were performed. This paper demonstrates, that valuable information about non regular plasma structures near arbitrarily shaped substrates in optical thin plasmas can be obtained without any pretreatment of the measured data. Test and preview procedures based on the sinogram, the conservation law of total emissivity, the consistency-theorem and the FOURIER-slice-theorem are shown to be useful for getting additional details. Special pre-treatments of the measured data like cubic spline smoothing, center-of-mass-transformation, substration of background or correction of intensity and the kind of regularization can be applied to the measured data and further numerical evaluations like line cuts and 3D-intensity distribution calculations are possible. (orig.)SIGLEAvailable from TIB Hannover: DtF QN1(62,19) / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekBundesministerium fuer Bildung, Wissenschaft, Forschung und Technologie, Bonn (Germany)DEGerman