1,530 research outputs found
FACSGen 2.0 animation software: Generating 3D FACS-valid facial expressions for emotion research
In this article, we present FACSGen 2.0, new animation software for creating static and dynamic three-dimensional facial expressions on the basis of the Facial Action Coding System (FACS). FACSGen permits total control over the action units (AUs), which can be animated at all levels of intensity and applied alone or in combination to an infinite number of faces. In two studies, we tested the validity of the software for the AU appearance defined in the FACS manual and the conveyed emotionality of FACSGen expressions. In Experiment 1, four FACS-certified coders evaluated the complete set of 35 single AUs and 54 AU combinations for AU presence or absence, appearance quality, intensity, and asymmetry. In Experiment 2, lay participants performed a recognition task on emotional expressions created with FACSGen software and rated the similarity of expressions displayed by human and FACSGen faces. Results showed good to excellent classification levels for all AUs by the four FACS coders, suggesting that the AUs are valid exemplars of FACS specifications. Lay participants' recognition rates for nine emotions were high, and comparisons of human and FACSGen expressions were very similar. The findings demonstrate the effectiveness of the software in producing reliable and emotionally valid expressions, and suggest its application in numerous scientific areas, including perception, emotion, and clinical and neuroscience research
Recommended from our members
Gene expression changes within Müller glial cells in retinitis pigmentosa
Purpose: Retinitis pigmentosa (RP) is a progressive retinal degeneration in which the retina loses nearly all of its photoreceptor cells and undergoes major structural changes. Little is known regarding the role the resident glia, the Müller glia, play in the progression of the disease. In this article, we define gene expression changes in Müller glial cells (MGCs) from two different mouse models of RP, the retinal degeneration 1 (rd1) and rhodopsin knockout (Rhod-ko) models. The RNA repertoire of single MGCs was comprehensively profiled, and a comparison was made between MGCs from wild-type (WT) and mutant retinas. Two time points were chosen for analysis, one at the peak of rod photoreceptor death and one during the period of cone photoreceptor death. Methods: Retinas were dissociated, and single MGCs were chosen under a dissecting microscope using a micropipette. Single cell cDNAs were generated and genome-wide profiles were obtained by hybridization to Affymetrix arrays. A comparison was made among all samples to discover the changes in gene expression during the periods of rod and cone photoreceptor death. Results: MGCs respond to retinal degeneration by undergoing gliosis, a process marked by the upregulation of glial fibrillary acidic protein (Gfap). Many additional transcripts were found to change. These can be placed into functional clusters, such as retinal remodeling, stress response, and immune-related response. Conclusions: A high degree of heterogeneity among the individual cells was observed, possibly due to their different spatial proximities to dying cells and/or inherent heterogeneity among MGCs
Recommended from our members
Sensing and seeing associated with overlapping occipitoparietal activation in simultaneous EEG-fMRI.
The presence of a change in a visual scene can influence brain activity and behavior, even in the absence of full conscious report. It may be possible for us to sense that such a change has occurred, even if we cannot specify exactly where or what it was. Despite existing evidence from electroencephalogram (EEG) and eye-tracking data, it is still unclear how this partial level of awareness relates to functional magnetic resonance imaging (fMRI) blood oxygen level dependent (BOLD) activation. Using EEG, fMRI, and a change blindness paradigm, we found multi-modal evidence to suggest that sensing a change is distinguishable from being blind to it. Specifically, trials during which participants could detect the presence of a colour change but not identify the location of the change (sense trials), were compared to those where participants could both detect and localise the change (localise or see trials), as well as change blind trials. In EEG, late parietal positivity and N2 amplitudes were larger for localised changes only, when compared to change blindness. However, ERP-informed fMRI analysis found no voxels with activation that significantly co-varied with fluctuations in single-trial late positivity amplitudes. In fMRI, a range of visual (BA17,18), parietal (BA7,40), and mid-brain (anterior cingulate, BA24) areas showed increased fMRI BOLD activation when a change was sensed, compared to change blindness. These visual and parietal areas are commonly implicated as the storage sites of visual working memory, and we therefore argue that sensing may not be explained by a lack of stored representation of the visual display. Both seeing and sensing a change were associated with an overlapping occipitoparietal network of activation when compared to blind trials, suggesting that the quality of the visual representation, rather than the lack of one, may result in partial awareness during the change blindness paradigm
Factor structure and validity of the MacArthur Competence Assessment Tool--Criminal Adjudication.
Development of Lumped Element Kinetic Inductance Detectors for NIKA
Lumped-element kinetic inductance detectors(LEKIDs) have recently shown
considerable promise as direct absorption mm-wavelength detectors for
astronomical applications. One major research thrust within the N\'eel Iram
Kids Array (NIKA) collaboration has been to investigate the suitability of
these detectors for deployment at the 30-meter IRAM telescope located on Pico
Veleta in Spain. Compared to microwave kinetic inductance detectors (MKID),
using quarter wavelength resonators, the resonant circuit of a LEKID consists
of a discrete inductance and capacitance coupled to a feedline. A high and
constant current density distribution in the inductive part of these resonators
makes them very sensitive. Due to only one metal layer on a silicon substrate,
the fabrication is relatively easy. In order to optimize the LEKIDs for this
application, we have recently probed a wide variety of individual resonator and
array parameters through simulation and physical testing. This included
determining the optimal feed-line coupling, pixel geometry, resonator
distribution within an array (in order to minimize pixel cross-talk), and
resonator frequency spacing. Based on these results, a 144-pixel Aluminum array
was fabricated and tested in a dilution fridge with optical access, yielding an
average optical NEP of ~2E-16 W/Hz^1/2 (best pixels showed NEP = 6E-17 W/Hz^1/2
under 4-8 pW loading per pixel). In October 2010 the second prototype of LEKIDs
has been tested at the IRAM 30 m telescope. A new LEKID geometry for 2
polarizations will be presented. Also first optical measurements of a titanium
nitride array will be discussed.Comment: 5 pages, 12 figures; ISSTT 2011 Worksho
Social Science and the Courts: The Role of Amicus Curiae Briefs
Social scientists have increasingly become involved in the submission of amicus curiae or friend of the court briefs in legal cases being decided by state and federal courts. This increase has triggered considerable debate about the use of briefs to communicate relevant social science research. This article evaluates the strengths and weaknesses of various methods of summarizing social science research for the courts. It also reviews the procedures for submitting briefs developed by the American Psychology-Law Society which, in collaboration with the American Psychological Association, has submitted its first brief in Maryland v. Craig, a case recently decided by the U.S. Supreme Court
Electronics and data acquisition demonstrator for a kinetic inductance camera
A prototype of digital frequency multiplexing electronics allowing the real
time monitoring of kinetic inductance detector (KIDs) arrays for mm-wave
astronomy has been developed. It requires only 2 coaxial cables for
instrumenting a large array. For that, an excitation comb of frequencies is
generated and fed through the detector. The direct frequency synthesis and the
data acquisition relies heavily on a large FPGA using parallelized and
pipelined processing. The prototype can instrument 128 resonators (pixels) over
a bandwidth of 125 MHz. This paper describes the technical solution chosen, the
algorithm used and the results obtained
- …