8 research outputs found

    Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control

    Get PDF
    The aim of this study was to assess the diagnostic accuracy of dual-source computed tomography (DSCT) for evaluation of coronary artery disease (CAD) in a population with extensive coronary calcifications without heart rate control. Thirty patients (24 male, 6 female, mean age 63.1±11.3years) with a high pre-test probability of CAD underwent DSCT coronary angiography and invasive coronary angiography (ICA) within 14±9days. No beta-blockers were administered prior to the scan. Two readers independently assessed image quality of all coronary segments with a diameter ≥1.5mm using a four-point score (1: excellent to 4: not assessable) and qualitatively assessed significant stenoses as narrowing of the luminal diameter >50%. Causes of false-positive (FP) and false-negative (FN) ratings were assigned to calcifications or motion artifacts. ICA was considered the standard of reference. Mean body mass index was 28.3±3.9kg/m2 (range 22.4-36.3kg/m2), mean heart rate during CT was 70.3±14.2bpm (range 47-102bpm), and mean Agatston score was 821±904 (range 0-3,110). Image quality was diagnostic (scores 1-3) in 98.6% (414/420) of segments (mean image quality score 1.68±0.75); six segments in three patients were considered not assessable (1.4%). DSCT correctly identified 54 of 56 significant coronary stenoses. Severe calcifications accounted for false ratings in nine segments (eight FP/one FN) and motion artifacts in two segments (one FP/one FN). Overall sensitivity, specificity, positive and negative predictive value for evaluating CAD were 96.4, 97.5, 85.7, and 99.4%, respectively. First experience indicates that DSCT coronary angiography provides high diagnostic accuracy for assessment of CAD in a high pre-test probability population with extensive coronary calcifications and without heart rate contro

    Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control

    Get PDF
    The aim of this study was to assess the diagnostic accuracy of dual-source computed tomography (DSCT) for evaluation of coronary artery disease (CAD) in a population with extensive coronary calcifications without heart rate control. Thirty patients (24 male, 6 female, mean age 63.1±11.3 years) with a high pre-test probability of CAD underwent DSCT coronary angiography and invasive coronary angiography (ICA) within 14±9 days. No beta-blockers were administered prior to the scan. Two readers independently assessed image quality of all coronary segments with a diameter ≥1.5 mm using a four-point score (1: excellent to 4: not assessable) and qualitatively assessed significant stenoses as narrowing of the luminal diameter >50%. Causes of false-positive (FP) and false-negative (FN) ratings were assigned to calcifications or motion artifacts. ICA was considered the standard of reference. Mean body mass index was 28.3±3.9 kg/m(2) (range 22.4–36.3 kg/m(2)), mean heart rate during CT was 70.3±14.2 bpm (range 47–102 bpm), and mean Agatston score was 821±904 (range 0–3,110). Image quality was diagnostic (scores 1–3) in 98.6% (414/420) of segments (mean image quality score 1.68±0.75); six segments in three patients were considered not assessable (1.4%). DSCT correctly identified 54 of 56 significant coronary stenoses. Severe calcifications accounted for false ratings in nine segments (eight FP/one FN) and motion artifacts in two segments (one FP/one FN). Overall sensitivity, specificity, positive and negative predictive value for evaluating CAD were 96.4, 97.5, 85.7, and 99.4%, respectively. First experience indicates that DSCT coronary angiography provides high diagnostic accuracy for assessment of CAD in a high pre-test probability population with extensive coronary calcifications and without heart rate control

    VEGF165 transfection decreases postischemic NF‐κB‐dependent myocardial reperfusion injury in vivo: role of eNOS phosphorylation

    No full text
    Endothelial nitric oxide synthase (eNOS) phosphorylation increases nitric oxide formation, for example, after VEGF stimulation. We investigated whether nitric oxide formed after overexpression of VEGF or of phosphomimetic eNOS (S1177D) affects PMN-induced myocardial detriment after ischemia and reperfusion. Pigs (n=8 per group) were subjected to percutaneous liposome-based gene transfer by retroinfusion of the anterior interventricular vein 48 h before LAD occlusion (60 min) and reperfusion (24 h). Thereafter, regional myocardial function was assessed as subendocardial segment shortening (SES), and infarct size was determined. Tissue from the infarct region, the noninfarcted area at risk, and a control region was analyzed for NF-kappaB activation (EMSA), tumor necrosis factor (TNF)-alpha, and E-selectin mRNA and infiltration of polymorphonuclear neutrophils (PMN). L-NAME was applied in one group of VEGF-transfected animals. NF-kappaB activition, PMN infiltration in the infarct region, and AAR were reduced after transfection of VEGF or eNOS S1177D, but not after VEGF+L-NAME coapplication. Infarct size decreased, whereas SES improved after either VEGF or eNOS S1177D transfection, an effect inhibited by L-NAME coapplication. Retroinfusion of liposomal VEGF cDNA reduces NF-kappaB-dependent postischemic inflammation and subsequent myocardial reperfusion injury, an effect mediated at least in part by enhanced eNOS phosphorylation

    Myocardial gene transfer by selective pressure-regulated retroinfusion of coronary veins: comparison with surgical and percutaneous intramyocardial gene delivery

    Get PDF
    ObjectivesWe sought to study adenoviral gene delivery using percutaneous selective pressure-regulated retroinfusion and to compare it directly with surgical and percutaneous intramyocardial delivery (PIMD) for the first time.BackgroundIntramyocardial delivery (IMD) has been recommended to be the preferred gene delivery strategy so far. However, surgical and percutaneous intramyocardial injection lead to incomplete retention of the injected viral vectors and to limited spatial myocardial distribution. Percutaneous selective pressure-regulated retroinfusion of the coronary veins was developed recently to provide an effective and more homogenous regional myocardial gene transfer.MethodsIn 15 pigs, adenoviral vectors (Ad2-CMV beta-galactosidase [β-gal] 5 × 109pfu) were applied via surgical IMD (n = 5), PIMD (n = 5), and selective pressure-regulated retroinfusion (n = 5). Seven days after gene transfer, myocardial β-gal expression was measured by ELISA.ResultsSelective retroinfusion into the anterior cardiac vein substantially increased reporter gene expression (1,039 ± 79 pg β-gal/mg protein) in the targeted left anterior descending coronary artery territory when compared with surgical (448 ± 127, p < 0.05) and PIMD (842 ± 145, p < 0.05). Both IMD approaches showed an inhomogenous β-gal expression, particularly along the injection sites, while retroinfusion resulted in a more homogenous transmural gene expression.ConclusionsPercutaneous selective pressure-regulated retroinfusion compares favorably with surgical and percutaneous intramyocardial injection techniques by providing a more homogenous and even more efficient adenoviral gene delivery

    Myocardial bridging: depiction rate and morphology at CT coronary angiography--comparison with conventional coronary angiography

    No full text
    PURPOSE: To prospectively assess the depiction rate and morphologic features of myocardial bridging (MB) of coronary arteries with 64-section computed tomographic (CT) coronary angiography in comparison to conventional coronary angiography. MATERIALS AND METHODS: Patients were simultaneously enrolled in a prospective study comparing CT and conventional coronary angiography, for which ethics committee approval and informed consent were obtained. One hundred patients (38 women, 62 men; mean age, 63.8 years +/- 11.6 [standard deviation]) underwent 64-section CT and conventional coronary angiography. Fifty additional patients (19 women, 31 men; mean age, 59.2 years +/- 13.2) who underwent CT only were also included. CT images were analyzed for the direct signs length, depth, and degree of systolic compression, while conventional angiograms were analyzed for the indirect signs step down-step up phenomenon, milking effect, and systolic compression of the tunneled segment. Statistical analysis was performed with Pearson correlation analysis, the Wilcoxon two-sample test, and Fisher exact tests. RESULTS: MB was detected with CT in 26 (26%) of 100 patients and with conventional angiography in 12 patients (12%). Mean tunneled segment length and depth at CT (n = 150) were 24.3 mm +/- 10.0 and 2.6 mm +/- 0.8, respectively. Systolic compression in the 12 patients was 31.3% +/- 11.0 at CT and 28.2% +/- 10.5 at conventional angiography (r = 0.72, P < .001). With CT, a significant correlation was not found between systolic compression and length (r = 0.16, P = .25, n = 150) but was found with depth (r = 0.65, P < .01, n = 150) of the tunneled segment. In 14 patients in whom MB was found at CT but not at conventional angiography, length, depth, and systolic compression were significantly lower than in patients in whom both modalities depicted the anomaly (P < .001, P < .01, and P < .001, respectively). CONCLUSION: The depiction rate of MB is greater with 64-section CT coronary angiography than with conventional coronary angiography. The degree of systolic compression of MB significantly correlates with tunneled segment depth but not length
    corecore