    Evolution of a beam dynamics model for the transport lines in a proton therapy facility

    Full text link
    Despite the fact that the first-order beam dynamics models allow an approximated evaluation of the beam properties, their contribution is essential during the conceptual design of an accelerator or beamline. However, during the commissioning some of their limitations appear in the comparison against measurements. The extension of the linear model to higher order effects is, therefore, demanded. In this paper, the effects of particle-matter interaction have been included in the model of the transport lines in the proton therapy facility at the Paul Scherrer Institut (PSI) in Switzerland. To improve the performance of the facility, a more precise model was required and has been developed with the multi-particle open source beam dynamics code called OPAL (Object oriented Particle Accelerator Library). In OPAL, the Monte Carlo simulations of Coulomb scattering and energy loss are performed seamless with the particle tracking. Beside the linear optics, the influence of the passive elements (e.g. degrader, collimators, scattering foils and air gaps) on the beam emittance and energy spread can be analysed in the new model. This allows for a significantly improved precision in the prediction of beam transmission and beam properties. The accuracy of the OPAL model has been confirmed by numerous measurements.Comment: 17 pages, 19 figure

    Full Scale Proton Beam Impact Testing of new CERN Collimators and Validation of a Numerical Approach for Future Operation

    Full text link
    New collimators are being produced at CERN in the framework of a large particle accelerator upgrade project to protect beam lines against stray particles. Their movable jaws hold low density absorbers with tight geometric requirements, while being able to withstand direct proton beam impacts. Such events induce considerable thermo-mechanical loads, leading to complex structural responses, which make the numerical analysis challenging. Hence, an experiment has been developed to validate the jaw design under representative conditions and to acquire online results to enhance the numerical models. Two jaws have been impacted by high-intensity proton beams in a dedicated facility at CERN and have recreated the worst possible scenario in future operation. The analysis of online results coupled to post-irradiation examinations have demonstrated that the jaw response remains in the elastic domain. However, they have also highlighted how sensitive the jaw geometry is to its mounting support inside the collimator. Proton beam impacts, as well as handling activities, may alter the jaw flatness tolerance value by ±\pm 70 μ{\mu}m, whereas the flatness tolerance requirement is 200 μ{\mu}m. In spite of having validated the jaw design for this application, the study points out numerical limitations caused by the difficulties in describing complex geometries and boundary conditions with such unprecedented requirements.Comment: 22 pages, 17 figures, Prepared for submission to JINS

    Uncertainty quantification analysis and optimization for proton therapy beam lines

    No full text
    Since many years proton therapy is an effective treatment solution against deep-seated tumors. A precise quantification of sources of uncertainty in each proton therapy aspect (e.g. accelerator, beam lines, patient positioning, treatment planning) is of profound importance to increase the accuracy of the dose delivered to the patient. Together with Monte Carlo techniques, a new research field called Uncertainty Quantification (UQ) has been recently introduced to verify the robustness of the treatment planning. In this work we present the first application of UQ as a method to identify typical errors in the transport lines of a cyclotron-based proton therapy facility and analyze their impact on the properties of the therapeutic beams. We also demonstrate the potential of UQ methods in developing optimized beam optics solutions for high-dimensional problems. Sensitivity analysis and surrogate models offer a fast way to exclude unimportant parameters frcomplex optimization problems such as the design of a superconducting gantry performed at Paul Scherrer Institute in Switzerland

    Cyclinac Medical Accelerators Using Pulsed C 6+ /H 2 + Ion Sources

    No full text
    ABSTRACT: Charged particle therapy, or so-called hadrontherapy, is developing very rapidly. There is large pressure on the scientific community to deliver dedicated accelerators, providing the best possible treatment modalities at the lowest cost. In this context, the Italian research Foundation TERA is developing fast-cycling accelerators, dubbed 'cyclinacs'. These are a combination of a cyclotron (accelerating ions to a fixed initial energy) followed by a high gradient linac boosting the ions energy up to the maximum needed for medical therapy. The linac is powered by many independently controlled klystrons to vary the beam energy from one pulse to the next. This accelerator is best suited to treat moving organs with a 4D multi-painting spot scanning technique. A dual proton/carbon ion cyclinac is here presented. It consists of an Electron Beam Ion Source, a superconducting isochronous cyclotron and a high-gradient linac. All these machines are pulsed at high repetition rate (100-400 Hz). The source should deliver both C 6+ and H 2 + ions in short pulses (1.5 ÎĽs flat-top) and with sufficient intensity (at least 10 8 fully stripped carbon ions at 300 Hz). The cyclotron accelerates the ions to 120 MeV/u. It features a compact design (with superconducting coils) and a low power consumption. The linac has a novel C-band high gradient structure and accelerates the ions to variable energies up to 400 MeV/u. High RF frequencies lead to power consumptions which are much lower than the ones of synchrotrons for the same ion extraction energy. This work is part of a collaboration with the CLIC group, which is working at CERN on highgradient electron-positron colliders

    Cyclinac medical accelerators using pulsed C6+/H2+ ion sources

    Get PDF
    20 páginas, 9 figuras, 2 tablas.-- Trabajo presentado al International Symposium on Electron Beam Ion Sources and Traps (EBIST2010), celebrado en Estocolmo (Suecia/ Abril 2010).-- This work is part of a collaboration with the CLIC group, which is working at CERN on high-gradient electron-positron colliders.-- El PDF es la versión pre-print.-- et al.Charged particle therapy, or so-called hadrontherapy, is developing very rapidly. There is large pressure on the scientific community to deliver dedicated accelerators, providing the best possible treatment modalities at the lowest cost. In this context, the Italian research Foundation TERA is developing fast-cycling accelerators, dubbed `cyclinacs'. These are a combination of a cyclotron (accelerating ions to a fixed initial energy) followed by a high gradient linac boosting the ions energy up to the maximum needed for medical therapy. The linac is powered by many independently controlled klystrons to vary the beam energy from one pulse to the next. This accelerator is best suited to treat moving organs with a 4D multipainting spot scanning technique. A dual proton/carbon ion cyclinac is here presented. It consists of an Electron Beam Ion Source, a superconducting isochronous cyclotron and a high-gradient linac. All these machines are pulsed at high repetition rate (100–400 Hz). The source should deliver both C6+ and H2+ ions in short pulses (1.5 μs flat-top) and with sufficient intensity (at least 108 fully stripped carbon ions per pulse at 300 Hz). The cyclotron accelerates the ions to 120 MeV/u. It features a compact design (with superconducting coils) and a low power consumption. The linac has a novel C-band high-gradient structure and accelerates the ions to variable energies up to 400 MeV/u. High RF frequencies lead to power consumptions which are much lower than the ones of synchrotrons for the same ion extraction energy. This work is part of a collaboration with the CLIC group, which is working at CERN on high-gradient electron-positron colliders.The authors warmly thank A.D.A.M. S.A. and the Vodafone Foundation for their generous financial support of TERA research activities.Peer reviewe

    Full Scale Proton Beam Impact Testing of new CERN Collimators and Validation of a Numerical Approach for Future Operation

    No full text
    New collimators are being produced at CERN in the framework of a large particle accelerator upgrade project to protect beam lines against stray particles. Their movable jaws hold low density absorbers with tight geometric requirements, while being able to withstand direct proton beam impacts. Such events induce considerable thermo-mechanical loads, leading to complex structural responses, which make the numerical analysis challenging. Hence, an experiment has been developed to validate the jaw design under representative conditions and to acquire online results to enhance the numerical models. Two jaws have been impacted by high-intensity proton beams in a dedicated facility at CERN and have recreated the worst possible scenario in future operation. The analysis of online results coupled to post-irradiation examinations have demonstrated that the jaw response remains in the elastic domain. However, they have also highlighted how sensitive the jaw geometry is to its mounting support inside the collimator. Proton beam impacts, as well as handling activities, may alter the jaw flatness tolerance value by ±\pm 70 μ{\mu}m, whereas the flatness tolerance requirement is 200 μ{\mu}m. In spite of having validated the jaw design for this application, the study points out numerical limitations caused by the difficulties in describing complex geometries and boundary conditions with such unprecedented requirements

    Commissioning of a gantry beamline with rotator at a synchrotron-based ion therapy center

    No full text
    This paper provides an overview of the worldwide first commissioning of a gantry beamline with a rotator at the MedAustron synchrotron-based proton/ion cancer therapy facility in Wiener Neustadt, Austria. The gantry beamline consists of the high energy beam transfer (HEBT) line and the gantry beam transport system. It transports the beam from the synchrotron to the gantry-room isocenter. The HEBT transports the beam from the synchrotron to the gantry entrance, which is the coupling point between the HEBT and the gantry. The rotator is one of the HEBT modules, thus it is an integral part of the gantry beamline. The MedAustron rotator is the worldwide first rotator system used to match slowly extracted asymmetric beams from the synchrotron to the rotating gantry. In this paper, main attention is paid to ion-optical and beam-alignment aspects of the beamline commissioning. A novel orbit-correction and beam-alignment technique has been developed specifically for the beamline with the rotator. While the theoretical concept of the rotator has existed for almost two decades, the MedAustron rotator is the first hardware implementation of this concept all over the world. The presented overview of the beamline commissioning includes a description of the principal technical solutions and main results of the first beam-transport measurements. Since the measured beam size and beam position agree well with theoretical predictions, one can conclude that the proof-of-concept of the rotator-matching has been successfully accomplished
    corecore