8 research outputs found

    Digital Protocol to Record Occlusal Analysis in Prosthodontics: A Pilot Study

    No full text
    Background: Digital technologies enable the accurate replication of occlusion, which is pivotal for stability in maximum intercuspation and dynamic occlusion. CAD softwares generates standardized occlusal morphologies requiring significant adjustments. The consideration of individual mandibular movements during restoration leads to better functional integration. This pilot study evaluates the efficacy of a novel, fully digital protocol for occlusal analysis recording in prosthodontics. Methods: Patients needing single or multiple metal-free restorations were included. Teeth underwent horizontal finish line preparation, while restorations on implants were either directly screwed or used multi-unit abutments. A digital impression (Trios 3 Intraoral Scanner) captured the mouth’s elements. Dynamic occlusion was recorded via Patient Specific Motion (PSM). After the placement and functionalization of temporary restorations, subsequent scans included various elements, and CAD software (Dental system) was used for the restoration design. Restorations were milled in monolithic zirconia, pressed from CAD/CAM-milled wax, and sintered. Results: An evaluation of 52 restorations in 37 patients indicated high accuracy in restorations manufactured via the fully digital workflow. Monolithic zirconia was predominantly used. Subtractive (17.3%) and additive (7.7%) occlusal adjustments were mainly chairside. Conclusion: This study underscores the efficacy of meticulous verification measures and a centric contact system in reducing the need for clinical occlusal refinements in prosthetic restorations

    Clinical evaluation of 1,132 zirconia-based single crowns: A retrospective cohort study from the aiop clinical research group

    No full text
    Purpose: The aim of this retrospective cohort study was to gather the outcomes of zirconia single crowns made by 16 members of the Italian Academy of Prosthetic Dentistry (AIOP) over a time period of up to 5 years. Materials and Methods: A total of 398 patients treated in private practices with 1,132 zirconia-based single-crown restorations made on natural teeth from January 2005 to July 2010 were included. Three hundred forty-three anterior restorations (30.3%) and 789 posterior crowns (69.7%) were made with 16 types of zirconia, using primarily chamfer or knife-edge tooth preparation, and examined according to the esthetic, functional, and biologic criteria. To evaluate the relationship of parafunction with mechanical failure, patients with clenching or bruxism were not excluded from the study group. Results: The cumulative survival rate of all restorations was 98.1%, while the cumulative success rate was 94.3%. Functional criteria had the highest number of failures. The odds ratio (OR) for all restorations was calculated to clarify the relationship between patients who were subject/not subject to parafunctions and technical complications; the OR was 2.60. An association between parafunction and mechanical failure was found in patients with severe parafunction. Conclusions: Porcelain-veneered zirconia single crowns with chamfer and knife-edge preparations showed good clinical results over a period of up to 5 years. Technical complications were few and were limited primarily to patients with parafunction. © 2013 by Quintessence Publishing Co Inc

    Clinical evaluation of tooth-supported zirconia-based fixed dental prostheses: A retrospective cohort study from the AIOP clinical research group

    No full text
    Purpose: The aim of this retrospective cohort study was to evaluate the clinical performance of tooth-supported zirconia-based fixed dental prostheses (FDPs) made by 15 members of the Italian Academy of Prosthetic Dentistry over a time period of up to 5 years. Materials and Methods: Ninety-eight patients were treated with a total of 137 zirconia-based FDPs in anterior and posterior regions using primarily chamfer or knife-edge tooth preparations. The cohort group with parafunctional habits was compared with patients without parafunctional habits according to the esthetic, functional, and biologic United States Public Health Service criteria modified by the FDI World Dental Federation. Results: The estimated cumulative survival of all restorations was 94.70% \ub1 1.25% standard error (SE), whereas the estimated cumulative success decreased to 89.78% \ub1 2.58 SE. Mechanical failures, including three zirconia framework fractures, two hairline cracks, nine chippings, and one delamination of the ceramic veneering, were recorded during the 1-to 5-year observation period. An odds ratio of 2.02 (95% confidence interval: 0.67 to 6.12) showed a moderate association between parafunction and failure. Conclusions: Zirconia-based tooth-supported FDPs showed promising clinical results over a period of up to 5 years. Technical complications were more commonly detected in patients with parafunctional habits

    Clinical evaluation of zirconia-based restorations on implants: a retrospective cohort study from the AIOP clinical research group.

    No full text
    The aim of this retrospective cohort study was to evaluate the clinical performance of zirconia-based implant-supported single crowns and fixed dental prostheses (FDPs) made by 15 members of the Italian Academy of Prosthetic Dentistry (AIOP) over a time period of up to 5 years. MATERIALS AND METHODS: One hundred thirty-one patients were treated with a total of 210 zirconia-based single crowns and FDPs on implants in anterior and posterior regions. A cohort group with parafunctional habits was compared with patients without parafunctional habits according to the esthetic, functional, and biologic United States Public Health Service criteria modified by the FDI World Dental Federation. RESULTS: The estimated cumulative survival (ECS) and standard error (SE) of all restorations on implants was 91.95% \ub1 1.39%, and the estimated cumulative success (ECSs) and SE was 88.37% \ub1 1.72%. The ECS of single crowns and FDPs was 91.25% \ub1 3.69% and 95.23% \ub1 2.28%, respectively, and the estimated cumulative success rates were 88.84% \ub1 2.05% and 87.96% \ub1 3.16%, respectively. Mechanical failures, including four zirconia core fractures, three hairline cracks, four chippings, and five delaminations of the ceramic veneering material, were recorded during a 1- to 5-year observation period. The odds ratio of 3.39 (95% confidence interval: 1.18 to 9.73) showed a moderate association between parafunction and failure. CONCLUSIONS: Zirconiabased implant-supported restorations showed encouraging clinical results over a period of up to 5 years, but more clinical data are needed before these restorations can be considered a viable treatment alternative. Mechanical failures were primarily observed in patients with parafunctions

    Clinical evaluation of 1132 zirconia-based single crowns: a retrospective cohort study from the AIOP clinical research group.

    No full text
    PURPOSE: The aim of this retrospective cohort study was to gather the outcomes of zirconia single crowns made by 16 members of the Italian Academy of Prosthetic Dentistry (AIOP) over a time period of up to 5 years. MATERIALS AND METHODS: A total of 398 patients treated in private practices with 1,132 zirconia-based single-crown restorations made on natural teeth from January 2005 to July 2010 were included. Three hundred forty-three anterior restorations (30.3%) and 789 posterior crowns (69.7%) were made with 16 types of zirconia, using primarily chamfer or knife-edge tooth preparation, and examined according to the esthetic, functional, and biologic criteria. To evaluate the relationship of parafunction with mechanical failure, patients with clenching or bruxism were not excluded from the study group. RESULTS: The cumulative survival rate of all restorations was 98.1%, while the cumulative success rate was 94.3%. Functional criteria had the highest number of failures. The odds ratio (OR) for all restorations was calculated to clarify the relationship between patients who were subject/not subject to parafunctions and technical complications; the OR was 2.60. An association between parafunction and mechanical failure was found in patients with severe parafunction. CONCLUSIONS: Porcelain-veneered zirconia single crowns with chamfer and knife-edge preparations showed good clinical results over a period of up to 5 years. Technical complications were few and were limited primarily to patients with parafunctio

    Clinical evaluation of tooth-supported zirconia-based fixed dental prostheses: a retrospective cohort study from the AIOP clinical research group

    No full text
    The aim of this retrospective cohort study was to evaluate the clinical performance of tooth-supported zirconia-based fixed dental prostheses (FDPs) made by 15 members of the Italian Academy of Prosthetic Dentistry over a time period of up to 5 years. MATERIALS AND METHODS: Ninety-eight patients were treated with a total of 137 zirconia-based FDPs in anterior and posterior regions using primarily chamfer or knife-edge tooth preparations. The cohort group with parafunctional habits was compared with patients without parafunctional habits according to the esthetic, functional, and biologic United States Public Health Service criteria modified by the FDI World Dental Federation. RESULTS: The estimated cumulative survival of all restorations was 94.70% \ub1 1.25% standard error (SE), whereas the estimated cumulative success decreased to 89.78% \ub1 2.58 SE. Mechanical failures, including three zirconia framework fractures, two hairline cracks, nine chippings, and one delamination of the ceramic veneering, were recorded during the 1- to 5-year observation period. An odds ratio of 2.02 (95% confidence interval: 0.67 to 6.12) showed a moderate association between parafunction and failure. CONCLUSIONS: Zirconia-based tooth-supported FDPs showed promising clinical results over a period of up to 5 years. Technical complications were more commonly detected in patients with parafunctional habits

    Clinical evaluation of zirconia-based restorations on implants: A retrospective cohort study from the AIOP clinical research group

    No full text
    Purpose: The aim of this retrospective cohort study was to evaluate the clinical performance of zirconia-based implant-supported single crowns and fixed dental prostheses (FDPs) made by 15 members of the Italian Academy of Prosthetic Dentistry (AIOP) over a time period of up to 5 years. Materials and Methods: One hundred thirtyone patients were treated with a total of 210 zirconia-based single crowns and FDPs on implants in anterior and posterior regions. A cohort group with parafunctional habits was compared with patients without parafunctional habits according to the esthetic, functional, and biologic United States Public Health Service criteria modified by the FDI World Dental Federation. Results: The estimated cumulative survival (ECS) and standard error (SE) of all restorations on implants was 91.95% \ub1 1.39%, and the estimated cumulative success (ECSs) and SE was 88.37% \ub1 1.72%. The ECS of single crowns and FDPs was 91.25% \ub1 3.69% and 95.23% \ub1 2.28%, respectively, and the estimated cumulative success rates were 88.84% \ub1 2.05% and 87.96% \ub1 3.16%, respectively. Mechanical failures, including four zirconia core fractures, three hairline cracks, four chippings, and five delaminations of the ceramic veneering material, were recorded during a 1-to 5-year observation period. The odds ratio of 3.39 (95% confidence interval: 1.18 to 9.73) showed a moderate association between parafunction and failure. Conclusions: Zirconiabased implant-supported restorations showed encouraging clinical results over a period of up to 5 years, but more clinical data are needed before these restorations can be considered a viable treatment alternative. Mechanical failures were primarily observed in patients with parafunctions

    Internal- vs external-connection single implants: A retrospective study in an italian population treated by certified prosthodontists

    No full text
    Purpose: The design of an implant connection that allows prosthetic suprastructures to be attached to implants has long been debated in the dental literature. The goal of this retrospective study was to evaluate the 5-year clinical results for a large number of single implants restored by certified prosthodontists in an attempt to establish whether different clinical outcomes could be detected for external- or internalconnection implants. Materials and Methods: All single implants with internal or external connections inserted in 27 private dental practices from January 1, 2003 to December 31, 2007 were evaluated. An initial statistical analysis was performed to describe the sample population at baseline and then to compare the two types of implant-abutment connection configurations and their clinical outcomes. All data were statistically analyzed with STATA12 (StataCorp). Results: Twenty-eight of the 85 active members of the Italian Academy of Prosthetic Dentistry (AIOP) participated in this study. The sample included 1,159 patients and 2,010 implants. Of the implants, 75 were dropped because there was no information about follow-up. Of the remaining implants, 1,431 (74.0%) were followed for at least 5 years, and 332 implants (17.2%) were followed for more than 8 years. Nearly 99% (98.9%) of the implants survived. The difference between the survival frequencies of the two types of implant-abutment connection configurations was not significant for each negative event (log-rank test, P > .05). There was no difference between the two types of implants regarding restoration fracture, implant screw loosening, and peri-implant disease. Conclusion: Within the limitations of this study, it can be suggested that there is no difference in clinical outcomes of single restorations joined to internal- or external-connection implants
    corecore