186 research outputs found

    Statistical Diagnosis Method of Conductor Motions in Superconducting Magnets to Predict their Quench Performance

    Get PDF
    Premature training quenches are usually caused by the transient energy released within the magnet coil as it is energised. Two distinct varieties of disturbances exist. They are thought to be electrical and mechanical in origin. The first type of disturbance comes from non-uniform current distribution in superconducting cables whereas the second one usually originates from conductor motions or micro-fractures of insulating materials under the action of Lorentz forces. All of these mechanical events produce in general a rapid variation of the voltages in the so-called quench antennas and across the magnet coil, called spikes. A statistical method to treat the spatial localisation and the time occurrence of spikes will be presented. It allows identification of the mechanical weak points in the magnet without need to increase the current to provoke a quench. The prediction of the quench level from detailed analysis of the spike statistics can be expected

    Orchestrating the measurements on twelve magnet test benches

    Get PDF
    The final LHC dipole series test set-up will consist of 12 benches, organised in 6 clusters of two benches sharing the largest and most expensive devices. This sharing is made possible by a deliberate de-phasing of the tests among magnets, ensuring an optimum use of resources, such as cryogenics and power equipment, without limiting the total throughput. To orchestrate the measurements a Test Master is needed to organise the tests per cluster and a Resource Manager to centralise the booking of the resources

    A VME-based LabVIEW system for the magnetic measurements of the LHC prototype dipoles

    Get PDF
    A magnetic measurement system based on a set of rotating harmonic coils has been integrated together with the coil positioning and rotation control, the associated data acquisition and the power supply control using a PC. This PC is a mono-board VME module with its networking connection, local hard disk and serial interfaces. The PC communicates with its peripheral devices (the controller embedded in the power converter, the coil positioning PLC and the coil rotation hardware) via RS-232C lines and acquires data using VME modules: in-house designed voltage integrators for the magnetic measurement and a commercial ADC for real-time measurements. The software is a LabVIEW application: it handles and synchronizes the peripheral devices of the measurement system and the real-time tasks related to the data acquisition; it constitutes a man-machine interface for the operator and also directly stores field maps onto a file server. The system is operational on the test benches and has proved reliable, user-friendly and performed as expected.

    A Mole for Warm Magnetic and Optical Measurements of LHC Dipoles

    Get PDF
    A new rotating coil probe (a mole) has been developed for the simultaneous measurement of the magnetic field and magnetic axis of warm superconducting LHC dipoles and associated corrector windings. The mole houses a radial rotating coil and travels inside the magnet aperture by means of an externally driven two-way traction belt. The coil is rotated by an on-board piezo motor, being tested in view of future devices for cold measurements as the only type of motor compatible with strong magnetic fields. A virtual light spot is generated in the coil center by a LED source. The position of this light spot is measured from the outside by a system including a telescope, a CCD camera and a DSP. Jigs on reference granite tables are used to transfer the optical measurements to the magnet fiducials. We describe here the main characteristics and performance of the mol

    The LHC Post Mortem Analysis Framework

    Get PDF
    The LHC with its unprecedented complexity and criticality of beam operation will need thorough analysis of data taken from systems such as power converters, interlocks and beam instrumentation during events like magnet quenches and beam loss. The causes of beam aborts or in the worst case equipment damage have to be revealed to improve operational procedures and protection systems. The correct functioning of the protection systems with their required redundancy has to be verified after each such event. Post mortem analysis software for the control room has been prepared with automated analysis packages in view of the large number of systems and data volume. This paper recalls the requirements for the LHC Beam Post Mortem System (PM) and the necessity for highly reliable data collection. It describes in detail the redundant architecture for data collection as well as the chosen implementation of a multi-level analysis framework, allowing for automated analysis and qualification of a beam dump event based on expert provided analysis modules. It concludes with an example of the data taken during first beam tests in September 2008 with a first version of the system

    Twin Rotating Coils for Cold Magnetic Measurements of 15 m Long LHC Dipoles

    Get PDF
    We describe here a new harmonic coil system for the field measurement of the superconducting, twin aperture LHC dipoles and the associated corrector magnets. Besides field measurements the system can be used as an antenna to localize the quench origin. The main component is a 16 m long rotating shaft, made up of 13 ceramic segments, each carrying two tangential coils plus a central radial coil, all working in parallel. The segments are connected with flexible Ti-alloy bellows, allowing the piecewise straight shaft to follow the curvature of the dipole while maintaining high torsional rigidity. At each interconnection the structure is supported by rollers and ball bearings, necessary for the axial movement for installation and for the rotation of the coil during measurement. Two such shafts are simultaneously driven by a twin-rotating unit, thus measuring both apertures of a dipole at the same time. This arrangement allows very short measurement times (typically 10 s) and is essential to perform cold magnetic measurements of all dipoles. The coil surface and direction are calibrated using a reference dipole. In this paper we describe the twin rotating coil system and its calibration facility, and we give the typical resolution and accuracy achieved with the first commissioned unit

    First Powering of the LHC Test String 2

    Get PDF
    String 2 is a full-size model of a regular cell in an LHC arc. In the first phase, three dipole magnets and two quadrupole magnets have been assembled in String 2 and commissioning started in April 2001. By the beginning of 2002 three pre-series dipole magnets will be added to complete the cell. As for its predecessor String 1, the facility was built to individually validate the LHC systems and to investigate their collective behaviour for normal operation with the magnets at a temperature of 1.9 K, during transients as well as during exceptional conditions. String 2 is a precious milestone before installation and commissioning of the first LHC sector (1/8 of the machine) in 2004, with respect to infrastructure, installation, tooling and assembly procedures, testing and commissioning of individual systems, as well as the global commissioning of the technical systems. This paper describes the commissioning, and retraces the first powering history

    Experiments and cycling at the LHC prototype helf-cell

    Get PDF
    The first version of the LHC prototype half-cell has been in operation since February 1995. It consists of one quadrupole and three 10-m twin aperture dipole magnets which operate at 1.8 K. This experimental set-up has been used to observe and study phenomena which appear when the systems are assembled in one unit and influence one another. The 18-month long experimental program has validated the cryogenic system and yielded a number of results on cryogenic instrumentation, magnet protection and vacuum in particular under non-standard operating conditions. The program was recently complemented by the cycling experiment: it consisted in powering the magnets following the ramp rates which will be experienced by the magnets during an LHC acceleration. In order to simulate 10 years of routine operation of LHC, more than 2000 1-hour cycles were performed interleaved with provoked quenches. The objective of this experiment was to reveal eventual flaws in the design of components. The prototype half-cell performed to expectations showing no sign of failure of fatigue of components for more than 2000 cycles until one of the dipoles started exhibiting an erratic quench behavior
    • …
    corecore