64 research outputs found

    Levels of Fibrinogen Variants Are Altered in Severe COVID-19

    Get PDF
    Background  Fibrinogen variants as a result of alternative messenger RNA splicing or protein degradation can affect fibrin(ogen) functions. The levels of these variants might be altered during coronavirus disease 2019 (COVID-19), potentially affecting disease severity or the thrombosis risk. Aim  To investigate the levels of fibrinogen variants in plasma of patients with COVID-19. Methods  In this case-control study, we measured levels of functional fibrinogen using the Clauss assay. Enzyme-linked immunosorbent assays were used to measure antigen levels of total, intact (nondegraded Aα chain), extended Aα chain (α E ), and γ' fibrinogen in healthy controls, patients with pneumococcal infection in the intensive care unit (ICU), ward patients with COVID-19, and ICU patients with COVID-19 (with and without thrombosis, two time points). Results  Healthy controls and ward patients with COVID-19 ( n  = 10) showed similar fibrinogen (variant) levels. ICU patients with COVID-19 who later did ( n  = 19) or did not develop thrombosis ( n  = 18) and ICU patients with pneumococcal infection ( n  = 6) had higher absolute levels of functional, total, intact, and α E fibrinogen than healthy controls ( n  = 7). The relative α E fibrinogen levels were higher in ICU patients with COVID-19 than in healthy controls, while relative γ' fibrinogen levels were lower. After diagnosis of thrombosis, only the functional fibrinogen levels were higher in ICU patients with COVID-19 and thrombosis than in those without, while no differences were observed in the other fibrinogen variants. Conclusion  Our results show that severe COVID-19 is associated with increased levels of α E fibrinogen and decreased relative levels of γ' fibrinogen, which may be a cause or consequence of severe disease, but this is not associated with the development of thrombosis.</p

    Levels of Fibrinogen Variants Are Altered in Severe COVID-19

    Get PDF
    Background  Fibrinogen variants as a result of alternative messenger RNA splicing or protein degradation can affect fibrin(ogen) functions. The levels of these variants might be altered during coronavirus disease 2019 (COVID-19), potentially affecting disease severity or the thrombosis risk. Aim  To investigate the levels of fibrinogen variants in plasma of patients with COVID-19. Methods  In this case-control study, we measured levels of functional fibrinogen using the Clauss assay. Enzyme-linked immunosorbent assays were used to measure antigen levels of total, intact (nondegraded Aα chain), extended Aα chain (α E ), and γ' fibrinogen in healthy controls, patients with pneumococcal infection in the intensive care unit (ICU), ward patients with COVID-19, and ICU patients with COVID-19 (with and without thrombosis, two time points). Results  Healthy controls and ward patients with COVID-19 ( n  = 10) showed similar fibrinogen (variant) levels. ICU patients with COVID-19 who later did ( n  = 19) or did not develop thrombosis ( n  = 18) and ICU patients with pneumococcal infection ( n  = 6) had higher absolute levels of functional, total, intact, and α E fibrinogen than healthy controls ( n  = 7). The relative α E fibrinogen levels were higher in ICU patients with COVID-19 than in healthy controls, while relative γ' fibrinogen levels were lower. After diagnosis of thrombosis, only the functional fibrinogen levels were higher in ICU patients with COVID-19 and thrombosis than in those without, while no differences were observed in the other fibrinogen variants. Conclusion  Our results show that severe COVID-19 is associated with increased levels of α E fibrinogen and decreased relative levels of γ' fibrinogen, which may be a cause or consequence of severe disease, but this is not associated with the development of thrombosis.</p

    Short-Term Outcomes of Secondary Liver Surgery for Initially Unresectable Colorectal Liver Metastases following Modern Induction Systemic Therapy in the Dutch CAIRO5 Trial

    Get PDF
    Objective: To present short-term outcomes of liver surgery in patients with initially unresectable colorectal liver metastases (CRLM) downsized by chemotherapy plus targeted agents. Background: The increase of complex hepatic resections of CRLM, technical innovations pushing boundaries of respectability, and use of intensified induction systemic regimens warrant for safety data in a homogeneous multicenter prospective cohort. Methods: Patients with initially unresectable CRLM, who underwent complete resection after induction systemic regimens with doublet or triplet chemotherapy, both plus targeted therapy, were selected from the ongoing phase III CAIRO5 study (NCT02162563). Short-term outcomes and risk factors for severe postoperative morbidity (Clavien Dindo grade ≥ 3) were analyzed using logistic regression analysis. Results: A total of 173 patients underwent resection of CRLM after induction systemic therapy. The median number of metastases was 9 and 161 (93%) patients had bilobar disease. Thirty-six (20.8%) 2-stage resections and 88 (51%) major resections (>3 liver segments) were performed. Severe postoperative morbidity and 90-day mortality was 15.6% and 2.9%, respectively. After multivariable analysis, blood transfusion (odds ratio [OR] 2.9 [95% confidence interval (CI) 1.1-6.4], P = 0.03), major resection (OR 2.9 [95% CI 1.1-7.5], P = 0.03), and triplet chemotherapy (OR 2.6 [95% CI 1.1-7.5], P = 0.03) were independently correlated with severe postoperative complications. No association was found between number of cycles of systemic therapy and severe complications (r = -0.038, P = 0.31). Conclusion: In patients with initially unresectable CRLM undergoing modern induction systemic therapy and extensive liver surgery, severe postoperative morbidity and 90-day mortality were 15.6% and 2.7%, respectively. Triplet chemotherapy, blood transfusion, and major resections were associated with severe postoperative morbidity

    Maternal and neonatal outcomes in planned versus emergency cesarean delivery for placenta accreta spectrum: A multinational database study

    Get PDF
    Introduction: Placenta accreta spectrum (PAS) is a condition often resulting in severe maternal morbidity. Scheduled delivery by an experienced team has been shown to improve maternal outcomes; however, the benefits must be weighed against the risk of iatrogenic prematurity. The aim of this study is to investigate the rates of emergency delivery seen for antenatally suspected PAS and compare the resulting outcomes in the 15 referral centers of the International Society for PAS (IS-PAS). Material and methods: Fifteen centers provided cases between 2008 and 2019. The women included were divided into two groups according to whether they had a planned or an emergency cesarean delivery. Delivery was defined as "planned" when performed at a time and date to suit the team. All the remaining cases were classified as "emergency". Maternal characteristics and neonatal outcomes were compared between the two groups according to gestation at delivery. Results: In all, 356 women were included. Of these, 239 (67%) underwent a planned delivery and 117 (33%) an emergency delivery. Vaginal bleeding was the indication for emergency delivery in 41 of the 117 women (41%). There were no significant differences in terms of blood loss, transfusion rates or major maternal morbidity between planned and emergency deliveries. However, the rate of maternal intensive therapy unit admission was increased with emergency delivery (45% vs 33%, P = .02). Antepartum hemorrhage was the only independent predictor of emergency delivery (aOR: 4.3, 95% confidence interval 2.4-7.7). Emergency delivery due to vaginal bleeding was more frequent with false-positive cases (antenatally suspected but not confirmed as PAS at delivery) and the milder grades of PAS (accreta/increta). The rate of infants experiencing any major neonatal morbidity was 25% at 34+1 to 36+0 weeks and 19% at >36+0 weeks. Conclusions: Emergency delivery in centers of excellence did not increase blood loss, transfusion rates or maternal morbidity. The single greatest risk factor for emergency delivery was antenatal hemorrhage. When adequate expertise and resources are available, to defer delivery in women with no significant antenatal bleeding and no risk factors for pre-term birth until >36+0 weeks can be considered to improve fetal outcomes. Further studies are needed to investigate this fully

    Association of peripartum management and high maternal blood loss at cesarean delivery for placenta accreta spectrum (PAS): A multinational database study

    Get PDF
    Introduction: Placenta accreta spectrum (PAS) carries a high burden of adverse maternal outcomes, especially significant blood loss, which can be life-threatening. Different management strategies have been proposed but the association of clinical risk factors and surgical management options during cesarean delivery with high blood loss is not clear. Material and methods: In this international multicenter study, 338 women with PAS undergoing cesarean delivery were included. Fourteen European and one non-European center (USA) provided cases treated retrospectively between 2008 and 2014 and prospectively from 2014 to 2019. Peripartum blood loss was estimated visually and/or by weighing and measuring of volume. Participants were grouped based on blood loss above or below the 75th percentile (>3500 ml) and the 90th percentile (>5500 ml). Results: Placenta percreta was found in 58% of cases. Median blood loss was 2000 ml (range: 150-20 000 ml). Unplanned hysterectomy was associated with an increased risk of blood loss >3500 ml when compared with planned hysterectomy (adjusted OR [aOR] 3.7 [1.5-9.4], p = 0.01). Focal resection was associated with blood loss comparable to that of planned hysterectomy (crude OR 0.7 [0.2-2.1], p = 0.49). Blood loss >3500 ml was less common in patients undergoing successful conservative management (placenta left in situ, aOR 0.1 [0.0-0.6], p = 0.02) but was more common in patients who required delayed hysterectomy (aOR 6.5 [1.7-24.4], p = 0.001). Arterial occlusion methods (uterine or iliac artery ligation, embolization or intravascular balloons), application of uterotonic medication or tranexamic acid showed no significant effect on blood loss >3500 ml. Patients delivered by surgeons without experience in PAS were more likely to experience blood loss >3500 ml (aOR 3.0 [1.4-6.4], p = 0.01). Conclusions: In pregnant women with PAS, the likelihood of blood loss >3500 ml was reduced in planned vs unplanned cesarean delivery, and when the surgery was performed by a specialist experienced in the management of PAS. This reinforces the necessity of delivery by an expert team. Conservative management was also associated with less blood loss, but only if successful. Therefore, careful patient selection is of great importance. Our study showed no consistent benefit of other adjunct measures such as arterial occlusion techniques, uterotonics or tranexamic acid

    Novel role of cPLA2α in membrane and actin dynamics

    Get PDF
    Actin-directed processes such as membrane ruffling and cell migration are regulated by specific signal transduction pathways that become activated by growth factor receptors. The same signaling pathways that lead to modifications in actin dynamics also activate cPLA2α. Moreover, arachidonic acid, the product of cPLA2α activity, is involved in regulation of actin dynamics. Therefore, it was investigated whether cPLA2α plays a role in actin dynamics, more specifically during growth factor-induced membrane ruffling and cell migration. Upon stimulation of ruffling and cell migration by growth factors, endogenous cPLA2α and its active phosphorylated form were shown to relocate at protrusions of the cell membrane involved in actin and membrane dynamics. Inhibition of cPLA2α activity with specific inhibitors blocked growth factor-induced membrane and actin dynamics, suggesting an important role for cPLA2α in these processes

    Prognostic value of total tumor volume in patients with colorectal liver metastases:A secondary analysis of the randomized CAIRO5 trial with external cohort validation

    Get PDF
    Background:This study aimed to assess the prognostic value of total tumor volume (TTV) for early recurrence (within 6 months) and overall survival (OS) in patients with colorectal liver metastases (CRLM), treated with induction systemic therapy followed by complete local treatment.Methods: Patients with initially unresectable CRLM from the multicenter randomized phase 3 CAIRO5 trial (NCT02162563) who received induction systemic therapy followed by local treatment were included. Baseline TTV and change in TTV as response to systemic therapy were calculated using the CT scan before and the first after systemic treatment, and were assessed for their added prognostic value. The findings were validated in an external cohort of patients treated at a tertiary center. Results:In total, 215 CAIRO5 patients were included. Baseline TTV and absolute change in TTV were significantly associated with early recurrence (P = 0.005 and P = 0.040, respectively) and OS in multivariable analyses (P = 0.024 and P = 0.006, respectively), whereas RECIST1.1 was not prognostic for early recurrence (P = 0.88) and OS (P = 0.35). In the validation cohort (n = 85), baseline TTV and absolute change in TTV remained prognostic for early recurrence (P = 0.041 and P = 0.021, respectively) and OS in multivariable analyses (P &lt; 0.0001 and P = 0.012, respectively), and showed added prognostic value over conventional clinicopathological variables (increase C-statistic, 0.06; 95 % CI, 0.02 to 0.14; P = 0.008). Conclusion: Total tumor volume is strongly prognostic for early recurrence and OS in patients who underwent complete local treatment of initially unresectable CRLM, both in the CAIRO5 trial and the validation cohort. In contrast, RECIST1.1 did not show prognostic value for neither early recurrence nor OS.</p
    corecore