151 research outputs found

    3-D printing quantization predistortion applied to sub-THz chained-function filters

    Get PDF
    This paper investigates physical dimension limits associated with the low-cost, polymer-based masked stereolithography apparatus (MSLA) 3-D printer, with 50 μm pixels defining the minimum print feature size. Based on the discretization properties of our MSLA 3-D printer, multi-step quantization predistortion is introduced to correct for registration errors between the CAD drawing and slicing software. This methodology is applied to G-band 5th order metal-pipe rectangular waveguide filters, where the pixel pitch has an equivalent electrical length of 8.5° at center frequency. When compared to the reference Chebyshev filter, our chained-function filter exhibits superior S-parameter measurements, with a low insertion loss of only 0.6 dB at its center frequency of 182 GHz, having a 0.9% frequency shift, and an acceptable worst-case passband return loss of 13 dB. Moreover, with measured dimensions after the 3-D printed parts have been commercially electroplated with a 50 μm thick layer of copper, the re-simulations are in good agreement with the S-parameter measurements. For the first time, systematic (quantization) errors associated with a pixel-based 3-D printer have been characterized and our robust predistortion methodology has been successfully demonstrated with an upper-millimeter-wave circuit. Indeed, we report the first polymer-based 3-D printed filters that operate above W-band. As pixel sizes continue to shrink, more resilient (sub-)THz filters with ever-higher frequencies of operation and more demanding specifications can be 3-D printed. Moreover, our work opens-up new opportunities for any pixel-based technology, which exhibits registration errors, with its application critically dependent on its minimum feature size

    Polymer-based 3-D printed 140 to 220 GHz metal waveguide thru lines, twist and filters

    Get PDF
    This paper demonstrates the current state-of-the-art in low-cost, low loss ruggedized polymer-based 3-D printed G-band (140 to 220 GHz) metal-pipe rectangular waveguide (MPRWG) components. From a unique and exhaustive up-to-date literature review, the main limitations for G-band split-block MPRWGs are identified as electromagnetic (EM) radiation leakage, assembly part alignment and manufacturing accuracy. To mitigate against leakage and misalignment, we investigate a ‘trough-and-lid’ split-block solution. This approach is successfully employed in proof-of-concept thru lines, and in the first polymer-based 3-D printed 90° twist and symmetrical diaphragm inductive iris-coupled bandpass filters (BPFs) operating above 110 GHz. An inexpensive desktop masked stereolithography apparatus 3-D printer and a commercial copper electroplating service are used. Surface roughness losses are calculated and applied to EM (re-)simulations, using two modifications of the Hemispherical model. The 7.4 mm thru line exhibits a measured average dissipative attenuation of only 12.7 dB/m, with rectangular-to-trapezoidal cross-sectional distortion being the main contributor to loss. The 90° twist exhibits commensurate measured performance to its commercial counterpart, despite the much lower manufacturing costs. A detailed time-domain reflectometry analysis of flange quality for the thru lines and 90° twists has also been included. Finally, a new systematic iris corner rounding compensation technique, to correct passband frequency down-shifting is applied to two BPFs. Here, the 175 GHz exemplar exhibits only 0.5% center frequency up-shifting. The trough-and-lid assembly is now a viable solution for new upper-mm-wave MPRWG components. With this technology becoming less expensive and more accurate, higher frequencies and/or more demanding specifications can be implemented

    3-D printed rectangular waveguide 123-129 GHz packaging for commercial CMOS RFICs

    Get PDF
    This work demonstrates the hybrid integration of a complementary metal–oxide–semiconductor (CMOS) radio frequency integrated circuit (RFIC) into a host 3-D printed metal-pipe rectangular waveguide (MPRWG). On-chip Vivaldi antennas are used for TE 10 -to-thin-film microstrip (TFMS) mode conversion. Our packaging solution has a combined measured insertion loss of only 1 dB/transition at 126 GHz. This unique packaging and interconnect solution opens up new opportunities for implementing low-cost subterahertz (THz) multichip modules

    3-D Printed Plug and Play Prototyping for Low-cost Sub-THz Subsystems

    Get PDF
    Polymer-based additive manufacturing using 3-D printing for upper-millimeter-wave ( ca. 100 to 300 GHz) frequency applications is now emerging. Building on our previous work, with metal-pipe rectangular waveguides and free-space quasi-optical components, this paper brings the two media together at G-band (140 to 220 GHz), by demonstrating a compact multi-channel front-end subsystem. Here, the proof-of-concept demonstrator integrates eight different types of 3-D printed components (30 individual components in total). In addition, the housing for two test platforms and the subsystem are all 3-D printed as single pieces, to support plug and play development; offering effortless component assembly and alignment. We introduce bespoke free-space TRM calibration and measurement schemes with our quasi-optical test platforms. Equal power splitting plays a critical role in our multi-channel application. Here, we introduce a broadband 3-D printed quasi-optical beamsplitter for upper-millimeter-wave applications. Our quantitative and/or qualitative performance evaluations for individual components and the complete integrated subsystem, demonstrate the potential for using consumer-level desktop 3-D printing technologies at such high frequencies. This work opens-up new opportunities for low-cost, rapid prototyping and small-batch production of complete millimeter-wave front-end subsystems

    Graphene-based waveguide resonators for submillimeter-wave applications

    Get PDF
    Utilization of graphene covered waveguide inserts to form tunable waveguide resonators is theoretically explained and rigorously investigated by means of full-wave numerical electromagnetic simulations. Instead of using graphene-based switching elements, the concept we propose incorporates graphene sheets as parts of a resonator. Electrostatic tuning of the graphene surface conductivity leads to changes in the electromagnetic field boundary conditions at the resonator edges and surfaces, thus producing an effect similar to varying the electrical length of a resonator. The presented outline of the theoretical background serves to give phenomenological insight into the resonator behavior, but it can also be used to develop customized software tools for design and optimization of graphene-based resonators and filters. Due to the linear dependence of the imaginary part of the graphene surface impedance on frequency, the proposed concept was expected to become effective for frequencies above 100 GHz, which is confirmed by the numerical simulations. A frequency range from 100 GHz up to 1100 GHz, where the rectangular waveguides are used, is considered. Simple, all-graphene-based resonators are analyzed first, to assess the achievable tunability and to check the performance throughout the considered frequency range. Graphene–metal combined waveguide resonators are proposed in order to preserve the excellent quality factors typical for the type of waveguide discontinuities used. Dependence of resonator properties on key design parameters is studied in detail. Dependence of resonator properties throughout the frequency range of interest is studied using eight different waveguide sections appropriate for different frequency intervals. Proposed resonators are aimed at applications in the submillimeter-wave spectral region, serving as the compact tunable components for the design of bandpass filters and other devices

    Low temperature decreases bone mass in mice: Implications for humans

    Full text link
    ObjectivesHumans exhibit significant ecogeographic variation in bone size and shape. However, it is unclear how significantly environmental temperature influences cortical and trabecular bone, making it difficult to recognize adaptation versus acclimatization in past populations. There is some evidence that cold‐induced bone loss results from sympathetic nervous system activation and can be reduced by nonshivering thermogenesis (NST) via uncoupling protein (UCP1) in brown adipose tissue (BAT). Here we test two hypotheses: (1) low temperature induces impaired cortical and trabecular bone acquisition and (2) UCP1, a marker of NST in BAT, increases in proportion to degree of low‐temperature exposure.MethodsWe housed wildtype C57BL/6J male mice in pairs at 26 °C (thermoneutrality), 22 °C (standard), and 20 °C (cool) from 3 weeks to 6 or 12 weeks of age with access to food and water ad libitum (N = 8/group).ResultsCool housed mice ate more but had lower body fat at 20 °C versus 26 °C. Mice at 20 °C had markedly lower distal femur trabecular bone volume fraction, thickness, and connectivity density and lower midshaft femur cortical bone area fraction versus mice at 26 °C (p < .05 for all). UCP1 expression in BAT was inversely related to temperature.DiscussionThese results support the hypothesis that low temperature was detrimental to bone mass acquisition. Nonshivering thermogenesis in brown adipose tissue increased in proportion to low‐temperature exposure but was insufficient to prevent bone loss. These data show that chronic exposure to low temperature impairs bone architecture, suggesting climate may contribute to phenotypic variation in humans and other hominins.Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/146428/1/ajpa23684.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/146428/2/ajpa23684_am.pd

    Segmentation of epidermal tissue with histopathological damage in images of haematoxylin and eosin stained human skin.

    Get PDF
    Background: Digital image analysis has the potential to address issues surrounding traditional histological techniques including a lack of objectivity and high variability, through the application of quantitative analysis. A key initial step in image analysis is the identification of regions of interest. A widely applied methodology is that of segmentation. This paper proposes the application of image analysis techniques to segment skin tissue with varying degrees of histopathological damage. The segmentation of human tissue is challenging as a consequence of the complexity of the tissue structures and inconsistencies in tissue preparation, hence there is a need for a new robust method with the capability to handle the additional challenges materialising from histopathological damage.Methods: A new algorithm has been developed which combines enhanced colour information, created following a transformation to the L*a*b* colourspace, with general image intensity information. A colour normalisation step is included to enhance the algorithm's robustness to variations in the lighting and staining of the input images. The resulting optimised image is subjected to thresholding and the segmentation is fine-tuned using a combination of morphological processing and object classification rules. The segmentation algorithm was tested on 40 digital images of haematoxylin & eosin (H&E) stained skin biopsies. Accuracy, sensitivity and specificity of the algorithmic procedure were assessed through the comparison of the proposed methodology against manual methods.Results: Experimental results show the proposed fully automated methodology segments the epidermis with a mean specificity of 97.7%, a mean sensitivity of 89.4% and a mean accuracy of 96.5%. When a simple user interaction step is included, the specificity increases to 98.0%, the sensitivity to 91.0% and the accuracy to 96.8%. The algorithm segments effectively for different severities of tissue damage.Conclusions: Epidermal segmentation is a crucial first step in a range of applications including melanoma detection and the assessment of histopathological damage in skin. The proposed methodology is able to segment the epidermis with different levels of histological damage. The basic method framework could be applied to segmentation of other epithelial tissues

    A resting state network in the motor control circuit of the basal ganglia

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In the absence of overt stimuli, the brain shows correlated fluctuations in functionally related brain regions. Approximately ten largely independent resting state networks (RSNs) showing this behaviour have been documented to date. Recent studies have reported the existence of an RSN in the basal ganglia - albeit inconsistently and without the means to interpret its function. Using two large study groups with different resting state conditions and MR protocols, the reproducibility of the network across subjects, behavioural conditions and acquisition parameters is assessed. Independent Component Analysis (ICA), combined with novel analyses of temporal features, is applied to establish the basis of signal fluctuations in the network and its relation to other RSNs. Reference to prior probabilistic diffusion tractography work is used to identify the basal ganglia circuit to which these fluctuations correspond.</p> <p>Results</p> <p>An RSN is identified in the basal ganglia and thalamus, comprising the pallidum, putamen, subthalamic nucleus and substantia nigra, with a projection also to the supplementary motor area. Participating nuclei and thalamo-cortical connection probabilities allow this network to be identified as the motor control circuit of the basal ganglia. The network was reproducibly identified across subjects, behavioural conditions (fixation, eyes closed), field strength and echo-planar imaging parameters. It shows a frequency peak at 0.025 ± 0.007 Hz and is most similar in spectral composition to the Default Mode (DM), a network of regions that is more active at rest than during task processing. Frequency features allow the network to be classified as an RSN rather than a physiological artefact. Fluctuations in this RSN are correlated with those in the task-positive fronto-parietal network and anticorrelated with those in the DM, whose hemodynamic response it anticipates.</p> <p>Conclusion</p> <p>Although the basal ganglia RSN has not been reported in most ICA-based studies using a similar methodology, we demonstrate that it is reproducible across subjects, common resting state conditions and imaging parameters, and show that it corresponds with the motor control circuit. This characterisation of the basal ganglia network opens a potential means to investigate the motor-related neuropathologies in which the basal ganglia are involved.</p

    Colorization and Automated Segmentation of Human T2 MR Brain Images for Characterization of Soft Tissues

    Get PDF
    Characterization of tissues like brain by using magnetic resonance (MR) images and colorization of the gray scale image has been reported in the literature, along with the advantages and drawbacks. Here, we present two independent methods; (i) a novel colorization method to underscore the variability in brain MR images, indicative of the underlying physical density of bio tissue, (ii) a segmentation method (both hard and soft segmentation) to characterize gray brain MR images. The segmented images are then transformed into color using the above-mentioned colorization method, yielding promising results for manual tracing. Our color transformation incorporates the voxel classification by matching the luminance of voxels of the source MR image and provided color image by measuring the distance between them. The segmentation method is based on single-phase clustering for 2D and 3D image segmentation with a new auto centroid selection method, which divides the image into three distinct regions (gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) using prior anatomical knowledge). Results have been successfully validated on human T2-weighted (T2) brain MR images. The proposed method can be potentially applied to gray-scale images from other imaging modalities, in bringing out additional diagnostic tissue information contained in the colorized image processing approach as described
    corecore