5 research outputs found

    Observations on hearing preservation in patients with hybrid-L electrode implanted at Poznan University of Medical Sciences in Poland

    Get PDF
    The objective of the paper is to evaluate the hearing preservation rate in patients with high frequency hearing loss, treated with Cochlear Nucleus Freedom Hybrid-L implant in the Otolaryngology Department, Poznan University of Medical Sciences in Poland. Study was designed as the retrospective analysis. Twenty-one patients were operated and implanted with Nucleus Freedom Hybrid-L implant. Pure tone thresholds were recorded prior to the surgery and at the time of speech processor switch-on. Patients were subdivided into two groups with respect to their PTA thresholds: group A—classic indications and group B—extended indications. Average PTA for three frequencies (250, 500, 1,000 Hz) were calculated for each patient pre- and postoperatively. In the group of 21 implanted patients in 17 cases we have observed preservation of hearing (12 patients from group A, 5 patients from group B) with a mean value of 13.1 dB. In 4 out of 21 patients deafness on the implanted ear was noted. Our results clearly indicate that with standard procedure hearing preservation can be obtained in majority of patients. Hearing preservation was not achieved in 19 %, but owing to design of the electrode of the Cochlear Nucleus Hybrid-L that enables to work as CI platform alone, in patients who lost their hearing after surgery re-implantations were not required. This proves that EAS is a safe and reliable method to help patients with specific type of hearing loss

    The evaluation of a surgery and the short-term benefits of a new active bone conduction hearing implant - the Osia®

    Get PDF
    Introduction: Modern medicine offers a wide spectrum of different hearing devices, and bone conduction implants can be found among them. Objective: The presentation of the outcomes of the implantation of a new active bone conduction hearing implant --- the Osia®, and its comparison with the well-known passive transcutaneous system --- the Baha® Attract. Materials and methods: Eight adult patients with bilateral mixed hearing loss were randomly divided into two groups. Group 1 was implanted with the Osia®, and group 2 was implanted with the Baha® Attract. The details of the surgery were analyzed, along with the functional and audiological results. Results: In all the cases, the surgery was successful, and the healing uneventful. In both groups, it was observed that pure tone audiometry and speech audiometry in free field improved significantly after the implantation (mean gain in pure tone audiometry for the Osia group 42.8 dB SPL and for the Baha group 38.8 dB SPL). In the Osia group, the results after the surgery were much better than with the Baha® 5 Power processor on the Softband. The patients implanted with the Osia® evaluated the quality of their hearing as being superior to those implanted with the Baha® Attract. There was an evident improvement in the abbreviated profile of hearing aid benefit questionnaire and in the speech, spatial and qualities of hearing scale for both systems

    Pupillometry as a Measure of Listening Effort in Patients with Bone-Anchored Hearing Systems

    No full text
    The goal of this study is to assess speech comprehension and listening effort by means of pupillometry, in patients with bone-anchored hearing system (BAHS). The study was performed prospectively in a group of 21 hearing-impaired adults, unilaterally implanted with BAHS Ponto. Listening effort was compared in patients wearing two sound processors (Oticon Medical AB, Askim, Sweden): Ponto 3 SuperPower (P3SP) and Ponto Pro (PP). Every patient was invited to two visits, separated by a 3-month break. The first session was to establish the noise level needed to obtain 95% correct sentence recall in the hearing in noise test (HINT), when speech is presented at 70 dB SPL. During the second session, pupillometry, with the use of the above-mentioned conditions, was performed. The mean HINT scores obtained during the second visit were 96.3% for PP and 97.7% for P3SP (p = 0.9863). In pupillometry, no significant differences were found for average PPD (peak pupil dilation; p = 0.3247), average peak pupil dilation timing (p = 0.527) and for pupil dilation growth curves with both processors. The findings of this study suggest that BAHS users allocate similar listening effort with PP and P3SP when processing speech-in-noise at a sound pressure level not saturating Ponto Pro and at a fixed performance level of 95%. This finding applies to the patients who meet the qualification criteria for bone conduction devices and have BC in situ threshold average below 45 dB HL

    Piezoelectric bone conduction hearing implant Osia® – audiological and quality of life benefits

    No full text
    Introduction: Nowadays, there are many options to treat hearing-impaired patients: tympanoplastic surgery, hearing aids and a wide range of implantable devices. Aim: The aim of this study is to present the mid-term audiological and quality of life benefits after the implantation of Osia®, an active piezoelectric bone conduction hearing implant. Material and methods: The state of the tissues in the implanted area, as well as audiological and quality of life results were analyzed at six, nine and twelve months after implantation in a group of four adult patients with bilateral mixed hearing loss (1 after bilateral canal-wall-down mastoidectomy, 2 with chronic simple otitis media and after myringoplasty in the opposite ear, 1 with bilateral otosclerosis and after stapedotomy in the opposite ear). Results: No postoperative complications were found in any of the cases. One year after surgery the mean audiological gain in FF PTA4 (pure tone average for 0.5, 1, 2, and 4 kHz) was 52.2 ± 3.5 dB in comparison to the unaided situation, the mean speech understanding with Osia® in quiet was 90 ± 8.2% for 50 dB SPL, 98.8 ± 2.5% for 65 dB SPL and 100 ± 0% for 80 dB SPL, and the mean speech understanding with Osia® in noise was 37.5% ± 23.6 for 50 dB SPL, 93.8 ± 4.8% for 65 dB SPL and 98.8 ± 2.5% for 80 dB SPL. There was also an evident improvement in the quality of hearing as well as in the quality of life, measured by APHAB (Abbreviated Profile of Hearing Aid Benefit) and SSQ (Speech, Spatial and Qualities of Hearing Scale). Conclusions: The Osia® is an effective treatment option for patients with bilateral mixed hearing loss. The mid-term audiological and quality of life results are excellent, but further observations including bigger groups of patients and a longer follow-up are required

    Robot-Assisted Electrode Insertion in Cochlear Implantation Controlled by Intraoperative Electrocochleography—A Pilot Study

    No full text
    Robotics in otology has been developing in many directions for more than two decades. Current clinical trials focus on more accurate stapes surgery, minimally invasive access to the cochlea and less traumatic insertion of cochlear implant (CI) electrode arrays. In this study we evaluated the use of the RobOtol® (Collin, Bagneux, France) otologic robot to insert CI electrodes into the inner ear with intraoperative ECochG analysis. This prospective, pilot study included two adult patients implanted with Advanced Bionics (Westinghouse PI, CA, USA) cochlear implant, with HiFocus™ Mid-Scala electrode array. The standard surgical approach was used. For both subjects, who had residual hearing in the implanted ear, intraoperative and postoperative ECochG was performed with the AIMTM system. The surgeries were uneventful. A credible ECochG response was obtained after complete electrode insertion in both cases. Preoperative BC thresholds compared to intraoperative estimated ECochG thresholds and 2-day postoperative BC thresholds had similar values at frequencies where all thresholds were measurable. The results of the ECochG performed one month after the surgery showed that in both patients the hearing residues were preserved for the selected frequencies. The RobOtol® surgical robot allows for the correct, safe and gentle insertion of the cochlear implant electrode inside the cochlea. The use of electrocochleography measurements during robotic cochlear implantation offers an additional opportunity to evaluate and modify the electrode array insertion on an ongoing basis, which may contribute to the preservation of residual hearing
    corecore