223 research outputs found

    Full-text publication of abstracts presented at European Orthodontic Society congresses

    Get PDF
    SUMMARYINTRODUCTION: Empirical evidence has indicated that only a subsample of studies conducted reach full-text publication and this phenomenon has become known as publication bias. A form of publication bias is the selectively delayed full publication of conference abstracts. The objective of this article was to examine the publication status of oral abstracts and poster-presentation abstracts, included in the scientific program of the 82nd and 83rd European Orthodontic Society (EOS) congresses, held in 2006 and 2007, and to identify factors associated with full-length publication. METHODS: A systematic search of PubMed and Google Scholar databases was performed in April 2013 using author names and keywords from the abstract title to locate abstract and full-article publications. Information regarding mode of presentation, type of affiliation, geographical origin, statistical results, and publication details were collected and analyzed using univariable and multivariable logistic regression. RESULTS: Approximately 51 per cent of the EOS 2006 and 55 per cent of the EOS 2007 abstracts appeared in print more than 5 years post congress. A mean period of 1.32 years elapsed between conference and publication date. Mode of presentation (oral or poster), use of statistical analysis, and research subject area were significant predictors for publication success. LIMITATIONS: Inherent discrepancies of abstract reporting, mainly related to presentation of preliminary results and incomplete description of methods, may be considered in analogous studies. CONCLUSIONS: On average 52.2 per cent of the abstracts presented at the two EOS conferences reached full publication. Abstracts presented orally, including statistical analysis, were more likely to get publishe

    Time relevance, citation of reporting guidelines, and breadth of literature search in systematic reviews in orthodontics

    Get PDF
    SummaryIntroduction: As the importance of systematic review (SR) conclusions relies upon the scientific rigor of methods and the currency of evidence, we aimed to investigate the currency of orthodontic SRs using as proxy the time from the initial search to publication. Additionally, SR information regarding reporting guidelines, registration, and literature searches were recorded when available. Materials and methods: A systematic PubMed search was carried out using the Clinical Queries page to identify orthodontic SRs cited between 1 January 2008 and 7 November 2013. Data related to reporting guidelines, review registration, dates of review processing, literature search, and abstract reporting were retrieved and classified by journal type. Survival analysis was used to assess the time to reach predefined manuscript stages for orthodontic and non-orthodontic journals. Results: One hundred twenty seven of the originally identified 585 SRs were considered eligible. The median interval from search until publication was 13.2 months (interquartile range: IQR = 9.7 months) irrespective of the journal type. There was evidence (P = 0.05) that SRs published by non-orthodontic journals appeared in PubMed faster than in orthodontic journals (non-orthodontic: median = 6.5 months; IQR = 5.7 months; orthodontic: median = 10.2 months; IQR = 5.6 months) from submission to publication and from acceptance to publication (non-orthodontic: median = 1.5 months; IQR = 2.4 months; orthodontic: median = 6.0 months; IQR = 6.2 months; P < 0.001). More than half of these SRs did not cite adherence to any reporting guidelines, whereas all but five studies were not prospectively registered. Search of unpublished research was undertaken in approximately 21 per cent and 29 per cent of the SRs published in non-orthodontic and orthodontic periodicals, respectively. Conclusions: This study indicates that SR users should be aware that median time for orthodontic SRs from search to publication is 13.2 months. SRs published in non-orthodontic journals are likely to be more current in terms of submission until time to publication and acceptance until time to publication compared with those published in orthodontic journal

    3D Method for Occlusal Tooth Wear Assessment in Presence of Substantial Changes on Other Tooth Surfaces

    Get PDF
    Early diagnosis and timely management of tooth or dental material wear is imperative to avoid extensive restorations. Previous studies suggested different methods for tooth wear assessment, but no study has developed a three‐dimensional (3D) superimposition technique applicable in cases where tooth surfaces, other than the occlusal, undergo extensive morphological changes. Here, we manually grinded plaster incisors and canines to simulate occlusal tooth wear of varying severity in teeth that received a wire retainer bonded on their lingual surfaces, during the assessment period. The corresponding dental casts were scanned using a surface scanner. The modified tooth crowns were best‐fit approximated to the original crowns using seven 3D superimposition techniques (two reference areas with varying settings) and the gold standard technique (GS: intact adjacent teeth and alveolar processes as superimposition reference), which provided the true value. Only a specific technique (complete crown with 20% estimated overlap of meshes), which is applicable in actual clinical data, showed perfect agreement with the GS technique in all cases (median difference: −0.002, max absolute difference: 0.178 mm3). The outcomes of the suggested and the GS technique were highly reproducible (max difference < 0.040 mm3). The presented technique offers low cost, convenient, accurate, and risk‐free tooth wear assessment

    Investigation of bacteremia induced by removal of orthodontic mini-implants

    Get PDF
    SUMMARY The aim of this study was to investigate potential occurrence of bacteremia in orthodontic patients after removal of miniscrews.The study group comprised 30 healthy subjects (17 males, 13 females) with a mean age of 24.1 years treated with self-ligating fixed appliances and mini-implant anchorage. Two 20ml venous blood samples were obtained prior to and 30-60 seconds after miniscrew explantation following an aseptic technique. Blood culturing in aerobic and anaerobic conditions was carried out by means of the BACTEC blood culture analyzer. Microbiological analysis showed that none of the pre- and post-operative samples exhibited detectable bacteremia. Future research should be focused on determining the collective bacteremic effect of a sequence of orthodontic procedures including miniscrew placement or removal, typically performed during a single treatment sessio

    Antimicrobial loading of nanotubular titanium surfaces favoring surface coverage by mammalian cells over bacterial colonization

    Get PDF
    Titanium is frequently used for dental implants, percutaneous pins and screws or orthopedic joint prostheses. Implant surfaces can become peri-operatively contaminated by surgically introduced bacteria during implantation causing lack of surface coverage by mammalian cells and subsequent implant failure. Especially implants that have to function in a bacteria-laden environment such as dental implants or percutaneous pins, cannot be surgically implanted while being kept sterile. Accordingly, contaminating bacteria adhering to implant surfaces hamper successful surface coverage by mammalian cells required for long-term functioning. Here, nanotubular titanium surfaces were prepared and loaded with Ag nanoparticles or gentamicin with the aim of killing contaminating bacteria in order to favor surface coverage by mammalian cells. In mono-cultures, unloaded nanotubules did not cause bacterial killing, but loading of Ag nanoparticles or gentamicin reduced the number of adhering Staphylococcus aureus or Pseudomonas aeruginosa CFUs. A gentamicin-resistant Staphylococcus epidermidis was only killed upon loading with Ag nanoparticles. However, unlike low-level gentamicin loading, loading with Ag nanoparticles also caused tissue-cell death. In bi-cultures, low-level gentamicin-loading of nanotubular titanium surfaces effectively eradicated contaminating bacteria favoring surface coverage by mammalian cells. Thus, care must be taken in loading nanotubular titanium surfaces with Ag nanoparticles, while low-level gentamicin-loaded nanotubular titanium surfaces can be used as a local antibiotic delivery system to negate failure of titanium implants due to peri-operatively introduced, contaminating bacteria without hampering surface coverage by mammalian cells

    Enamel reduction techniques in orthodontics:a literature review

    Get PDF
    Artificial abrasion of interproximal surfaces has been described for almost seventy years as orthodontic intervention for achievement and maintenance of ideal treatment outcome. A variety of terms and approaches have been introduced throughout this period implying a growing clinicians' interest. Nevertheless, the widespread recognition of enamel stripping technique was initiated by the advent of bonded orthodontic attachments and a 2-article series of Sheridan in the 80's. Since then, experimental and clinical research has been focused on the investigation of instrumentation efficacy and potential iatrogenic sequelae related to interproximal stripping. This review discusses the evolution, technical aspects and trends of enamel reduction procedures as documented in the literature

    Applications of 3D printing on craniofacial bone repair: A systematic review

    Get PDF
    Objectives Three-dimensional (3D) bioprinting, a method derived from additive manufacturing technology, is a recent and ongoing trend for the construction of 3D volumetric structures. The purpose of this systematic review is to summarize evidence from existing human and animal studies assessing the application of 3D printing on bone repair and regeneration in the craniofacial region. Data & sources A rigorous search of all relevant clinical trials and case series was performed, based on specific inclusion and exclusion criteria. The search was conducted in all available electronic databases and sources, supplemented by a manual search, in December 2017. Study selection 43 articles (6 human and 37 animal studies) fulfilled the criteria. The human studies included totally 81 patients with craniofacial bone defects. Titanium or hydroxylapatite scaffolds were most commonly implanted. The follow-up period ranged between 6 and 24 months. Bone repair was reported successful in nearly every case, with minimal complications. Also, animal intervention studies used biomaterials and cells in various combination, offering insights into the techniques, through histological, biochemical, histomorphometric and microcomputed tomographic findings. The results in both humans and animals, though promising, are yet to be verified for clinical impact. Conclusions Future research should be focused on well-designed clinical trials to confirm the short- and long- term efficacy of 3D printing strategies for craniofacial bone repair. Clinical significance Emerging 3D printing technology opens a new era for tissue engineering. Humans and animals on application of 3D printing for craniofacial bone repair showed promising results which will lead clinicians to investigate more thoroughly alternative therapeutic methods for craniofacial bone defects

    Precision of a Hand-Held 3D Surface Scanner in Dry and Wet Skeletal Surfaces: An Ex Vivo Study

    Get PDF
    Three-dimensional surface scans of skeletal structures have various clinical and research applications in medicine, anthropology, and other relevant fields. The aim of this study was to test the precision of a widely used hand-held surface scanner and the associated software’s 3D model generation-error in both dry and wet skeletal surfaces. Ten human dry skulls and ten mandibles (dry and wet conditions) were scanned twice with an industrial scanner (Artec Space Spider) by one operator. Following a best-fit superimposition of corresponding surface model pairs, the mean absolute distance (MAD) between them was calculated on ten anatomical regions on the skulls and six on the mandibles. The software’s 3D model generation process was repeated for the same scan of four dry skulls and four mandibles (wet and dry conditions), and the results were compared in a similar manner. The median scanner precision was 31 ÎŒm for the skulls and 25 ÎŒm for the mandibles in dry conditions, whereas in wet conditions it was slightly lower at 40 ÎŒm for the mandibles. The 3D model generation-error was negligible (range: 5–10 ÎŒm). The Artec Space Spider scanner exhibits very high precision in the scanning of dry and wet skeletal surfaces

    Time relevance, citation of reporting guidelines, and breadth of literature search in systematic reviews in orthodontics

    Get PDF
    INTRODUCTION As the importance of systematic review (SR) conclusions relies upon the scientific rigor of methods and the currency of evidence, we aimed to investigate the currency of orthodontic SRs using as proxy the time from the initial search to publication. Additionally, SR information regarding reporting guidelines, registration, and literature searches were recorded when available. MATERIALS AND METHODS A systematic PubMed search was carried out using the Clinical Queries page to identify orthodontic SRs cited between 1 January 2008 and 7 November 2013. Data related to reporting guidelines, review registration, dates of review processing, literature search, and abstract reporting were retrieved and classified by journal type. Survival analysis was used to assess the time to reach predefined manuscript stages for orthodontic and non-orthodontic journals. RESULTS One hundred twenty seven of the originally identified 585 SRs were considered eligible. The median interval from search until publication was 13.2 months (interquartile range: IQR = 9.7 months) irrespective of the journal type. There was evidence (P = 0.05) that SRs published by non-orthodontic journals appeared in PubMed faster than in orthodontic journals (non-orthodontic: median = 6.5 months; IQR = 5.7 months; orthodontic: median = 10.2 months; IQR = 5.6 months) from submission to publication and from acceptance to publication (non-orthodontic: median = 1.5 months; IQR = 2.4 months; orthodontic: median = 6.0 months; IQR = 6.2 months; P < 0.001). More than half of these SRs did not cite adherence to any reporting guidelines, whereas all but five studies were not prospectively registered. Search of unpublished research was undertaken in approximately 21 per cent and 29 per cent of the SRs published in non-orthodontic and orthodontic periodicals, respectively. CONCLUSIONS This study indicates that SR users should be aware that median time for orthodontic SRs from search to publication is 13.2 months. SRs published in non-orthodontic journals are likely to be more current in terms of submission until time to publication and acceptance until time to publication compared with those published in orthodontic journals

    Streptococcus mutans adhesion force sensing in multi-species oral biofilms

    Get PDF
    Bacteria utilize chemical and mechanical mechanisms to sense their environment, to survive hostile conditions. In mechanical sensing, intra-bilayer pressure profiles change due to deformation induced by the adhesion forces bacteria experience on a surface. Emergent properties in mono-species Streptococcus mutans biofilms, such as extracellular matrix production, depend on the adhesion forces that streptococci sense. Here we determined whether and how salivary-conditioning film (SCF) adsorption and the multi-species nature of oral biofilm influence adhesion force sensing and associated gene expression by S. mutans. Hereto, Streptococcus oralis, Actinomyces naeslundii, and S. mutans were grown together on different surfaces in the absence and presence of an adsorbed SCF. Atomic force microscopy and RT-qPCR were used to measure S. mutans adhesion forces and gene expressions. Upon SCF adsorption, stationary adhesion forces decreased on a hydrophobic and increased on a hydrophilic surface to around 8 nN. Optical coherence tomography showed that triple-species biofilms on SCF-coated surfaces with dead S. oralis adhered weakly and often detached as a contiguous sheet. Concurrently, S. mutans displayed no differential adhesion force sensing on SCF-coated surfaces in the triple-species biofilms with dead S. oralis, but once live S. oralis were present S. mutans adhesion force sensing and gene expression ranked similar as on surfaces in the absence of an adsorbed SCF. Concluding, live S. oralis may enzymatically degrade SCF components to facilitate direct contact of biofilm inhabitants with surfaces and allow S. mutans adhesion force sensing of underlying surfaces to define its appropriate adaptive response. This represents a new function of initial colonizers in multi-species oral biofilms
    • 

    corecore