17 research outputs found

    Age-related changes in global motion coherence: conflicting haemodynamic and perceptual responses

    Get PDF
    Our aim was to use both behavioural and neuroimaging data to identify indicators of perceptual decline in motion processing. We employed a global motion coherence task and functional Near Infrared Spectroscopy (fNIRS). Healthy adults (n = 72, 18-85) were recruited into the following groups: young (n = 28, mean age = 28), middle-aged (n = 22, mean age = 50), and older adults (n = 23, mean age = 70). Participants were assessed on their motion coherence thresholds at 3 different speeds using a psychophysical design. As expected, we report age group differences in motion processing as demonstrated by higher motion coherence thresholds in older adults. Crucially, we add correlational data showing that global motion perception declines linearly as a function of age. The associated fNIRS recordings provide a clear physiological correlate of global motion perception. The crux of this study lies in the robust linear correlation between age and haemodynamic response for both measures of oxygenation. We hypothesise that there is an increase in neural recruitment, necessitating an increase in metabolic need and blood flow, which presents as a higher oxygenated haemoglobin response. We report age-related changes in motion perception with poorer behavioural performance (high motion coherence thresholds) associated with an increased haemodynamic response

    Resonance frequency analysis with two different devices after conventional implant placement with ridge preservation:A prospective pilot cohort study

    No full text
    Background Primary and secondary implant stability is of high importance for survival and success of dental implants in the short and long term. Measurements of implant stability during healing provide the opportunity to monitor the course of the osseointegration process. Purpose To compare implant stability quotient (ISQ) by resonance frequency analysis (RFA), recorded with two different devices after implant placement. Materials and methods Patients with the need of single tooth extraction in posterior sites of the maxilla and the mandible were treated in a surgical center. All patients received additional augmentation with a bovine bone substitute and platelet-rich fibrin (PRF) after atraumatic tooth extraction. After a healing period of 10 weeks, 28 self-tapping titanium-implants were placed. Implant stability was recorded with two different devices (Osstell and Penguin) at the time of implant insertion (T0), 10 days later (T1), and after 7 (T2), or 17 weeks (T3). Results No implant was lost, and no postoperative complication occurred during follow-up. Patient cohort comprised 9 female (32.1%) and 19 male patients (67.9%), with a mean age of 52.8 years, 64.3 years, respectively. Mean overall insertion torque was 43.6 Ncm at implant placement with no significant difference between implant location, age, or gender. No patient dropped out. During observation period, a significant increase in mean ISQ was recorded with both devices. Significant positive correlations between insertion torque and ISQ were recorded with both devices at T0, T2, and T3. No significant differences were observed in ISQ-values between both devices, and measuring directions at any point of measurement. Conclusions Within the limitations of this cohort study, both devices were suitable for RFA-measurement and revealed comparable results. Due to the cordless design, handling of the Penquin device was more comfortable. Reusability of the Penguin MultiPeg-transducers may offer an additional benefit with regard on ecological aspects

    Impaired platelet adhesion to lysed fibrin, whereas neutrophil adhesion remains intact under conditions of flow

    No full text
    Vessel wall injury induces the formation of a haemostatic plug. Restoration of vascular integrity should involve cessation of further platelet and fibrin deposition and subsequent removal of these thrombi by both the fibrinolytic system and proteases delivered by infiltrating inflammatory cells. We hypothesized that adhesion of platelets and inflammatory cells [polymorphonuclear leucocyte (PMN)] to fibrin is differently supported after exposure of fibrin during fibrinolysis. Fibrin surfaces were exposed to fibrinolytic agents, and platelet and PMN adhesion was studied under conditions of flow. Specific adhesion of platelets to preformed fibrin was reduced by fibrinolytic treatment of the fibrin. PMN adhesion to fibrin was only slightly affected even after 180 min exposure to plasmin. With fibrin still present after fibrinolytic treatment, the impaired platelet adhesion seems explained by loss of the primary platelet adhesion site gamma400-411 on fibrin. PMN binding to fibrin clearly depends on other sites that are less degraded by fibrinolysis. We have shown that PMN adhesion in flowing blood to lysed fibrin was still present, whereas platelet adhesion was impaired due to the loss of the primary platelet adhesion site gamma400-411. Based on our in-vitro perfusion model, we conclude that fibrinolysis specifically interferes with the thrombogenicity of fibrin in the haemostatic plug, whereas the inflammatory response is preserved. The latter may participate in the long-term removal and restructuration of the plu

    Hypobaric Hypoxia Causes Elevated Thrombin Generation Mediated by FVIII that is Balanced by Decreased Platelet Activation

    No full text
    Introduction Epidemiological studies suggest that hypobaric hypoxia at high altitude poses a risk for developing venous thromboembolism. The cause of this observed hypercoagulability remains unclear. Therefore, this study aimed to investigate the effect of hypobaric hypoxia at 3,883 m above sea level on thrombin generation and platelet activation. Methods After complying with medical ethical procedures, 18 participants were recruited, of whom 1 had to leave the study prematurely due to mild acute mountain sickness. Blood was drawn first at 50 m above sea level and second at 3,883 m altitude after gradual acclimatization for 6 days. Thrombin generation was measured in whole blood, platelet-rich plasma and platelet-poor plasma. Platelet activation was assessed using a whole blood flow-cytometric assay. Coagulation factor levels, D-dimer levels and markers of dehydration and inflammation were measured. Results Hypobaric hypoxia at 3,883 m altitude caused increased thrombin generation, measured as peak height and endogenous thrombin potential, in whole blood, platelet-rich and platelet-poor plasma without or at low tissue factor concentration. The elevated thrombin generation was mediated by increased factor VIII levels and not caused by dehydration or inflammation. In contrast, spontaneous and agonist-induced platelet activation was decreased at high altitude. Conclusion Hypobaric hypoxia causes increased factor VIII-mediated thrombin generation. The hypercoagulability was balanced by decreased platelet activation. These findings may explain why venous, and not arterial thrombotic events occur more frequently at high altitude

    Patients With Multiple Myeloma Have a Disbalanced Whole Blood Thrombin Generation Profile

    No full text
    BACKGROUND: Multiple myeloma (MM) is associated with a high prevalence of bleeding and an increased risk of thrombo-embolism. MM patients have reduced platelet- and red blood cell (RBC) numbers in blood, which may indicate that the paradoxical hemostasis profile is a consequence of a disturbed platelet and RBC homeostasis. OBJECTIVES: To get better insight in the disbalanced hemostasis of MM patients. METHODS: We conducted a case-control study on the whole blood (WB) coagulation profiles of 21 MM patients and 21 controls. We measured thrombin generation (TG) in WB and platelet poor plasma (PPP) of MM patients and controls. RESULTS: In WB-TG, we observed that the median time to the thrombin Peak was 52% longer in MM patients than in controls, while the median endogenous thrombin potential until the Peak (ETPp) was 39% higher in MM-patients than in controls. In line with these findings, the levels of platelets, RBCs, white blood cells and agonist induced platelet activation were decreased in MM patients compared to controls. The plasma TG experiments showed no differences between MM-patients and controls. CONCLUSION: Patients with MM have a disturbed blood cell metabolism and a disbalanced WB-TG profile. This disbalance may explain the paradoxically high prevalence of bleeding symptoms in MM patients vs. an increased thrombosis risk. There was no disturbance observed in plasma TG, indicating that blood cells are the major determinants for the disbalanced hemostasis in MM patients

    Analytical characterization and reference interval of an enzyme-linked immunosorbent assay for active von Willebrand factor.

    No full text
    BackgroundInteraction of von Willebrand factor (VWF) with platelets requires a conformational change that exposes an epitope within the VWF A1 domain, enabling platelet glycoprotein Ibα binding. Quantification of this ''active" conformation of VWF has been shown to provide pathophysiological insight into conditions characterized by excessive VWF-platelet interaction.MethodsWe developed an immunosorbent assay based on a variable heavy chain antibody fragment against the VWF A1 domain as a capture antibody. Assay performance in terms of specificity (binding to active R1306W- and sheared VWF), precision, accuracy, linearity, limits of detection and stability were determined. Active VWF, VWF antigen, VWF ristocetin cofactor activity, VWF:GP1bM and VWF propeptide were measured in citrated plasma and platelet-VWF binding in whole blood from 120 healthy individuals to establish a reference interval for active VWF and to assess associations with other VWF parameters.ResultsIntra- and inter-assay CVs were between 2.4-7.2% and 4.1-9.4%, depending on the level. Mean recovery of spiked recombinant R1306W VWF was 103±3%. The assay was linear in the range of 90.1-424.5% and had a limit of quantification of 101%. The reference interval for active VWF was 91.6-154.8% of NPP. Significant, positive correlations between active VWF and all other VWF parameters were found, with the strongest correlation with VWF:GP1bM binding.ConclusionsWe developed and validated an immunosorbent assay for the accurate detection of active VWF levels in plasma. The assay fulfilled all analytical criteria in this study and a reference interval was established, allowing its use to quantify active VWF in pathological conditions for future research
    corecore