27 research outputs found

    One-year follow-up after active aortic aneurysm sac treatment with shape memory polymer devices during endovascular aneurysm repair

    Get PDF
    Objective: To determine the safety and efficacy of treating abdominal aortic aneurysm (AAA) sacs with polyurethane shape memory polymer (SMP) devices during endovascular aneurysm repair (EVAR), using a technique to fully treat the target lumen after endograft placement (aortic flow volume minus the endograft volume). SMP devices self-expand in the sac to form a porous scaffold that supports thrombosis throughout its structure. Methods: Two identical prospective, multicenter, single-arm studies were conducted in New Zealand and the Netherlands. The study population was adult candidates for elective EVAR of an infrarenal AAA (diameter of ≥55 mm in men and ≥50 mm in women). Key exclusion criteria were an inability to adequately seal a common iliac artery aneurysm, patent sac feeding vessels of &gt;4 mm, and a target lumen volume of &lt;20 mL or &gt;135 mL. Target lumen volumes were estimated by subtracting endograft volumes from preprocedural imaging-based flow lumen volumes. SMP devices were delivered immediately after endograft deployment via a 6F sheath jailed in a bowed position in the sac. The primary efficacy end point was technical success, defined as filling the actual target lumen volume with fully expanded SMP at the completion of the procedure. Secondary efficacy outcome measures during follow-up were the change in sac volume and diameter, rate of type II endoleak and type I or III endoleaks, and the rate of open repair and related reinterventions, with data collection at 30 days, 6 months, and 1 year (to date). Baseline sac volumes and diameters for change in sac size analyses were determined from 30-day imaging studies. Baseline and follow-up volumes were normalized by subtraction of the endograft volume. Results: Of 34 patients treated with SMP devices and followed per protocol, 33 patients were evaluable at 1 year. Preprocedural aneurysm volume was 181.4 mL (95% confidence interval [CI], 150.7-212.1 mL) and preprocedural aneurysm diameter was 60.8 mm (95% CI, 57.8-63.9 mm). The target lumen volume was 56.3 mL (95% CI, 46.9-65.8 mL). Technical success was 100% and the ratio of SMP fully expanded volume to estimated target lumen volume was 1.4 ± 0.3. Baseline normalized sac volume and diameter were 140.7 mL (95% CI, 126.6-154.9 mL) and 61.0 mm (95% CI, 59.7-62.3 mm). The adjusted mean percentage change in normalized volume at 1 year was −28.8% (95% CI, −35.3 to −22.3%; P &lt; .001). The adjusted mean change in sac diameter at 1 year was −5.9 mm (95% CI, −7.5 to −4.4 mm; P &lt; .001). At 1 year, 81.8% of patients (95% CI, 64.5%-93.0%) achieved a ≥10% decrease in normalized volume and 57.6% of patients (95% CI, 39.2%-74.5%) achieved a ≥5 mm decrease in diameter. No device- or study procedure-related major adverse events occurred through 1 year after the procedure. Conclusions: Treatment of AAA sacs with SMP devices during EVAR resulted in significant sac volume and diameter regression at 1 year with an acceptable safety profile in this prospective study.</p

    Geometric Analysis of the Gore Excluder Conformable Endoprosthesis in the Infrarenal Aortic Neck: One Year Results of the EXCeL Registry

    Get PDF
    Objective: The Gore Excluder Conformable Endoprosthesis (CEXC) is designed to treat challenging infrarenal anatomy because of its active angulation control, repositionability, and enhanced conformability. This study evaluated 30 day and one year position and apposition of the CEXC in the infrarenal neck. Methods: Patients treated with the CEXC between 2018 and 2022 with an available 30 day computed tomography angiogram (CTA) were selected from four hospitals in a prospective registry. Endograft apposition (shortest apposition length [SAL]) and position (shortest fabric distance [SFD]) were assessed on the 30 day and one year CTAs. Maximum infrarenal aortic curvature was compared between the pre- and post-operative CTAs to evaluate conformability of the CEXC. Results: There were 87 patients with a 30 day CTA, and for 56 of these patients the one year CTA was available. Median (interquartile range [IQR]) pre-operative neck length was 22 mm (IQR 15, 32) and infrarenal angulation was 52° (IQR 31, 72). Median SAL was 21.2 mm (IQR 14.0, 29.3) at 30 days for all included patients. The SAL in 13 patients (15%) was &lt; 10 mm at 30 days, and one patient had a SAL of 0 mm and a type Ia endoleak. There was no significant difference in SAL between patients within and outside instructions for use. The SAL significantly increased by 1.1 mm (IQR −2.3, 4.7; p =.042) at one year. The SAL decreased in seven patients (13%), increased in 13 patients (23%), and remained stable in 36 patients (64%). Median SFD was 2.0 mm (IQR 0.5, 3.6) at 30 days, which slightly increased by 0.3 mm (IQR −0.5, 1.8; p =.019) at one year. One patient showed migration (SFD increase ≥ 5 mm). Median endograft tilt was 15.8° (IQR 9.7, 21.4). Pre-operative maximum infrarenal curvature was 36 m −1 (IQR 26, 56) and did not significantly change thereafter. Conclusion: In most patients, the CEXC was implanted close to the renal arteries, and sufficient (≥ 10 mm) post-operative apposition was achieved at 30 days, which slightly increased at one year. Post-operative endograft tilt was relatively low, and aortic geometry remained unchanged after implantation of the CEXC, probably due to its high conformability.</p

    Lipids and theirs carriers in sportsmen : the lipoprotein particles

    No full text
    BACKGROUND: Hidradenitis suppurativa (HS) is an inflammatory follicular skin disease. In women and men, the condition starts after puberty, has a peak in the third decade, and is rare after the menopause in women. This age distribution suggests a hormonal influence in the pathogenesis of the disease. We therefore hypothesized that apocrine glands in HS patients have a different expression of androgen receptor (AR) and estrogen receptor (ER) compared with healthy skin. METHODS: Axillary, inguinal, and perianal skin biopsies from female and male patients with HS were immunohistochemically stained for AR and ER activities. Expression of both receptors in apocrine glands of HS patients was compared with expression in apocrine glands in normal axillary or inguinal skin of a control group of women. RESULTS: Twenty-two patients with HS were included (16 women), with 10 women in the control group. In the HS group, apocrine glands were present in 11 out of 22 skin biopsies and in the control group in 4 out of 10 biopsies. Expression of ER in the apocrine gland was weak and observed in 2 out of 4 patients in the control group and in none of the HS patients. Expression of the AR was strong and observed in all apocrine glands in both groups. CONCLUSIONS: We could not demonstrate a significant difference in the expression of ER and AR in apocrine glands in skin biopsies of patients with HS, compared with healthy skin biopsies. The exact relation between sex hormones and occurrence of HS therefore remains unclear

    Endovascular Treatment of Occlusive Lesions in the Aortic Bifurcation with Kissing Polytetrafluoroethylene-Covered Stents

    No full text
    Item does not contain fulltextPURPOSE: To determine the clinical outcomes of polytetrafluoroethylene covered balloon expandable stents (CBESs) in occlusive lesions of the aortic bifurcation in a kissing stent configuration. MATERIALS AND METHODS: The study included 69 consecutive patients (29 men, 40 women) who underwent kissing stent procedures with CBESs between January 2003 and April 2009 in a single center. Patients who were previously treated with a CBES were excluded. Follow-up consisted of clinical investigation and duplex ultrasound examination. RESULTS: The primary patency was 88.1% at 1 year and 71.5% at 4 years, with secondary patency rates of 88.1% and 75.3%, respectively. For patients receiving a stent for the first time, primary patency was 91.3% at 1 year and 77.1% at 4 years. For patients who had received previous stents, patency was 83.6% at 1 year and 65.2% at 4 years (P = .83). There were no differences in secondary patency and freedom from target lesion reintervention (TLR). Loss of primary patency was mainly caused by stent occlusions (14 cases [78%]). The freedom from TLR at 4 years was 76.8%. CONCLUSIONS: Patency rates and freedom from TLR of CBESs in the kissing stent configuration with up to 4 years of follow-up were satisfying and mainly affected by stent occlusions. Studies focusing on optimizing stent configuration and medical care to reduce the incidence of thrombosis are indicated to improve results further

    A systematic review summarizing local vascular characteristics of aneurysm wall to predict for progression and rupture risk of abdominal aortic aneurysms.

    No full text
    OBJECTIVE: At present, the rupture risk prediction of abdominal aortic aneurysms (AAAs) and, hence, the clinical decision making regarding the need for surgery, is determined by the AAA diameter and growth rate. However, these measures provide limited predictive information. In the present study, we have summarized the measures of local vascular characteristics of the aneurysm wall that, independently of AAA size, could predict for AAA progression and rupture. METHODS: We systematically searched PubMed and Web of Science up to September 13, 2021 to identify relevant studies investigating the relationship between local vascular characteristics of the aneurysm wall and AAA growth or rupture in humans. A quality assessment was performed using the ROBINS-I (risk of bias in nonrandomized studies of interventions) tool. All included studies were divided by four types of measures of arterial wall characteristics: metabolism, calcification, intraluminal thrombus, and compliance. RESULTS: A total of 20 studies were included. Metabolism of the aneurysm wall, especially when measured by ultra-small superparamagnetic iron oxide uptake, and calcification were significantly related to AAA growth. A higher intraluminal thrombus volume and thickness had correlated positively with the AAA growth in one study but in another study had correlated negatively. AAA compliance demonstrated no correlation with AAA growth and rupture. The aneurysmal wall characteristics showed no association with AAA rupture. However, the metabolism, measured via ultra-small superparamagnetic iron oxide uptake, but none of the other measures, showed a trend toward a relationship with AAA rupture, although the difference was not statistically significant. CONCLUSIONS: The current measures of aortic wall characteristics have the potential to predict for AAA growth, especially the measures of metabolism and calcification. Evidence regarding AAA rupture is scarce, and, although more work is needed, aortic wall metabolism could potentially be related to AAA rupture. This highlights the role of aortic wall characteristics in the progression of AAA but also has the potential to improve the prediction of AAA growth and rupture
    corecore