4 research outputs found

    Effect of internal port on dose distribution in post-mastectomy radiotherapy for breast cancer patients after expander breast reconstruction

    Get PDF
    Background: In patients with expander-based reconstruction a few dosimetric analyses detected radiation therapy dose perturbation due to the internal port of an expander, potentially leading to toxicity or loss of local control. This study aimed at adding data on this field. Materials and methods: A dosimetric analysis was conducted in 30 chest wall treatment planning without and with correction for port artifact. In plans with artifact correction density was overwritten as 1 g/cm3. Medium, minimum and maximum chest wall doses were compared in the two plans. Both plans, with and without correction, were compared on an anthropomorphic phantom with a tissue expander on the chest covered by a bolus simulating the skin. Ex vivo dosimetry was carried out on the phantom and in vivo dosimetry in three patients by using film strips during one treatment fraction. Estimated doses and measured film doses were compared. Results: No significant differences emerged in the minimum, medium and maximum doses in the two plans, without and with correction for port artifacts. Ex vivo and in vivo analyses showed a good correspondence between detected and calculated doses without and with correction. Conclusions: The port did not significantly affect dose distribution in patients who will receive post-mastectomy radiation therapy (PMRT)

    Characterization of a silicon strip detector and a YAG:Ce calorimeter for a proton computed radiography apparatus

    Get PDF
    Today, there is a steadily growing interest in the use of proton beams for tumor therapy, as they permit to tightly shape the dose delivered to the target reducing the exposure of the surrounding healthy tissues. Nonetheless, accuracy in the determination of the dose distribution in proton-therapy is up to now limited by the uncertainty in stopping powers, which are presently calculated from the photon attenuation coefficients measured by X-ray tomography. Proton computed tomography apparatus (pCT) has been proposed to directly measure the stopping power and reduce this uncertainty. Main problem with proton imaging is the blurring effect introduced by multiple Coulomb scattering: single proton tracking is a promising technique to face this difficulty. As a first step towards a pCT system, we designed a proton radiography (pCR) prototype based on a silicon microstrip tracker (to characterize particle trajectories) and a segmented YAG:Ce calorimeter (to measure their residual energy). Aim of the system is to detect protons with a ~1 MHz particle rate of and with kinetic energy in the range 250-270 MeV, high enough to pass through human body. Design and development of the pCR prototype, as well as the characterization of its single components, are described in this paper

    Proton radiography for clinical applications

    No full text
    Proton imaging is not yet applied as a clinical routine, although its advantages have been demonstrated. In the context of quality assurance in proton therapy, proton images can be used to verify the correct positioning of the patient and to control the range of protons. Proton computed tomography (pCT) is a 3D imaging method appropriate for planning and verification of proton radiation treatments, because it allows evaluating the distributions of proton stopping power within the tissues and can be directly utilized when the patient is in the actual treatment position. The aim of the PRoton IMAging experiment, supported by INFN, and the PRIN 2006 project, supported by MIUR, is to realize a proton computed radiography (pCR) prototype for reconstruction of proton images from a single projection in order to validate the technique with pre-clinical studies and, eventually, to conceive the configuration of a complete pCT system. A preliminary experiment performed at the 250 MeV proton synchrotron of Loma Linda University Medical Center (LLUMC) allowed acquisition of experimental data before the completion of PRIMA project's prototype. In this paper, the results of the LLUMC experiment are reported and the reconstruction of proton images of two phantoms is discussed
    corecore