    Dosimetric feasibility of utilizing the ViewRay magnetic resonance guided linac system for image-guided spine stereotactic body radiation therapy

    Get PDF
    INTRODUCTION: Spine stereotactic body radiation therapy (SBRT) achieves favorable outcomes compared to conventional radiotherapy doses/fractionation. The spinal cord is the principal dose-limiting organ-at-risk (OAR), and safe treatment requires precise immobilization/localization. Therefore, image guidance is paramount to successful spine SBRT. Conventional X-ray imaging and alignment to surrogate bony anatomy may be inadequate, whereas magnetic resonance imaging (MRI) directly visualizes the dose-limiting cord. This work assessed the dosimetric capability of the ViewRay (ViewRay Inc. Oakwood Village, OH) magnetic resonance (MR) guided linac (MR-Linac) for spine SBRT. METHODS: Eight spine SBRT patients without orthopedic hardware who were previously treated on a TrueBeam using volumetric modulated arc therapy (VMAT) were re-planned using MR-Linac fixed-field intensity-modulated radiation therapy (IMRT). Phantom measurements using film, ionization chamber, and a commercial diode-array assessed feasibility. Plans included a variety of prescriptions (30-50 Gy in 3-10 fractions). RESULTS: MR-Linac plans satisfied all clinical goals. Compared to VMAT plans, both entrance dose and heterogeneity increased (D CONCLUSION: Spine SBRT with the MR-Linac is feasible as verified via re-planning eight clinical cases followed by delivery verification in phantoms using film, diodes, and an ionization chamber. Real-time visualization of the dose-limiting cord during spine SBRT may enable cord-based gating, reduced margins, alternate dose schemas, and/or adaptive therapy

    A Doubly Constrained TV Algorithm for Image Reconstruction

    No full text
    Purpose. The total variation (TV) minimization algorithm is an effective image reconstruction algorithm capable of accurately reconstructing images from sparse and/or noisy data. The TV model consists of two terms: a data fidelity term and a TV regularization term. Two constrained TV models, data divergence-constrained TV minimization (DDcTV) and TV-constrained data divergence minimization (TVcDM), have been successfully applied to computed tomography (CT) and electron paramagnetic resonance imaging (EPRI). In this work, we propose a new constrained TV model, a doubly constrained TV (dcTV) model, which has the potential to further improve the reconstruction accuracy for the two terms which are both of constraint forms. Methods. We perform an inverse crime study to validate the model and its Chambolle-Pock (CP) solver and characterize the performance of the dcTV-CP algorithm in the context of CT. To demonstrate the superiority of the dcTV model, we compare the convergence rate and the reconstruction accuracy with the DDcTV and TVcDM models via simulated data. Results and Conclusions. The performance-characterizing study shows that the dcTV-CP algorithm is an accurate and convergent algorithm, with the model parameters impacting the reconstruction accuracy and the algorithm parameters impacting the convergence path and rate. The comparison studies show that the dcTV-CP algorithm has a relatively fast convergence rate and can achieve higher reconstruction accuracy from sparse projections or noisy projections relative to the other two single-constrained TV models. The knowledge and insights gained in the work may be utilized in the application of the new model in other imaging modalities including divergence-beam CT, magnetic resonance imaging (MRI), positron emission tomography (PET), and EPRI

    Delivery of Online Adaptive MRI-Guided Radiation Therapy for a Deaf Patient.

    No full text
    MRI-guided radiation therapy (MRgRT) enables real-time imaging during treatment and daily online adaptive planning. It is particularly useful for areas of treatment that have been previously excluded or restricted from ablative doses due to potential damage to adjacent normal tissue. In certain cases, ablative doses to metastatic lesions may be justified and treated with MRgRT using video-assisted gated breath-hold adjustments throughout delivery. The workflow relies on patient biofeedback and auditory cues. A 74-year-old deaf male with a history of prostate cancer status post prostatectomy was found to have an enlarged cervical lymph node, which was excised with histopathology demonstrating Merkel cell carcinoma. Approximately one year after treatment with two cycles of pembrolizumab, which was subsequently discontinued due to toxicity, surveillance imaging demonstrated an enlarging left adrenal nodule. It was initially stable for an additional seven months with pembrolizumab rechallenge but was again found enlarged on subsequent imaging. The patient underwent MRg stereotactic body radiation therapy (MRgSBRT) to a total dose of 60 Gy in five fractions to this isolated site of progression. The patient was equipped with mirrored glasses to view the tracking structure with respect to gating the boundary structure, and the traditional reliance on verbal cues for coaching was reimagined to rely on visual cues instead. Follow-up positron emission tomography/CT (PET/CT) two weeks after treatment demonstrated interval resolution of the left adrenal metastatic nodule and a return to symmetric bilateral adrenal gland metabolic activity. The necessary MRgSBRT treatment for single metastatic lesions near normal tissue structures relies on verbal cues and coaching. However, deaf patients are unable to receive this treatment according to the traditional workflow model. Unique opportunities exist for the implementation of culturally competent care for the Deaf community, relying more heavily on visual cues, in radiation oncology practice

    Robustness Assessment of Images From a 0.35T Scanner of an Integrated MRI-Linac : Characterization of Radiomics Features in Phantom and Patient Data

    No full text
    Purpose: Radiomics entails the extraction of quantitative imaging biomarkers (or radiomics features) hypothesized to provide additional pathophysiological and/or clinical information compared to qualitative visual observation and interpretation. This retrospective study explores the variability of radiomics features extracted from images acquired with the 0.35 T scanner of an integrated MRI-Linac. We hypothesized we would be able to identify features with high repeatability and reproducibility over various imaging conditions using phantom and patient imaging studies. We also compared findings from the literature relevant to our results. Methods: Eleven scans of a Magphan® RT phantom over 13 months and 11 scans of a ViewRay Daily QA phantom over 11 days constituted the phantom data. Patient datasets included 50 images from ten anonymized stereotactic body radiation therapy (SBRT) pancreatic cancer patients (50 Gy in 5 fractions). A True Fast Imaging with Steady-State Free Precession (TRUFI) pulse sequence was selected, using a voxel resolution of 1.5 mm × 1.5 mm × 1.5 mm and 1.5 mm × 1.5 mm × 3.0 mm for phantom and patient data, respectively. A total of 1087 shape-based, first, second, and higher order features were extracted followed by robustness analysis. Robustness was assessed with the Coefficient of Variation (CoV < 5%). Results: We identified 130 robust features across the datasets. Robust features were found within each category, except for 2 second-order sub-groups, namely, Gray Level Size Zone Matrix (GLSZM) and Neighborhood Gray Tone Difference Matrix (NGTDM). Additionally, several robust features agreed with findings from other stability assessments or predictive performance studies in the literature. Conclusion: We verified the stability of the 0.35 T scanner of an integrated MRI-Linac for longitudinal radiomics phantom studies and identified robust features over various imaging conditions. We conclude that phantom measurements can be used to identify robust radiomics features. More stability assessment research is warranted

    Stereotactic Magnetic Resonance-Guided Adaptive and Non-Adaptive Radiotherapy on Combination MR-Linear Accelerators: Current Practice and Future Directions

    No full text
    Stereotactic body radiotherapy (SBRT) is an effective radiation therapy technique that has allowed for shorter treatment courses, as compared to conventionally dosed radiation therapy. As its name implies, SBRT relies on daily image guidance to ensure that each fraction targets a tumor, instead of healthy tissue. Magnetic resonance imaging (MRI) offers improved soft-tissue visualization, allowing for better tumor and normal tissue delineation. MR-guided RT (MRgRT) has traditionally been defined by the use of offline MRI to aid in defining the RT volumes during the initial planning stages in order to ensure accurate tumor targeting while sparing critical normal tissues. However, the ViewRay MRIdian and Elekta Unity have improved upon and revolutionized the MRgRT by creating a combined MRI and linear accelerator (MRL), allowing MRgRT to incorporate online MRI in RT. MRL-based MR-guided SBRT (MRgSBRT) represents a novel solution to deliver higher doses to larger volumes of gross disease, regardless of the proximity of at-risk organs due to the (1) superior soft-tissue visualization for patient positioning, (2) real-time continuous intrafraction assessment of internal structures, and (3) daily online adaptive replanning. Stereotactic MR-guided adaptive radiation therapy (SMART) has enabled the safe delivery of ablative doses to tumors adjacent to radiosensitive tissues throughout the body. Although it is still a relatively new RT technique, SMART has demonstrated significant opportunities to improve disease control and reduce toxicity. In this review, we included the current clinical applications and the active prospective trials related to SMART. We highlighted the most impactful clinical studies at various tumor sites. In addition, we explored how MRL-based multiparametric MRI could potentially synergize with SMART to significantly change the current treatment paradigm and to improve personalized cancer care