17 research outputs found
Challenges for dark matter direct search with SiPMs
Liquid xenon and liquid argon detectors are leading the direct dark matter
search and are expected to be the candidate technology for the forthcoming
generation of ultra-sensitive large-mass detectors. At present, the
scintillation light detection in those experiments is based on ultra-pure
low-noise photo-multipliers. To overcome the issues in terms of the extreme
radio-purity, costs, and technological feasibility of the future dark matter
experiments, the novel SiPM-based photo-detector modules look promising
candidates, capable of replacing the present light detection technology.
However, the intrinsic features of SiPMs may limit the present expectations. In
particular, interfering phenomena, especially related to the optical correlated
noise, can degrade the energy and pulse shape resolutions. As a consequence,
the projected sensitivity of the future detectors has to be reconsidered
accordingly.Comment: 10 pages, 8 figure
Challenges for dark matter direct search with SiPMs
Liquid xenon and liquid argon detectors are leading the direct dark matter search and are expected to be the candidate technology for the forthcoming generation of ultra-sensitive large-mass detectors. At present, scintillation light detection in those experiments is based on ultra-pure low-noise photo-multipliers. To overcome the issues in terms of the extreme radio-purity, costs, and technological feasibility of the future dark matter experiments, the novel silicon photomultiplier (SiPM)-based photodetector modules seem to be promising candidates, capable of replacing the present light detection technology. However, the intrinsic features of SiPMs may limit the present expectations. In particular, interfering phenomena, especially related to the optical correlated noise, can degrade the energy and pulse shape resolutions. As a consequence, the projected sensitivity of the future detectors has to be reconsidered accordingly
Cryogenic Characterization of FBK HD Near-UV Sensitive SiPMs
We report on the characterization of near-ultraviolet high density silicon
photomultiplier (\SiPM) developed at Fondazione Bruno Kessler (\FBK) at
cryogenic temperature. A dedicated setup was built to measure the primary dark
noise and correlated noise of the \SiPMs\ between 40 and 300~K. Moreover, an
analysis program and data acquisition system were developed to allow the
precise characterization of these parameters, some of which can vary up to 7
orders of magnitude between room temperature and 40~K. We demonstrate that it
is possible to operate the \FBK\ near-ultraviolet high density \SiPMs\ at
temperatures lower than 100~K with a dark rate below 0.01 cps/mm and total
correlated noise probability below 35\% at an over-voltage of 6~V. These
results are relevant for the development of future cryogenic particle detectors
using \SiPMs\ as photosensors
Development of a very low-noise cryogenic pre-amplifier for large-area SiPM devices
Silicon Photomultipliers (SiPMs) are an excellent candidate for the
development of large-area light sensors. Large SiPM-based detectors require
low-noise pre-amplifiers to maximize the signal coupling between the sensor and
the readout electronics. This article reports on the development of a low-noise
transimpedance amplifier sensitive to single-photon signals at cryogenic
temperature. The amplifier is used to readout a 1 cm SiPM with a signal
to noise ratio in excess of 40
Recommended from our members
Borexino : geo-neutrino measurement at Gran Sasso, Italy
Geo-neutrinos, electron anti-neutrinos produced in beta-decays of naturally occurring radioactive isotopes in the Earth, are a unique direct probe of our planet's interior. After a brief introduction of the geo-neutrinos' properties and of the main aims of their study, we discuss the features of a detector which has recently provided breakthrough achievements in the field, Borexino, a massive, calorimetric liquid scintillator detector installed at the underground Gran Sasso Laboratory. With its unprecedented radiopurity levels achieved in the core of the detection medium, it is the only experiment in operation able to study in real time solar neutrino interactions in the challenging sub-MeV energy region. Its superior technical properties allowed Borexino also to provide a clean detection of terrestrial neutrinos. Therefore, the description of the characteristics of the detected geo-neutrino signal and of the corresponding geological implications are the main core of the discussion contained in this work
Identifying a recombinant alkyldihydroxyacetonephosphate synthase suited for crystallographic studies
Alkyldihydroxyacetonephosphate is the building block for the biosynthesis of ether phospholipids, which are essential components of eukaryotic cell membranes and are involved in a variety of signaling processes. The metabolite is synthesized by alkyldihydroxyacetonephosphate synthase (ADPS), a peroxisomal flavoenzyme. Deficiency in ADPS activity causes rhizomelic chondrodysplasia punctata type 3, a very severe genetic disease. ADPS is unusual in that it uses a typical redox cofactor such as FAD to catalyze a non-redox reaction. With the goal of undertaking a structural investigation of the enzyme, we have characterized recombinant ADPS from different sources: Cavia porcellus, Drosophila melanogaster, Homo sapiens, Archaeoglobus fulgidus, and Dictyostelium discoideum. The protein from D. discoideum was found to be the best candidate for structural studies. We describe a protocol for expression and purification of large amounts of pure and stable enzyme in its holo (FAD-bound) form. A search of deletion mutants identified a protein variant that forms crystals diffracting up to 2A resolution
Measurement of CNGS Muon Neutrinos Speed with Borexino: INRIM and ROA Contribution
This paper describes the contribution given by the INRIM “Time and Frequency Laboratory” and the ROA “Time Department” to the Borexino cooperation in the experiments for the accurate measurement of the CNGS (CERN neutrinos to Gran Sasso) muon neutrinos speed. We briefly report about the design, installation, and performance of a new system called High Precision Timing Facility (HPTF), intended as a GPS-based timing facility with a calibrated time-link to the CERN GPS receiver and with continual real time monitoring of the fiber link time delay to the underground laboratory. Details about the INRIM/ROA contribution will be presented, reporting the calibration of the CERN-LNGS GPS time link, as well as the calibration of the HPTF internal delays. This system, specifically designed for the Borexino experiments, has also been made available to other LNGS experiments (namely, LVD and Icarus) and has been used to measure the muon neutrino speed in May 2012, during a special short bunch run of the CNGS beam
Development of a Novel Single-Channel, 24 cm 2
We report on the realization of a novel SiPM-based, cryogenic photosensor
with an active area of 24 cm that operates as a single-channel analog
detector. The device is capable of single photon counting with a signal to
noise ratio better than 13, a dark rate lower than cps/mm and an
overall photon detection efficiency significantly larger than traditional
photomultiplier tubes. This development makes SiPM-based photosensors strong
candidates for the next generation of dark matter and neutrino detectors, which
will require multiple square meters of photosensitive area, low levels of
intrinsic radioactivity and a limited number of detector channels
Development of a Novel Single-Channel, 24 cm(2), SiPM-Based, Cryogenic Photodetector
We report on the realization of a novel silicon photomultiplier (SiPM)-based, cryogenic photosensor with an active area of 24 cm(2) that operates as a single-channel analog detector. The device is capable of single-photon counting with a signal-to-noise ratio better than 13, a dark rate lower than 10(-2) Hz/mm(2), and an overall photon detection efficiency significantly larger than traditional photomultiplier tubes. This development makes SiPM-based photosensors strong candidates for the next generation of dark matter and neutrino detectors, which will require multiple square meters of photosensitive area, low levels of intrinsic radioactivity, and a limited number of detector channels