15 research outputs found

    Bifurcation treatment with novel, highly flexible drug-eluting coronary stents in all-comers: 2-year outcome in patients of the DUTCH PEERS trial

    Get PDF
    Background: Percutaneous coronary intervention (PCI) in bifurcated lesions with second-generation drug-eluting stents (DES) was associated with increased myocardial infarction (MI) rates. Flexible stent designs that accommodate well to vessel tapering may be of benefit in challenging anatomies such as bifurcated target lesions, but so far data are scarce.Methods: We analyzed the 2-year follow-up data of the DUTCH PEERS (TWENTE II) trial, which randomized 1811 all-comer patients to PCI with newer generation resolute integrity zotarolimus-eluting (Medtronic) or promus element everolimus-eluting stents (Boston Scientific). In bifurcated lesions, provisional stenting was generally performed. Target vessel failure is a composite endpoint, consisting of cardiac death, target vessel MI, or target vessel revascularization.Results: Patients with at least one bifurcated lesion (n = 465, 25.7 %) versus patients with non-bifurcated target lesions only (n = 1346, 74.3 %) showed similar rates of clinical endpoints including target vessel failure (9.2 versus 7.9 %, p = 0.36) and definite stent thrombosis (0.4 versus 1.0 %, p = 0.38). Target vessel MI was more common in patients with bifurcated lesions (3.4 versus 1.6 %, p = 0.02); but after multivariate analysis with propensity score adjustment, bifurcation treatment was found not to be an independent predictor of target vessel MI (HR 1.40, 95 % CI 0.71–2.76; p = 0.34). Among patients with bifurcated lesions, DES type and side-branch size did not affect outcome, but periprocedural MI occurred more often after two-stent approaches (9.0 versus 2.1 %; p = 0.002).Conclusion: All-comer patients treated for bifurcated and non-bifurcated target lesions showed similar and low rates of clinical endpoints, suggesting that the DES used are efficacious and safe for treating bifurcated target lesions

    Impact of severe lesion calcification on clinical outcome of patients with stable angina, treated with newer generation permanent polymer-coated drug-eluting stents: A patient-level pooled analysis from TWENTE and DUTCH PEERS (TWENTE II)

    Get PDF
    Background The outcome of percutaneous coronary intervention with newer generation permanent polymer-coated drug-eluting stents (DES) in patients with severely calcified lesions is greatly unknown. We assessed the impact of severe lesion calcification on clinical outcome in patients with stable angina who underwent percutaneous coronary intervention with newer generation DES. Methods TWENTE and DUTCH PEERS randomized trials enrolled 1423 patients with stable angina, who were categorized into patients with versus without severe target lesion calcification. A patient-level pooled analysis assessed clinical outcome, including target vessel failure (TVF), a composite of cardiac death, target vessel-related myocardial infarction, or target vessel revascularization (TVR). Results Patients with severe calcification (n = 342) were older (66.6 ± 9.1 vs 64.2 ± 9.8 years, P < .001) and had more diabetes (25.7% vs 20.4%, P = .04) than other patients (n = 1081). Patients with calcified lesions had higher rates of TVF (16.4% vs 9.8%, pLogrank = .001), cardiac death (4.4% vs 1.5%, P = .03), target vessel myocardial infarction (7.6% vs 3.4%, P = .001), and definite stent thrombosis (1.8% vs 0.4%, P = .02). Multivariate analysis demonstrated that severe calcification was an independent risk factor of 2-year TVF (HR 1.42, 95% CI: 1.02-1.99, pLogrank = .04); landmark analysis showed that this was based on a difference during the first year (periprocedural: 5.8% vs. 3.1%, pLogrank = .02; first year: 7.5% vs. 3.8%, pLogrank = .007; second year: 4.1% vs. 3.3%, pLogrank = .54). Conclusion In patients with stable angina, severe target lesion calcification is associated with an increased risk of adverse cardiovascular events following treatment with newer generation permanent polymer-coated DES. This increase in risk is restricted to the first year of follow-up, which is an encouraging finding

    Three-year safety and efficacy of treating all-comers with newer-generation Resolute Integrity or PROMUS Element stents in the randomised Dutch PEERS (TWENTE II) trial

    Get PDF
    Aims: The aim of this report was to assess the three-year safety and efficacy of implanting newer-generation Resolute Integrity zotarolimus-eluting stents (ZES) versus PROMUS Element everolimus-eluting stents (EES) in all-comers. Methods and results: In the randomised, multicentre, investigator-initiated Dutch PEERS trial, a total of 1,811 all-comers were 1:1 randomly assigned to treatment with ZES versus EES. A total of 1,293 patients (72%) were treated for complex lesions and 455 patients (25%) were treated for multiple lesions. The primary endpoint target vessel failure (TVF) is a composite of cardiac death, target vessel-related myocardial infarction or target vessel revascularisation. Adverse clinical events were independently adjudicated. Three-year follow-up data were obtained in 1,807 patients (99.8%, four withdrawals). Both the ZES and EES groups showed favourable outcomes with a similar incidence of TVF (10.7% vs. 10.3%; pLog-rank =0.77) and the individual components thereof: cardiac death (3.2% vs. 3.1%; pLog-rank=0.87), target vessel-related myocardial infarction (2.8% vs. 2.2%; pLog-rank =0.44) and target vessel revascularisation (6.0% vs. 6.2%; pLog-rank =0.87). In addition, the incidence of definite or probable stent thrombosis was similar for patients treated with ZES versus EES (1.4% vs. 1.1%; pLog-rank =0.66). Conclusions: The safety and efficacy of treating all-comers with newer-generation Resolute Integrity and PROMUS Element stents was found to be extended up to three years

    Three-Year Clinical Outcome of Patients with Coronary Disease and Increased Event Risk Treated with Newer-Generation Drug-Eluting Stents: From the Randomized DUTCH PEERS Trial

    No full text
    Objective: Limited data is available on the long-term outcome of patients with increased cardiovascular event risk, treated with newer-generation durable polymer drug-eluting stents (DES). Methods: We therefore assessed 3-year follow-up data of high-risk versus low-to intermediate-risk patients of the randomized DUTCH PEERS trial (NCT01331707). In both risk groups we also compared patients treated with Resolute Integrity versus Promus Element DES. Patients were categorized as "high-risk" if they met ≥1 of the following criteria: (1) diabetes (17.9%); (2) previous myocardial infarction (21.9%); (3) previous coronary revascularization (25.8%); (4) chronic renal failure (3.5%); (5) left ventricular ejection fraction ≤30% (1.5%); and (6) age ≥75 years (17.3%). Results: At the 3-year follow-up, the incidence of the composite endpoint target vessel failure (TVF) (13.2 vs. 7.5%; logrank p < 0.001) and 2 of its components-cardiac death (4.7 vs. 1.5%; logrank p < 0.001) and target vessel revascularization (7.3 vs. 4.7%; logrank p = 0.03)-was higher in high-risk (n = 957) versus low-to intermediate-risk patients (n = 854). Among high-risk patients, treatment with Resolute Integrity (n = 481) and Promus Element stents (n = 476) was similarly safe and efficacious (TVF: 13.3 vs. 13.1%; logrank p = 0.95; definite-or-probable stent thrombosis: 1.7 vs. 1.7%; logrank p = 1.00). Conclusions: The newer-generation Resolute Integrity and Promus Element stents showed similar results in terms of safety and efficacy for treating high-risk patients, who had significantly higher event rates than patients with low-to-intermediate risk

    Pharmacodynamic effect and clinical efficacy of clopidogrel and prasugrel with or without a proton-pump inhibitor: an analysis of two randomised trials

    No full text
    BACKGROUND: Proton-pump inhibitors (PPIs) are often prescribed in combination with thienopyridines. Conflicting data exist as to whether PPIs diminish the efficacy of clopidogrel. We assessed the association between PPI use, measures of platelet function, and clinical outcomes for patients treated with clopidogrel or prasugrel. METHODS: In the PRINCIPLE-TIMI 44 trial, the primary outcome was inhibition of platelet aggregation at 6 h assessed by light-transmission aggregometry. In the TRITON-TIMI 38 trial, the primary endpoint was the composite of cardiovascular death, myocardial infarction, or stroke. In both studies, PPI use was at physician\u27s discretion. We used a multivariable Cox model with propensity score to assess the association of PPI use with clinical outcomes. FINDINGS: In the PRINCIPLE-TIMI 44 trial, 201 patients undergoing elective percutaneous coronary intervention were randomly assigned to prasugrel (n=102) or high-dose clopidogrel (n=99). Mean inhibition of platelet aggregation was significantly lower for patients on a PPI than for those not on a PPI at 6 h after a 600 mg clopidogrel loading dose (23.2+/-19.5% vs 35.2+/-20.9%, p=0.02), whereas a more modest difference was seen with and without a PPI after a 60 mg loading dose of prasugrel (69.6+/-13.5% vs 76.7+/-12.4%, p=0.054). In the TRITON-TIMI 38 trial, 13,608 patients with an acute coronary syndrome were randomly assigned to prasugrel (n=6813) or clopidogrel (n=6795). In this study, 33% (n=4529) of patients were on a PPI at randomisation. No association existed between PPI use and risk of the primary endpoint for patients treated with clopidogrel (adjusted hazard ratio [HR] 0.94, 95% CI 0.80-1.11) or prasugrel (1.00, 0.84-1.20). INTERPRETATION: The current findings do not support the need to avoid concomitant use of PPIs, when clinically indicated, in patients receiving clopidogrel or prasugrel. FUNDING: Daiichi Sankyo Company Limited and Eli Lilly and Company sponsored the trials. This analysis had no funding

    5-Year Outcome Following Randomized Treatment of All-Comers With Zotarolimus-Eluting Resolute Integrity and Everolimus-Eluting PROMUS Element Coronary Stents: Final Report of the DUTCH PEERS (TWENTE II) Trial

    Get PDF
    Objectives: The study sought to evaluate for the first time the 5-year outcomes after treating an all-comers population with newer-generation cobalt chromium-based Resolute Integrity zotarolimus-eluting stents (ZES) (Medtronic, Santa Rosa, California) versus platinum chromium-based PROMUS Element everolimus eluting stents (EES) (Boston Scientific, Natick, Massachusetts). Background: The DUTCH PEERS (TWENTE II) (DUrable polymer-based sTent CHallenge of Promus ElemEnt versus ReSolute integrity: TWENTE II) trial is a randomized, multicenter, single-blinded, investigator-initiated all-comers trial that found at its main analysis similar 1-year safety and efficacy for both drug-eluting stents. It is the first randomized trial ever to investigate the Resolute Integrity ZES and the first trial to compare both devices. Methods: In total, 1,811 patients were 1:1 randomized to ZES versus EES. We performed a pre-specified assessment of the 5-year clinical outcomes in terms of safety and efficacy. The main endpoint target vessel failure (TVF) is a composite of cardiac death, target vessel–related myocardial infarction, or target vessel revascularization. Secondary endpoints included the individual components of TVF, and stent thrombosis. The study was independently monitored, and adverse clinical events were independently adjudicated. Results: Five-year clinical follow-up data was available in 1,798 (99.3%) patients. The ZES and EES groups showed favorable outcomes, with similar 5-year incidence of TVF (13.2% vs. 14.2%; plog-rank = 0.62) and its individual components: cardiac death (4.5% vs. 4.9%; plog-rank = 0.69), target vessel–related myocardial infarction (3.1% vs. 2.6%; plog-rank = 0.47), and target vessel revascularization (7.6% vs. 8.6%; plog-rank = 0.46). The 5-year incidence of definite or probable stent thrombosis was similar (1.5% vs. 1.3%; plog-rank = 0.83). Conclusions: At 5-year follow-up, the Resolute Integrity ZES and PROMUS Element EES showed similar and sustained results in terms of safety and efficacy for treating a broad population of all-comers

    Predictors of coronary stent thrombosis: the Dutch Stent Thrombosis Registry.

    No full text
    Contains fulltext : 81893.pdf (publisher's version ) (Closed access)OBJECTIVES: This study sought to comprehensively identify predictors of stent thrombosis (ST). BACKGROUND: Given the devastating consequences of ST, efforts should be directed toward risk stratification to identify patients at highest risk for ST. METHODS: Consecutive patients with angiographic ST were enrolled. Patients who did not suffer from a ST were randomly selected in a 2:1 ratio and were matched for: 1) percutaneous coronary intervention (PCI) indication; 2) same date of index PCI; and 3) same interventional center. RESULTS: Of 21,009 patients treated with either a bare-metal or drug-eluting stent, 437 patients (2.1%) presented with a definite ST. A total of 140 STs were acute, 180 were subacute, 58 were late, and 59 were very late. Undersizing of the coronary stent, Thrombolysis In Myocardial Infarction flow grade or=50% to <70% stenosis) coronary artery disease proximal to the culprit lesion were the strongest predictors of ST
    corecore