143 research outputs found

    Minimally invasive reconstruction of lateral tibial plateau fractures using the jail technique: a biomechanical study

    Get PDF
    BACKGROUND: This study described a novel, minimally invasive reconstruction technique of lateral tibial plateau fractures using a three-screw jail technique and compared it to a conventional two-screw osteosynthesis technique. The benefit of an additional screw implanted in the proximal tibia from the anterior at an angle of 90° below the conventional two-screw reconstruction after lateral tibial plateau fracture was evaluated. This new method was called the jail technique. METHODS: The two reconstruction techniques were tested using a porcine model (n = 40). Fracture was simulated using a defined osteotomy of the lateral tibial plateau. Load-to-failure and multiple cyclic loading tests were conducted using a material testing machine. Twenty tibias were used for each reconstruction technique, ten of which were loaded in a load-to-failure protocol and ten cyclically loaded (5000 times) between 200 and 1000 N using a ramp protocol. Displacement, stiffness and yield load were determined from the resulting load displacement curve. Failure was macroscopically documented. RESULTS: In the load-to-failure testing, the jail technique showed a significantly higher mean maximum load (2275.9 N) in comparison to the conventional reconstruction (1796.5 N, p < 0.001). The trend for better outcomes for the novel technique in terms of stiffness and yield load did not reach statistical significance (p > 0.05). In cyclic testing, the jail technique also showed better trends in displacement that were not statistically significant. Failure modes showed a tendency of screws cutting through the bone (cut-out) in the conventional reconstruction. No cut-out but a bending of the lag screws at the site of the additional third screw was observed in the jail technique. CONCLUSIONS: The results of this study indicate that the jail and the conventional technique have seemingly similar biomechanical properties. This suggests that the jail technique may be a feasible alternative to conventional screw osteosynthesis in the minimally invasive reconstruction of lateral tibial plateau fractures. A potential advantage of the jail technique is the prevention of screw cut-outs through the cancellous bone

    Management of an extended clivus fracture: a case report

    Get PDF
    Background: Clivus fractures are highly uncommon. The classification by Corradino et al. divides the different lesions in longitudinal, transverse and oblique fractures. Longitudinal types are associated with the highest mortality rate between 67 – 80%. Clivus fractures are often found after high velocity trauma, especially traffic accidents and falls. The risk of neurologic lesions is high, because of the anatomic proximity to neurovascular structures like the brainstem, the vertebrobasilar artery, and the cranial nerves. Longitudinal clivus fractures have a special risk of causing entrapment of the basilar artery and thus ischemia of the brainstem. Case presentation: This lesion in our patient was a combination-fracture of the craniocervical junction with a transverse clivus fracture. In this case, the primary closed reduction of the clivus fracture and the immobilization with a halo device was the therapy of choice and led to consolidation of the fracture. Conclusion: Therapy advices and examples in the literature are scarce. We present a patient with a clivus fracture, who could be well treated by a halo device. Through detailed research of the literature a therapy algorithm has been developed.<br

    Therapy of intracellular Staphylococcus aureus by tigecyclin

    Get PDF
    BACKGROUND: In the fields of traumatology and orthopaedics staphylococci are the most frequently isolated pathogens. Staphylococcus aureus and Staphylococcus epidermidis are known to be the major causative agents of osteomyelitis. The increasing number of multiresistant Staphylococcus aureus and resistant coagulase-negative staphylococci as a trigger of complicated osteomyelitis and implant-associated infections is a major problem. Antibiotic therapy fails in 20% of cases. Therefore the development of novel antibiotics becomes necessary. METHODS: This study analyses tigecyclin, the first antibiotic of the glycylines, as a potential therapy for osteomyelitis caused by multiresistant Staphylococcus aureus. Therefore its intracellular activity and the potential use in polymethylmetacrylate-bone cement are examined. The intracellular activity of tigecyclin is determined by a human osteoblast infection model. The investigation of the biomechanical characteristics is conducted concerning the ISO 5833-guidelines. RESULTS: Tigecyclin shows in vitro an intracellular activity that ranges between the antimicrobial activity of gentamicin and rifampicin. A significant negative effect on the biomechanical characteristics with an impaired stability is detected after adding tigecyclin to polymethylmetacrylate-bone cement with a percentage of 1.225% per weight. CONCLUSIONS: This study shows that tigecyclin might be a potent alternative for the systemic therapy of osteomyelitis and implant-associated infections whereas the local application has to be reconsidered individually

    An unusual cause of ankle pain: fracture of a talocalcaneal coalition as a differential diagnosis in an acute ankle sprain: a case report and literature review

    Full text link
    Background: The acute ankle sprain is one of the most common injuries seen in trauma departments. Ankle sprains have an incidence of about one injury per 10 000 people a day. In contrast tarsal coalition is a rare condition occurring in not more than one percent of the population. Case presentation: We present the case of a 23 year old male patient with pain and local swelling after an acute ankle sprain. Initial clinical and radiological examination showed no pathologies. Due to prolonged pain, swelling and the inability of the patient to weight bear one week after trauma further diagnostics was performed. Imaging studies (MRI and CT) revealed a fracture of a talocalcaneal coalition. To the knowledge of the authors no fracture of a coalition was reported so far. Conclusion: This report highlights the presentation of symptomatic coalitions following trauma and furthermore, it points out the difficulties in the diagnosis and treatment of a rare entity after a common injury. A diagnostic algorithm has been developed to ensure not to miss a severe injury.<br

    Risk factors for infectious complications after open fractures; a systematic review and meta-analysis

    Get PDF
    __Purpose__ The purpose of this study was to identify risk factors for the development of infection after open fracture fixation. __Methods__ A comprehensive search in all scientific literature of the last 30 years was performed in order to identify patient-, trauma-, diagnosis- and treatment-related risk f

    Biomechanical Analysis of the Efficacy of Locking Plates during Cyclic Loading in Metacarpal Fractures

    Get PDF
    Purpose. To analyse the biomechanical characteristics of locking plates under cyclic loading compared to a nonlocking plate in a diaphyseal metacarpal fracture. Methods. Oblique diaphyseal shaft fractures in porcine metacarpal bones were created in a biomechanical fracture model. An anatomical reduction and stabilization with a nonlocking and a comparable locking plate in mono- or bicortical screw fixation followed. Under cyclic loading, the displacement, and in subsequent load-to-failure tests, the maximum load and stiffness were measured. Results. For the monocortical screw fixation of the locking plate, a similar displacement, maximum load, and stiffness could be demonstrated compared to the bicortical screw fixation of the nonlocking plate. Conclusions. Locking plates in monocortical configuration may function as a useful alternative to the currently common treatment with bicortical fixations. Thereby, irritation of the flexor tendons would be avoided without compromising the stability, thus enabling the necessary early functional rehabilitation

    Challenges and barriers to improving care of the musculoskeletal patient of the future - a debate article and global perspective

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>With greater technological developments in the care of musculoskeletal patients, we are entering an era of rapid change in our understanding of the pathophysiology of traumatic injury; assessment and treatment of polytrauma and related disorders; and treatment outcomes. In developed countries, it is very likely that we will have algorithms for the approach to many musculoskeletal disorders as we strive for the best approach with which to evaluate treatment success. This debate article is founded on predictions of future health care needs that are solely based on the subjective inputs and opinions of the world's leading orthopedic surgeons.</p> <p>Hence, it functions more as a forum-based rather than a scientific-based presentation. This exposĂŠ was designed to stimulate debate about the emerging patients' needs in the future predicted by leading orthopedic surgeons that provide some hint as to the right direction for orthopedic care and outlines the important topics in this area.</p> <p>Discussion</p> <p>The authors aim to provide a general overview of orthopedic care in a typical developed country setting. However, the regional diversity of the United States and every other industrialized nation should be considered as a cofactor that may vary to some extent from our vision of improved orthopedic and trauma care of the musculoskeletal patient on an interregional level.</p> <p>In this forum, we will define the current and future barriers in developed countries related to musculoskeletal trauma, total joint arthroplasty, patient safety and injuries related to military conflicts, all problems that will only increase as populations age, become more mobile, and deal with political crisis.</p> <p>Summary</p> <p>It is very likely that the future will bring a more biological approach to fracture care with less invasive surgical procedures, flexible implants, and more rapid rehabilitation methods. This international consortium challenges the trauma and implants community to develop outcome registries that are managed through health care offices and to prepare effectively for the many future challenges that lie in store for those who treat musculoskeletal conditions.</p

    Compliance to Screening Protocols for Multidrug-Resistant Microorganisms at the Emergency Departments of Two Academic Hospitals in the Dutch-German Cross-Border Region

    Get PDF
    Infections caused by multidrug-resistant organisms (MDROs) are associated with prolonged hospitalization and higher risk of mortality. Patients arriving in the hospital via the emergency department (ED) are screened for the presence of MDROs in compliance with the screening protocols in order to apply the correct isolation measures. In the Dutch-German border region, local hospitals apply their own screening protocols which are based upon national screening protocols. The contents of the national and local MDRO screening protocols were compared on vancomycin-resistant enterococci (VRE), methicillin-resistant Staphylococcus aureus (MRSA), and carbapenemase-producing and carbapenem-resistant Enterobacteriaceae (CPE/CRE). The practicality of the screening protocols was evaluated by performing an audit. As a result, the content of the MDRO screening protocols differed regarding risk factors for MDRO carriage, swab site, personal protective equipment, and isolation measures. The observations and questionnaires showed that the practicality was sufficient; however, the responsibility was not designated clearly and education regarding the screening protocols was deemed inappropriate. The differences between the MDRO screening protocols complicate patient care in the Dutch-German border region. Arrangements have to be made about the responsibility of the MDRO screening, and improvements are necessary concerning education regarding the MDRO screening protocols

    A Trans-Atlantic Perspective on Stagnation in Clinical Translation of Antimicrobial Strategies for the Control of Biomaterial-Implant-Associated Infection

    Get PDF
    Current regulatory requirements impede clinical translation and market introduction of many new antimicrobial combination implants and devices, causing unnecessary patient suffering, doctor frustration, and costs to healthcare payers. Regulatory requirements of antimicrobial combination implants and devices should be thoroughly revisited and their approval allowed based on enrichment of benefit demonstrations from high-risk patient groups and populations or device components to facilitate their clinical translation. Biomaterial implant and devices equipped with antimicrobial strategies and approved based on enrichment claims should be mandatorily enrolled in global registry studies supervised by regulatory agencies for a minimum five-year period or until statistically validated evidence for noninferiority or superiority of claims is demonstrated. With these recommendations, this trans-Atlantic consortium of academicians and clinicians takes its responsibility to actively seek to relieve the factors that stagnate downward clinical translation and availability of antimicrobial combination implants and devices. Improved dialogue between the various key players involved in the current translational blockade, which include patients, academicians and doctors, policymakers, regulatory agencies, manufacturers, and healthcare payers, is urgently needed.</p
    • …
    corecore