1,215 research outputs found

    Extracorporeal CO2 removal in hypercapnic patients who fail noni nvasive ventialtion and refuse endotracheal intubation. a case series

    Get PDF
    Noninvasive ventilation (NIV) represents the standard of care for patients with exacerbation of chronic obstructive pulmonary disease. However, NIV fails in almost 40% of the most severe forms of acute hypercapnic respiratory failure and patients must undergo endotracheal intubation and invasive ventilation. Such transition from NIV to invasive ventilation is associated to increased mortality. Under these circumstances, patients may express a clear intention not to be intubated

    Heart rate reduction with esmolol is associated with improved arterial elastance in patients with septic shock: a prospective observational study

    Get PDF
    PURPOSE: Ventricular–arterial (V–A) decoupling decreases myocardial efficiency and is exacerbated by tachycardia that increases static arterial elastance (Ea). We thus investigated the effects of heart rate (HR) reduction on Ea in septic shock patients using the beta-blocker esmolol. We hypothesized that esmolol improves Ea by positively affecting the tone of arterial vessels and their responsiveness to HR-related changes in stroke volume (SV). METHODS: After at least 24 h of hemodynamic optimization, 45 septic shock patients, with an HR ≥95 bpm and requiring norepinephrine to maintain mean arterial pressure (MAP) ≥65 mmHg, received a titrated esmolol infusion to maintain HR between 80 and 94 bpm. Ea was calculated as MAP/SV. All measurements, including data from right heart catheterization, echocardiography, arterial waveform analysis, and norepinephrine requirements, were obtained at baseline and at 4 h after commencing esmolol. RESULTS: Esmolol reduced HR in all patients and this was associated with a decrease in Ea (2.19 ± 0.77 vs. 1.72 ± 0.52 mmHg l−1), arterial dP/dtmax (1.08 ± 0.32 vs. 0.89 ± 0.29 mmHg ms−1), and a parallel increase in SV (48 ± 14 vs. 59 ± 18 ml), all p < 0.05. Cardiac output and ejection fraction remained unchanged, whereas norepinephrine requirements were reduced (0.7 ± 0.7 to 0.58 ± 0.5 µg kg−1 min−1, p < 0.05). CONCLUSIONS: HR reduction with esmolol effectively improved Ea while allowing adequate systemic perfusion in patients with severe septic shock who remained tachycardic despite standard volume resuscitation. As Ea is a major determinant of V–A coupling, its reduction may contribute to improving cardiovascular efficiency in septic shock

    A new automated method versus continuous positive airway pressure method for measuring pressure-volume curves in patients with acute lung injury

    Get PDF
    Objective: To compare pressure-volume (P-V) curves obtained with the Galileo ventilator with those obtained with the CPAP method in patients with ALI or ARDS receiving mechanical ventilation. P-V curves were fitted to a sigmoidal equation with a mean R2 of 0.994 ± 0.003. Lower (LIP) and upper inflection (UIP), and deflation maximum curvature (PMC) points calculated from the fitted variables showed a good correlation between methods with high intraclass correlation coefficients. Bias and limits of agreement for LIP, UIP and PMC obtained with the two methods in the same patient were clinically acceptable.Comparar les curves pressió-volum (PV) realitzades amb el ventilador Galileo amb aquelles realitzades amb el mètode CPAP, en malalts amb LPA/SDRA tractats amb ventilació mecànica. Les curves PV vàren ésser ajustades a una equació sigmoidal, amb una R2 de 0.994 ± 0.003. Els punts d'inflexió inferior (PII), superior (PSI) i el punt de màxima curvatura de la curva espiratòria (PMC) calculats vàren mostrar una bona correlació entres els mètodes, amb coeficients de correlació intra-classe molt alts. El biaix i els límits d'acord per PII, PSI i PMC aconseguits amb els mètodes en el mateix malalt vàren ésser clínicament acceptables
    corecore