1,383 research outputs found

    Position paper: Models of post-transplant care for individuals with cystic fibrosis

    Get PDF
    There is no consensus on the best model of care for individuals with CF to manage the non-pulmonary complications that persist after lung transplant. The CF Foundation virtually convened a group of international experts in CF and lung-transplant care. The committee reviewed literature and shared the post-lung transplant model of care practiced by their programs. The committee then developed a survey that was distributed internationally to both the clinical and individual with CF/family audiences to determine the strengths, weaknesses, and preferences for various models of transplant care. Discussion generated two models to accomplish optimal CF care after transplant. The first model incorporates the CF team into care and proposes delineation of responsibilities for the CF and transplant teams. This model is reliant on outstanding communication between the teams, while leveraging the expertise of the CF team for management of the non-pulmonary manifestations of CF. The transplant team manages all aspects of the transplant, including pulmonary concerns and management of immunosuppression. The second model consolidates care in one center and may be more practical for transplant programs that have expertise managing CF and have access to CF multidisciplinary care team members (e.g., located in the same institution). The best model for each program is influenced by several factors and model selection needs to be decided between the transplant and the CF center and may vary from center to center. In either model, CF lung transplant recipients require a clear delineation of the roles and responsibilities of their providers and mechanisms for effective communication

    Novel muon imaging techniques

    Get PDF
    Owing to the high penetrating power of high-energy cosmic ray muons, muon imaging techniques can be used to image large bulky objects, especially objects with heavy shielding. Muon imaging systems work just like CT scanners in the medical imaging field—that is, they can reveal information inside of a target. There are two forms of muon imaging techniques: muon absorption imaging and muon multiple scattering imaging. The former is based on the flux attenuation of muons, and the latter is based on the multiple scattering of muons in matter. The muon absorption imaging technique is capable of imaging very large objects such as volcanoes and large buildings, and also smaller objects like spent fuel casks; the muon multiple scattering imaging technique is best suited to inspect smaller objects such as nuclear waste containers. Muon imaging techniques can be applied in a broad variety of fields, i.e. from measuring the magma thickness of volcanoes to searching for secret cavities in pyramids, and from monitoring the borders of countries checking for special nuclear materials to monitoring the spent fuel casks for nuclear safeguards applications. In this paper, the principles of muon imaging are reviewed. Image reconstruction algorithms such as Filtered Back Projection and Maximum Likelihood Expectation Maximization are discussed. The capability of muon imaging techniques is demonstrated through a Geant4 simulation study for imaging a nuclear spent fuel cask

    Measurement of the γ + 4He total photoabsorption cross-section using a gas-scintillator active target

    Get PDF
    A large number of experiments have been performed in the past 60 years in an attempt to understand the near threshold photodisintegration of 4He. Available experimental data are inconsistent and do not provide reliable guidance for theoretical calculations for the total and partial cross-sections in the energy regime near breakup threshold. Even with the most recent experimental work done on the subject, the situation still has not been fully clarified. This thesis reports a measurement of the total cross-section for photodisintegration of 4He below pi-production threshold, carried out in 2009 at the up-graded tagged photon facility at MAX-lab in Lund, Sweden, in collaboration with the Photonuclear group of Lund University. The aim of this measurement is to provide a reliable and precise set of data so that the accuracy of theoretical models can be judged reliably. The experiment was performed using a Helium Gas-Scintillator Active Target (HGSAT), built and developed at the University of Glasgow. The helium target acts also as a detector of the 4He photodisintegration charged products. A photon beam, energy tagged in the range 11-68 MeV, was directed towards the HGSAT, which operated at a pressure of 2MPa, at room temperature. The resultant scintillation is collected and detected by a number of photomultiplier tubes (PMT) mounted on the HGSAT. 12 external neutron detectors and two 10" sodium iodide (NaI) detectors were used during the experiment to distinguish 4He(γ,n)3He and 4He(γ,γ')4He events, although these events have not been analysed here. The tagged photon coincidence signal was separated from random background using two methods: background filtering and fitting procedure. The two methods produced similar results. A Geant4-based Monte-Carlo simulation was developed to derive the HGSAT detection efficiency. Trigger thresholds needed in the simulation were estimated by evaluation and matching the normalised yield to previously measured γ+4He cross-sections above 40 MeV where more consistency in the dataset is observed, hence the results presented in this thesis are preliminary and will remain so until the absolute detection efficiency is determined. The preliminary total γ+4He cross-section obtained in this work peaks at ~2.85mb at a photon energy (Eγ) of ~27MeV, falling to ~1mb at Eγ = 60MeV. The measured cross-section is compared with previous data and recent theoretical calculations made using the Lorentz Integral Transform (LIT) technique. The present cross-section is already in reasonable agreement with the theoretical calculations and a number of previous experimental data. Future work to reduce systematic uncertainties will include analysis of the pulse height response of the HGSAT and further lower intensity experimental runs

    Cystic Fibrosis Foundation consensus statements for the care of Cystic Fibrosis Lung Transplant Recipients

    Get PDF
    Cystic fibrosis (CF) is the indication for transplantation in approximately 15% of recipients worldwide, and Cystic Fibrosis Lung Transplant Recipients (CFLTRs) have excellent long-term outcomes. Yet, CFLTRs have unique comorbidities that require specialized care. The objective of this document is to provide recommendations to CF and lung transplant clinicians for the management of perioperative and underlying comorbidities of CFLTRs and the impact of transplantation on these comorbidities. The Cystic Fibrosis Foundation (CFF) organized a multidisciplinary committee to develop CF Lung Transplant Clinical Care Recommendations. Three workgroups were formed to develop focused questions. Following a literature search, consensus recommendations were developed by the committee members based on literature review, committee experience and iterative revisions, and in response to public comment. The committee formulated 32 recommendation statements in the topics related to infectious disease, endocrine, gastroenterology, pharmacology, mental health and family planning. Broadly, the committee recommends close coordination of care between the lung transplant team, the cystic fibrosis care center, and specialists in other disciplines with experience in the care of CF and lung transplant recipients. These consensus statements will help lung transplant providers care for CFLTRs in order to improve post-transplant outcomes in this population

    Pragmatic application of the RE-AIM framework to evaluate the implementation of tobacco cessation programs within NCI-Designated Cancer Centers

    Get PDF
    Tobacco cessation after cancer diagnosis leads to better patient outcomes. However, tobacco treatment services are frequently unavailable in cancer care settings, and multilevel implementation challenges can impede uptake of new programs. The National Cancer Institute (NCI) dedicated Cancer Moonshot funding through the Cancer Center Cessation Initiative (C3I) for NCI-Designated Cancer Centers to implement or enhance the implementation of tobacco treatment services. We examined a pragmatic application of the RE-AIM framework (reach, effectiveness, adoption, implementation, and maintenance) to evaluate tobacco treatment programs implemented within Cancer Centers funded through C3I. Using three C3I-funded Centers as examples, we describe how each RE-AIM construct was operationalized to evaluate the implementation of a wide range of cessation services (e.g., tobacco use screening, counseling, Quitline referral, pharmacotherapy) in this heterogeneous group of cancer care settings. We discuss the practical challenges encountered in assessing RE-AIM constructs in real world situations, including using the electronic health record (EHR) to aid in assessment. Reach and effectiveness evaluation required that Centers define the setting(s) where cessation services were implemented (to determine the denominator ), enumerate the patient population, report current patient tobacco use, patient engagement in tobacco treatment, and 6-month cessation outcomes. To reduce site heterogeneity, increase data accuracy, and reduce burden, reach was frequently captured via standardized EHR enhancements that improved the identification of current smokers and tobacco treatment referrals. Effectiveness was determined by cessation outcomes (30-day point prevalence abstinence at 6-months post-engagement) assessed through a variety of data collection approaches. Adoption was measured by the characteristics and proportion of targeted cancer care settings and clinicians engaged in cessation service delivery. Implementation was assessed by examining the delivery of tobacco screening assessments and intervention components across sites, and provider-level implementation consistency. Maintenance assessments identified whether tobacco treatment services continued in the setting after implementation and documented the sustainability plan and organizational commitment to continued delivery. In sum, this paper demonstrates a pragmatic approach to using RE-AIM as an evaluation framework that yields relevant outcomes on common implementation metrics across widely differing tobacco treatment approaches and settings

    Implementation of health IT for cancer screening in US primary care: Scoping review

    Get PDF
    BACKGROUND: A substantial percentage of the US population is not up to date on guideline-recommended cancer screenings. Identifying interventions that effectively improve screening rates would enhance the delivery of such screening. Interventions involving health IT (HIT) show promise, but much remains unknown about how HIT is optimized to support cancer screening in primary care. OBJECTIVE: This scoping review aims to identify (1) HIT-based interventions that effectively support guideline concordance in breast, cervical, and colorectal cancer screening provision and follow-up in the primary care setting and (2) barriers or facilitators to the implementation of effective HIT in this setting. METHODS: Following scoping review guidelines, we searched MEDLINE, CINAHL Plus, Web of Science, and IEEE Xplore databases for US-based studies from 2015 to 2021 that featured HIT targeting breast, colorectal, and cervical cancer screening in primary care. Studies were dual screened using a review criteria checklist. Data extraction was guided by the following implementation science frameworks: the Reach, Effectiveness, Adoption, Implementation, and Maintenance framework; the Expert Recommendations for Implementing Change taxonomy; and implementation strategy reporting domains. It was also guided by the Integrated Technology Implementation Model that incorporates theories of both implementation science and technology adoption. Reporting was guided by PRISMA-ScR (Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews). RESULTS: A total of 101 studies met the inclusion criteria. Most studies (85/101, 84.2%) involved electronic health record-based HIT interventions. The most common HIT function was clinical decision support, primarily used for panel management or at the point of care. Most studies related to HIT targeting colorectal cancer screening (83/101, 82.2%), followed by studies related to breast cancer screening (28/101, 27.7%), and cervical cancer screening (19/101, 18.8%). Improvements in cancer screening were associated with HIT-based interventions in most studies (36/54, 67% of colorectal cancer-relevant studies; 9/14, 64% of breast cancer-relevant studies; and 7/10, 70% of cervical cancer-relevant studies). Most studies (79/101, 78.2%) reported on the reach of certain interventions, while 17.8% (18/101) of the included studies reported on the adoption or maintenance. Reported barriers and facilitators to HIT adoption primarily related to inner context factors of primary care settings (eg, staffing and organizational policies that support or hinder HIT adoption). Implementation strategies for HIT adoption were reported in 23.8% (24/101) of the included studies. CONCLUSIONS: There are substantial evidence gaps regarding the effectiveness of HIT-based interventions, especially those targeting guideline-concordant breast and colorectal cancer screening in primary care. Even less is known about how to enhance the adoption of technologies that have been proven effective in supporting breast, colorectal, or cervical cancer screening. Research is needed to ensure that the potential benefits of effective HIT-based interventions equitably reach diverse primary care populations

    Integrating tobacco treatment into oncology care: Reach and effectiveness of evidence-based tobacco treatment across National Cancer Institute-designated cancer centers

    Get PDF
    PURPOSE: Quitting smoking improves patients\u27 clinical outcomes, yet smoking is not commonly addressed as part of cancer care. The Cancer Center Cessation Initiative (C3I) supports National Cancer Institute-designated cancer centers to integrate tobacco treatment programs (TTPs) into routine cancer care. C3I centers vary in size, implementation strategies used, and treatment approaches. We examined associations of these contextual factors with treatment reach and smoking cessation effectiveness. METHODS: This cross-sectional study used survey data from 28 C3I centers that reported tobacco treatment data during the first 6 months of 2021. Primary outcomes of interest were treatment reach (reach)-the proportion of patients identified as currently smoking who received at least one evidence-based tobacco treatment component (eg, counseling and pharmacotherapy)-and smoking cessation effectiveness (effectiveness)-the proportion of patients reporting 7-day point prevalence abstinence at 6-month follow-up. Center-level differences in reach and effectiveness were examined by center characteristics, implementation strategies, and tobacco treatment components. RESULTS: Of the total 692,662 unique patients seen, 44,437 reported current smoking. Across centers, a median of 96% of patients were screened for tobacco use, median smoking prevalence was 7.4%, median reach was 15.4%, and median effectiveness was 18.4%. Center-level characteristics associated with higher reach included higher smoking prevalence, use of center-wide TTP, and lower patient-to-tobacco treatment specialist ratio. Higher effectiveness was observed at centers that served a larger overall population and population of patients who smoke, reported a higher smoking prevalence, and/or offered electronic health record referrals via a closed-loop system. CONCLUSION: Whole-center TTP implementation among inpatients and outpatients, and increasing staff-to-patient ratios may improve TTP reach. Designating personnel with tobacco treatment expertise and resources to increase tobacco treatment dose or intensity may improve smoking cessation effectiveness

    Lateral tilt during IVC filter placement does not predict the need for advanced filter retrieval techniques

    Get PDF
    PURPOSEWe aimed to determine if lateral inferior vena cava (IVC) filter tilt at placement predicts the need for subsequent advanced retrieval techniques.METHODSA retrospective chart review was performed of all Gunther Tulip IVC filter placements with subsequent retrievals between February 2015 and October 2017. Chart and imaging review was performed for patient, filter placement, and filter retrieval demographics/characteristics. Degree of agreement between two measurement sets was evaluated with the intraclass correlation (ICC) analysis. Categorical variables were compared with chi-square or Fisher exact test, as appropriate. Kendall rank correlation was used to measure correlation between categorical variables.RESULTSThere was poor agreement between filter tilt angle at the time of placement and retrieval (ICC coefficient, 0.54). Mean difference ± standard deviation between tilt angle at the time of placement and retrieval was 4.6°±4.3° (p = 0.35). Among patient- or procedure-related factors, a common femoral vein access on placement (regression coefficient, -2.90; p = 0.039) was associated with a lower difference between placement and retrieval filter tilt angles compared to internal jugular vein access. Higher filter tilt angle measured at the time of retrieval (OR: 1.19, p = 0.025), hook embedment (OR: 77.3, p < 0.001), and a longer dwell time (OR: 1.25, p = 0.002) were associated with the need for advanced retrieval techniques. However, in univariate and multivariate analysis filter tilt angle at the time of placement was not associated with the subsequent need for advanced retrieval technique (p = 0.16).CONCLUSIONLateral tilt at the time of placement is poorly associated with lateral tilt at the time of retrieval and does not correlate with the need for advanced retrieval technique
    • …
    corecore