48 research outputs found

    1-Year outcomes after transcatheter aortic valve replacement with balloon-expandable versus self-expandable valves

    Get PDF
    BACKGROUND The use of a balloon-expandable transcatheter heart valve previously resulted in a greater rate of device success compared with a self-expandable transcatheter heart valve. OBJECTIVES The aim of this study was to evaluate clinical and echocardiographic outcome data at longer term follow-up. METHODS The investigator-initiated trial randomized 241 high-risk patients with symptomatic severe aortic stenosis and anatomy suitable for treatment with both balloon- and self-expandable transcatheter heart valves to transfemoral transcatheter aortic valve replacement with either device. Patients were followed-up for 1 year, with assessment of clinical outcomes and echocardiographic evaluation of valve function. RESULTS At 1 year, the rates of death of any cause (17.4% vs. 12.8%; relative risk [RR]: 1.35; 95% confidence interval [CI]: 0.73 to 2.50; p ¼ 0.37) and of cardiovascular causes (12.4% vs. 9.4%; RR: 1.32; 95% CI: 0.63 to 2.75; p ¼ 0.54) were not statistically significantly different in the balloon- and self-expandable groups, respectively. The frequencies of all strokes (9.1% vs. 3.4%; RR: 2.66; 95% CI: 0.87 to 8.12; p ¼ 0.11) and repeat hospitalization for heart failure (7.4% vs. 12.8%; RR: 0.58; 95% CI: 0.26 to 1.27; p ¼ 0.19) did not statistically significantly differ between the 2 groups. Elevated transvalvular gradients during follow-up were observed in 4 patients in the balloon-expandable group (3.4% vs. 0%; p ¼ 0.12); all were resolved with anticoagulant therapy, suggesting a thrombotic etiology. More than mild paravalvular regurgitation was more frequent in the self-expandable group (1.1% vs. 12.1%; p ¼ 0.005). CONCLUSIONS Despite the higher device success rate with the balloon-expandable valve, 1-year follow-up of patients in CHOICE (Randomized Comparison of Transcatheter Heart Valves in High Risk Patients With Severe Aortic Stenosis: Medtronic CoreValve Versus Edwards SAPIEN XT Trial), with limited statistical power, revealed clinical outcomes after transfemoral transcatheter aortic valve replacement with both balloon- and self-expandable prostheses that were not statistically significantly different. (A Comparison of Transcatheter Heart Valves in High Risk Patients With Severe Aortic Stenosis: The CHOICE Trial; NCT01645202) (J Am Coll Cardiol 2015;66:791–800) © 2015 by the American College of Cardiology Foundation

    Comparison of clinical outcomes between Magmaris and Orsiro drug eluting stent at 12 months: Pooled patient level analysis from BIOSOLVE II–III and BIOFLOW II trials

    Get PDF
    Background: The aim of this study was to compare the 12-month clinical outcomes of patients treated with Magmaris or Orsiro. Second generation drug-eluting absorbable metal scaffold Magmaris (Dreams 2G) has proved to be safe and effective in the BIOSOLVE-II study. Similarly, biodegradable polymer sirolimus-eluting stent, Orsiro has shown notable clinical results even in all-comer populations. Methods: Magmaris group patients were taken from the BIOSOLVE-II and BIOSOLVE-III trials, while the patients from Orsiro group were enrolled in BIOFLOW-II trial. The primary outcome was explored using a time-to-event assessment of the unadjusted clinical outcomes for target lesion failure (TLF) at 12 months, followed by a multivariate analysis adjusting for all the significantly different covariates between the groups. Results: The study population consisted of 482 patients (521 lesions), 184 patients (189 lesions) in Magmaris group and 298 patients (332 lesions) in Orsiro group. The mean age was 65.5 ± 10.8 and 62.7 ± 10.4 years in Magmaris and Orsiro groups, respectively (p = 0.005). Magmaris and Orsiro unadjusted TLF rates were 6.0 and 6.4% with no significant difference between the groups (p = 0.869). In the multivariate analysis, there were no meaningful differences between Magmaris and Orsiro groups. Finally, none of the groups presented device thrombosis cases at 12 months. Conclusion: At 12 months there were no significant differences between Magmaris and Orsiro groups neither in the unadjusted assessment nor in the multivariate analysis for target lesion failure. These results should be taken as hypothesis generating and may warrant a head to head comparison on a randomized fashion

    Transcatheter Aortic Valve Implantation With the Third Generation Balloon-Expandable Bioprosthesis in Patients With Severe Landing Zone Calcium

    No full text
    Device success of earlier generation balloon-expandable transcatheter heart valves (BE-THV) is lower in patients with severe landing zone calcium (LZC). We sought to explore the impact of LZC on the outcome of transcatheter aortic valve implantation (TAVI) with the next generation Edwards Sapien 3 BE-THV. In the present study, severe LZC was defined as severe aortic valve cusp calcium (AVC) and/or left ventricular outflow tract calcium (LVOTC) on computed tomography. Patients who underwent TAVI for pure/predominant aortic regurgitation, bicuspid aortic valve disease, or failed bioprosthetic valve were excluded. Out of 350 patients who underwent TAVI with the Edwards Sapien 3 (age 80.7 ± 6.1, female: 45.1%, Society of Thoracic Surgeons score: 4.9 ± 3.8, transfemoral: 97.4%), 106 (30.3%) had severe LZC; 78 severe AVC (22.3%) and 49 severe LVOTC (14.0%). Severe LZC was associated with lower device success (96.2% vs 100%, p = 0.008) driven by more prosthetic valve regurgitation (PVR, p = 0.008). On multivariable analysis, PVR was associated with severe LVOTC (odds ratio [95% confidence interval] 2.130 [1.092 to 4.158]) but not with severe AVC (1.529 [0.835 to 2.800]). Balloon predilatation (BPreD) was performed in 42.5% of patients with severe LZC (vs 19.3% in nonsevere LZC; p <0.001) and was associated with prolonged procedural time (p = 0.001) and higher irradiation exposure (p = 0.027). Device success (p = 0.311), major procedural complications (p = 0.132), 30-day safety end point (p = 0.815), and PVR (p = 0.684) were not significantly different between patients with severe LZC who underwent BPreD versus direct TAVI. In conclusion, device success of the third generation BE-THV is lower in severe LZC driven by more PVR, especially in patients with severe LVOTC. In those patients, BPreD prolonged the procedure without improving THV performance

    Long-Term Clinical Outcome of Early Generation Versus New-Generation Drug-Eluting Stents in 481 Patients Undergoing Rotational Atherectomy: A Retrospective Analysis

    Full text link
    INTRODUCTION New-generation drug-eluting stents (NG-DES) are superior to early generation DES (EG-DES) in the majority of lesion and patient subsets, but comparative data in patients with severely calcified coronary lesions are lacking. This study aims to compare clinical outcomes of EG-DES and NG-DES in patients undergoing rotational atherectomy (RA) in calcified lesions. METHODS Data of 268 patients (288 lesions) treated with EG-DES and 213 patients (225 lesions) receiving NG-DES after RA were retrospectively analyzed from a single-center registry. All major adverse cardiac events (MACE) were assessed at 2 years. RESULTS Compared to the EG-DES group, patients with NG-DES more commonly had diabetes mellitus (31.9% vs. 40.9%; p = 0.04), left main lesions (7.6% vs. 17.3%; p < 0.001) and chronic total occlusions (3.5% vs. 8.5%; p = 0.016), and had a higher total stent length (30.5, IQR 20-40 mm, vs. 38, IQR 22-53 mm, p < 0.001). The Kaplan-Meier estimated rate of cardiovascular events at 2 years showed a lower incidence of death (13.5% vs. 8.2%, log-rank p = 0.13; adjusted HR after Cox regression analysis 0.49; 95% CI 0.26-0.92; p = 0.03) and a lower MACE rate (31.1% vs. 21.1%, log-rank p = 0.04; adjusted HR 0.65; 95% CI 0.42-0.98; p = 0.04) in the NG-DES group. CONCLUSIONS Although RA is performed in more complex patients and lesions in the NG-DES era, use of NG-DES is associated with lower rates of death and MACE at 2 years as compared to EG-DES

    Fate and long-term prognostic implications of mitral regurgitation in patients undergoing transcatheter aortic valve replacement

    No full text
    Background: The management of patients with mitral regurgitation (MR) undergoing transcatheter aortic valve replacement (TAVR) is challenging. We sought to investigate the evolution and long-term prognostic impact of residual post-TAVR MR. Methods: The severity of MR was assessed at baseline and at 30 days and six months post-TAVR. Left ventricular mass and volumes were assessed by magnetic resonance imaging at two weeks and six months post-TAVR. Results: The study included 970 patients (age, 80.6 ± 6.2 years; female, 53.2%; Society of Thoracic Surgeons score, 5.2 ± 4.6). Moderate-severe MR at baseline improved at 30-day post-TAVR in 60% of cases, and TAVR with the Medtronic CoreValve (OR: 0.44 [0.23–0.86]) was associated with a lower likelihood of improvement. Further MR improvement continued beyond 30 days post-TAVR especially in patients with a significant improvement of left ventricular volume and mass. Stratified by the severity of MR at 30 days post-TAVR, the 5-year cumulative incidence of the composite of cardiovascular mortality or heart failure hospitalization was 37.5%, 40.0%, and 58.2% in patients with none-mild, moderate, and severe MR, respectively (log rank p < .001; adjusted hazard ratio of severe vs. none-mild MR: 4.83 [2.49–9.38]. Conclusions: MR improves in a majority of patients early after TAVR, and its evolution continues thereafter in line with reverse cardiac remodeling. Residual post-TAVR severe MR is associated with adverse long-term outcome. Therefore, intervention to treat severe MR persisting after TAVR should be considered by the heart team

    Plaque characteristics of nonobstructive coronary lesions in diabetic patients: an intravascular ultrasound virtual histology analysis

    No full text
    Patients with diabetes mellitus are known to be at increased risk for acute cardiovascular events. We used intravascular ultrasound virtual histology (IVUS-VH) to examine whether nonobstructive coronary artery lesions of diabetic patients have distinct plaque composition and morphology compared with nondiabetic patients

    Diazepam versus fentanyl for premedication during percutaneous coronary intervention: results from the Myocardial Protection by Fentanyl during Coronary Intervention (PROFIT) Trial

    No full text
    BACKGROUND: Sedation is a cornerstone in the premedication for percutaneous coronary intervention (PCI). Benzodiazepines and opioids are frequently used. Previous results suggest that opioids mimic the adaptation to ischemia during repeated balloon inflations and may provide direct myocardial protection in addition to their sedative effect. However, no comparative data exist. METHODS: We conducted a prospective, randomized, controlled, single-blind trial comparing diazepam and fentanyl in 276 patients undergoing elective PCI. Patients were randomized to either diazepam 5 mg sublingually or fentanyl 0.05 mg or 0.1 mg intravenously at least 5 minutes prior to the first balloon inflation. The primary end-point was the postprocedural elevation of myocardial markers of necrosis defined as an elevation of cardiac troponin T > or = 0.01 ng/ml. RESULTS: The three groups had similar baseline clinical, angiographic, and procedural characteristics, with no significant differences in lesion morphology, procedural complexity, or adjunctive medical treatment. No significant variation in the hemodynamic response to the study drugs was observed in the three groups. The rate of postprocedural troponin T elevation was 28% in the diazepam group, 20% in the fentanyl 0.05 mg group, and 30% in the fentanyl 0.1 mg group (P = 0.26). Rates of postprocedural myocardial infarction were 3%, 2%, and 2%, respectively (P = 0.84), with one case of in-hospital death in the diazepam group and no urgent TVR in the whole study population. CONCLUSION: Although providing a well-tolerated alternative to diazepam for sedation during PCI, fentanyl did not provide additional cardioprotection assessed through the postinterventional elevation of cardiac troponin T during elective coronary intervention
    corecore