66 research outputs found

    Technical and Clinical Outcome of Talent versus Endurant Endografts for Endovascular Aortic Aneurysm Repair

    Get PDF
    The technical evolution of endografts for the interventional management of infrarenal abdominal aortic aneurysms (AAA) has allowed a continuous expansion of indications. This study compares the established Talent endograft with its successor, the Endurant endograft, taking individual aortoiliac anatomy into account.From June 2007 to December 2010, 35 patients with AAA were treated with a Talent endograft (33 men) and 36 patients with an Endurant endograft (34 men). Aortoiliac anatomy was evaluated in detail using preinterventional computed tomography angiography. The 30-day outcome of both groups were compared regarding technical and clinical success as well as complications including endoleaks.The Endurant group included more patients with unfavorable anatomy (kinking of pelvic arteries, p = 0.017; shorter proximal neck, p = 0.084). Primary technical success was 91.4% in the Talent group and 100% in the Endurant group (p = 0.115). Type 1 endoleaks occurred in 5.7% of patients in the Talent group and in 2.8% of those in the Endurant group (p = 0.614). Type 3 endoleaks only occurred in the Talent group (2.9% of patients; p = 0.493). Type 2 endoleaks were significantly less common in the Endurant group than in the Talent group (8.3% versus 28.6%; p = 0.035). Rates of major and minor complications were not significantly different between both groups. Primary clinical success was significantly better in the Endurant group (97.2%) than in the Talent group (80.0%) (p = 0.028).Endurant endografts appear to have better technical and clinical outcome in patients with difficult aortoiliac anatomy, significantly reducing the occurrence of type 2 endoleaks

    Artifacts In Magnetic Resonance Imaging and Computed Tomography Caused By Dental Materials

    Get PDF
    BACKGROUND: Artifacts caused by dental restorations, such as dental crowns, dental fillings and orthodontic appliances, are a common problem in MRI and CT scans of the head and neck. The aim of this in-vitro study was to identify and evaluate the artifacts produced by different dental restoration materials in CT and MRI images. METHODS: Test samples of 44 materials (Metal and Non-Metal) commonly used in dental restorations were fabricated and embedded with reference specimens in gelatin moulds. MRI imaging of 1.5T and CT scan were performed on the samples and evaluated in two dimensions. Artifact size and distortions were measured using a digital image analysis software. RESULTS: In MRI, 13 out of 44 materials produced artifacts, while in CT 41 out of 44 materials showed artifacts. Artifacts produced in both MRI and CT images were categorized according to the size of the artifact. SIGNIFICANCE: Metal based restoration materials had strong influence on CT and less artifacts in MRI images. Rare earth elements such as Ytterbium trifluoride found in composites caused artifacts in both MRI and CT. Recognizing these findings would help dental materials manufacturers and developers to produce materials which can cause less artifacts in MRI and CT images

    In vivo imaging of pancreatic tumours and liver metastases using 7 Tesla MRI in a murine orthotopic pancreatic cancer model and a liver metastases model

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Pancreatic cancer is the fourth leading cause of tumour death in the western world. However, appropriate tumour models are scarce. Here we present a syngeneic murine pancreatic cancer model using 7 Tesla MRI and evaluate its clinical relevance and applicability.</p> <p>Methods</p> <p>6606PDA murine pancreatic cancer cells were orthotopically injected into the pancreatic head. Liver metastases were induced through splenic injection. Animals were analyzed by MRI three and five weeks following injection. Tumours were detected using T2-weighted high resolution sequences. Tumour volumes were determined by callipers and MRI. Liver metastases were analyzed using gadolinium-EOB-DTPA and T1-weighted 3D-Flash sequences. Tumour blood flow was measured using low molecular gadobutrol and high molecular gadolinium-DTPA.</p> <p>Results</p> <p>MRI handling and applicability was similar to human systems, resolution as low as 0.1 mm. After 5 weeks tumour volumes differed significantly (p < 0.01) when comparing calliper measurments (n = 5, mean 1065 mm<sup>3</sup>+/-243 mm<sup>3</sup>) with MRI (mean 918 mm<sup>3</sup>+/-193 mm<sup>3</sup>) with MRI being more precise. Histology (n = 5) confirmed MRI tumour measurements (mean size MRI 38.5 mm<sup>2</sup>+/-22.8 mm<sup>2 </sup>versus 32.6 mm<sup>2</sup>+/-22.6 mm<sup>2 </sup>(histology), p < 0,0004) with differences due to fixation and processing of specimens. After splenic injection all mice developed liver metastases with a mean of 8 metastases and a mean volume of 173.8 mm<sup>3</sup>+/-56.7 mm<sup>3 </sup>after 5 weeks. Lymphnodes were also easily identified. Tumour accumulation of gadobutrol was significantly (p < 0.05) higher than gadolinium-DTPA. All imaging experiments could be done repeatedly to comply with the 3R-principle thus reducing the number of experimental animals.</p> <p>Conclusions</p> <p>This model permits monitoring of tumour growth and metastasis formation in longitudinal non-invasive high-resolution MR studies including using contrast agents comparable to human pancreatic cancer. This multidisciplinary environment enables radiologists, surgeons and physicians to further improve translational research and therapies of pancreatic cancer.</p

    Thermal ablation of unresectable liver tumors: Factors associated with partial ablation and the impact on long-term survival

    Get PDF
    Background: Thermal ablation procedures, including radiofrequency ablation (RFA) or laser-induced interstitial thermotherapy (LITT), are now well established in the treatment of malignant unresectable hepatic tumors. But the impact of partial ablation (PA) on long-term survival following computed tomography (CT)-guided radiofrequency ablation and laser- induced interstitial thermotherapy of unresectable malignant liver lesions and the associated risk factors of PA remain partially unknown. Material/Methods: This study included 254 liver tumors in 91 consecutive patients (66 men and 25 women; age 60.9±10.4 years; mean tumor size 25±14 mm [range 5–70 mm]) who underwent thermal ablation (RFA or LITT) between January 2000 and December 2007. Mean follow-up period was 21.1 month (range 1–69 months). Survival rate and local progression-free survival (PFS) were calculated for patients with complete ablation (CA) vs. patients with partial ablation (PA) to assess the impact on long-term survival. Results: Median survival after CA was 47 months compared to 25 months after PA (P=0.04). The corresponding 5-year survival rates were 44% vs. 20%. Median PFS for CA was 11 months compared to 7 months for PA (P=0.118). The sole statistically significant risk factor for PA was tumor size (>30 mm; P=0.0003). Sustained complete ablation was achieved in 71% of lesions ≀30 mm vs. 47% of lesions >30 mm. Conclusions: We conclude that achievement of complete ablation is a highly important predictor of long-term survival and that tumor size is by far the most important predictor of the likelihood of achieving complete ablation

    Endovascular repair of arterial iliac vessel wall lesions with a self-expandable nitinol stent graft system.

    No full text
    To assess the therapeutic outcome after endovascular repair of iliac arterial lesions (IALs) using a self-expandable Nitinol stent graft system.Between July 2006 and March 2013, 16 patients (13 males, mean age: 68 years) with a self-expandable Nitinol stent graft. A total of 19 lesions were treated: nine true aneurysms, two anastomotic aneurysms, two dissections, one arteriovenous fistula, two type 1B endoleaks after endovascular aneurysm repair, one pseudoaneurysm, and two perforations after angioplasty. Pre-, intra-, and postinterventional imaging studies and the medical records were analyzed for technical and clinical success and postinterventional complications.The primary technical and clinical success rate was 81.3% (13/16 patients) and 75.0% (12/16), respectively. Two patients had technical failure due to persistent type 1A endoleak and another patient due to acute stent graft thrombosis. One patient showed severe stent graft kinking on the first postinterventional day. In two patients, a second intervention was performed. The secondary technical and clinical success rate was 87.5% (14/16) and 93.8% (15/16). The minor complication rate was 6.3% (patient with painful hematoma at the access site). The major complication rate was 6.3% (patient with ipsilateral deep vein thrombosis). During median follow-up of 22.4 months, an infection of the aneurysm sac in one patient and a stent graft thrombosis in another patient were observed.Endovascular repair of various IALs with a self-expandable Nitinol stent graft is safe and effective

    Western Star (Corner Brook, N.L.), 1909-11-17

    No full text
    The Western Star began publication on Newfoundland's west coast on 4 April 1900, appearing weekly with brief semiweekly periods up to 1952, when it became a daily. The current collection contains 21 April 1900 - 31 December 1952

    Successful stent graft placement of a ruptured IIA aneurysm in a 77-year-old man with acute abdominal pain in the left lower quadrant.

    No full text
    <p><b>A</b>) Volume reconstruction (VR) shows a large left IIA aneurysm with the irregular boundaries (arrows) indicating a rupture. <b>B</b>) On axial CT scan the true size of the aneurysm is depicted with active bleeding within the thrombosed part and blood surrounding the aneurysm (arrows). <b>C</b>) Selective angiography shows a strong IIA aneurysm (arrow) with major side branches. <b>D</b>) Angiogram after stent graft placement and coiling of aneurysm shows complete exclusion of the aneurysm from blood flow.</p
    • 

    corecore