33 research outputs found
HEMODYNAMIC EFFICACY OF A NOVEL CATHETER-DEPLOYED INTRA-AORTIC MICRO-AXIAL ENTRAINMENT PUMP IN A PORCINE ACUTE HF MODEL
Magazine reporting on the activities and programs of the University Hospital at Boston University Medical Cente
Recommended from our members
Long-term mode and timing of premature ventricular complex recurrence following successful catheter ablation
Catheter ablation of PVCs is highly successful and has become the hallmark treatment for symptomatic or highly prevalent cases. However, few studies exist that evaluate the outcomes of ablation and likely mechanisms of PVC recurrence beyond 1 year of follow-up
Recommended from our members
Pulsed field ablation versus thermal energy ablation for atrial fibrillation: a systematic review and meta-analysis of procedural efficiency, safety, and efficacy.
BACKGROUND: Pulsed field ablation (PFA) induces cell death through electroporation using ultrarapid electrical pulses. We sought to compare the procedural efficiency characteristics, safety, and efficacy of ablation of atrial fibrillation (AF) using PFA compared with thermal energy ablation. METHODS: We performed an extensive literature search and systematic review of studies that compared ablation of AF with PFA versus thermal energy sources. Risk ratio (RR) 95% confidence intervals (CI) were measured for dichotomous variables and mean difference (MD) 95% CI were measured for continuous variables, where RR < 1 and MD < 0 favor the PFA group. RESULTS: We included 6 comparative studies for a total of 1012 patients who underwent ablation of AF: 43.6% with PFA (n = 441) and 56.4% (n = 571) with thermal energy sources. There were significantly shorter procedures times with PFA despite a protocolized 20-min dwell time (MD - 21.95, 95% CI - 33.77, - 10.14, p = 0.0003), but with significantly longer fluroscopy time (MD 5.71, 95% CI 1.13, 10.30, p = 0.01). There were no statistically significant differences in periprocedural complications (RR 1.20, 95% CI 0.59-2.44) or recurrence of atrial tachyarrhythmias (RR 0.64, 95% CI 0.31, 1.34) between the PFA and thermal ablation cohorts. CONCLUSIONS: Based on the results of this meta-analysis, PFA was associated with shorter procedural times and longer fluoroscopy times, but no difference in periprocedural complications or rates of recurrent AF when compared to ablation with thermal energy sources. However, larger randomized control trials are needed
Recommended from our members
Meta-analysis of Effect of Modest (≥10%) Weight Loss in Management of Overweight and Obese Patients With Atrial Fibrillation.
Obesity and atrial fibrillation (AF) are growing epidemics with significant overlap in co-morbidities. Multiple smaller studies have evaluated the effects of weight loss and risk factor modification on recurrence of AF, reduction in AF burden and improvement in AF symptom severity. The objective of this study was to determine if a modest weight loss of ≥10% of initial body weight is enough to improve outcomes in overweight or obese patients with established AF. We performed an extensive literature search and systematic review of studies that compared weight loss of ≥10% versus weight loss of less than 10% or weight gain and assessed outcomes including recurrence of AF as determined through a Holter monitor, AF burden and improvement in AF symptom severity. Risk ratio 95% confidence intervals (CI) were measured for dichotomous variables and mean difference (MD) 95% CI were measured for continuous variables, where MD >0 favors the group with ≥10% weight loss. Five studies with a total of 548 patients were included. Patients who lost ≥10% of their initial body weight experienced less recurrence of AF (risk ratio 0.29; 95% CI 0.19 to 0.44) and a larger reduction in reported event frequency (MD 1.74; 95% CI 0.70 to 2.79), episode duration (MD 2.14; 95% CI 0.04 to 4.23), global episode severity (MD 1.89; 95% CI 1.34 to 2.45), and symptom severity (MD 5.36; 95% CI 3.75 to 6.97). In conclusion, weight loss is associated with less risk of recurrent AF, reduction in AF burden, and improvement in AF symptom severity
Recommended from our members
Safety and efficacy of catheter ablation of atrial fibrillation in the very elderly (≥80 years old): Insights from the UC San Diego AF Ablation Registry.
BACKGROUND: Catheter ablation improves outcomes in symptomatic atrial fibrillation (AF) patients. However, its safety and efficacy in the very elderly (≥80 years old) is not well described. HYPOTHESIS: Ablation of AF in the very elderly is safe and effective. METHODS: We performed a retrospective study of all patients who underwent catheter ablation enrolled in the University of California, San Diego AF Ablation Registry. The primary outcome was freedom from atrial arrhythmias on or off antiarrhythmic drugs (AADs). RESULTS: Of 847 patients, 42 (5.0%) were 80 years of age or greater with a median age of 81.5 (80-82.3) and 805 (95.0%) were less than 80 years of age with a median age of 64.4 (57.6-70.2). Among those who were ≥80 years old, 29 were undergoing de novo ablation (69.0%), whereas in the younger cohort, 518 (64.5%) were undergoing de novo ablation (p = .548). There were no statistically significant differences in fluoroscopy (p = .406) or total procedure times (p = .076), AAD use (p = .611), or procedural complications (p = .500) between groups. After multivariable adjustment, there were no statistically significant differences in recurrence of any atrial arrhythmias on or off AAD (adjusted hazard ratio [AHR]: 0.75; 95% confidence interval [CI]: 0.45-1.23; p = .252), all-cause hospitalizations (AHR: 0.86; 95% CI: 0.46-1.60; p = .626), or all-cause mortality (AHR: 4.48; 95% CI: 0.59-34.07; p = .147) between the very elderly and the younger cohort. CONCLUSION: In this registry analysis, catheter ablation of AF appears similarly effective and safe in patients 80 years or older when compared to a younger cohort
Recommended from our members
Safety and acute efficacy of catheter ablation for atrial fibrillation with pulsed field ablation vs thermal energy ablation: A meta-analysis of single proportions.
BACKGROUND: Pulsed field ablation (PFA) has emerged as a novel energy source for the ablation of atrial fibrillation (AF) using ultrarapid electrical pulses to induce cell death via electroporation. OBJECTIVE: The purpose of this study was to compare the safety and acute efficacy of ablation for AF with PFA vs thermal energy sources. METHODS: We performed an extensive literature search and systematic review of studies that evaluated the safety and efficacy of ablation for AF with PFA and compared them to landmark clinical trials for ablation of AF with thermal energy sources. Freeman-Tukey double arcsine transformation was used to establish variance of raw proportions followed by the inverse with the random-effects model to combine the transformed proportions and generate the pooled prevalence and 95% confidence interval (CI). RESULTS: We included 24 studies for a total of 5203 patients who underwent AF ablation. Among these patients, 54.6% (n = 2842) underwent PFA and 45.4% (n = 2361) underwent thermal ablation. There were significantly fewer periprocedural complications in the PFA group (2.05%; 95% CI 0.94-3.46) compared to the thermal ablation group (7.75%; 95% CI 5.40-10.47) (P = .001). When comparing AF recurrence up to 1 year, there was a statistically insignificant trend toward a lower prevalence of recurrence in the PFA group (14.24%; 95% CI 6.97-23.35) compared to the thermal ablation group (25.98%; 95% CI 15.75-37.68) (P = .132). CONCLUSION: Based on the results of this meta-analysis, PFA was associated with lower rates of periprocedural complications and similar rates of acute procedural success and recurrent AF with up to 1 year of follow-up compared to ablation with thermal energy sources
Clinical factors associated with baseline history of atrial fibrillation and subsequent clinical outcomes following initial implantable cardioverter-defibrillator placement.
Atrial fibrillation (AF) is frequently present in patients with heart failure (HF) and an implantable cardioverter-defibrillator (ICD). This study aims to identify clinical factors associated with a baseline history of AF in ICD recipients, and compares subsequent clinical outcomes in those with and without a baseline history of AF.We studied 566 consecutive first-time ICD recipients at an academic center between 2011 and 2018. Logistic regression multivariable analyses were used to identify clinical factors associated with a baseline history of AF at the time of ICD implant. Cox-proportional hazard regression models were constructed for multivariate analysis to examine associations between a baseline history of AF with subsequent clinical outcomes, including ICD therapies, HF readmission, and all-cause mortality.Of all patients, 201 (36%) had a baseline history of AF at the time of ICD implant. In multivariate analyses, clinical factors associated with a baseline history of AF included hypertension, valvular heart disease, body weight, PR interval, and serum creatinine level. After multivariate adjustment for potential confounders, a baseline history of AF was associated with an increased risk of anti-tachycardia pacing (HR = 1.84, 95% CI = 1.19-2.85, P = .006), appropriate ICD shocks (HR = 1.80, 95% CI = 1.05-3.09, P = .032), and inappropriate ICD shocks (HR = 3.72, 95% CI = 1.7-7.77, P = .0001), but not other adverse outcomes.Among first-time ICD recipients, specific clinical characteristics were associated with a baseline history of AF at the time of ICD implant. After adjustment for potential confounders, a baseline history of AF was associated with a higher risk of all ICD therapies in follow-up