Media 1: Subaperture correlation based digital adaptive optics for full field optical coherence tomography
Originally published in Optics Express on 06 May 2013 (oe-21-9-10850
Sample phase extraction of a baseline measurement.
<p>Over the measurement period of 12 s several small eye movements can be seen resulting in pronounced changes in Ф<sub>1</sub> and Ф<sub>2</sub>, but almost unchanged ΔФ. In addition, the eye also shows a slight overall movement resulting in shifts of Ф<sub>1</sub> and Ф<sub>2</sub> over time.</p
Calculation of angle .
<p>Angle as calculated from measurements using OCT (red) and LDV (blue) from the two channels. Calculations were done at baseline conditions as well as during hyperoxia.</p
Geometrical situation at the posterior pole of the eye.
<p> and , probe beam wave vectors; , velocity vector; and , Doppler angles; , separation angle between probe beams; , angle between and the plane perpendicular to the detection plane; , change in illumination angle due to eye movement.</p
SLO fundus image of a venous junction.
<p>Angle is determined from the slope of the tangent to the vessel at the measured location. w<sub>sl,x</sub>, w<sub>sl,y</sub>; image width in x- and y-direction. DP; detection plane.</p
Bland-Altman of velocity measurements.
<p>Bland-Altman plot comparing velocity data as obtained with laser Doppler velocimetry and with bidirectional Doppler FD-OCT. Data are presented for baseline conditions as well as for conditions during systemic hyperoxia.</p
Sample phase extraction of a baseline measurement.
<p>Over the measurement period of 12 s the eye moved relative to the incoming laser beams resulting in pronounced changes in Ф<sub>1</sub> and Ф<sub>2</sub>, but almost unchanged ΔФ.</p
Bland-Altman plot of blood flow calculation.
<p>Bland-Altman plot comparing retinal blood flow data as calculated from measurements of blood flow velocity obtained either with laser Doppler velocimetry or with bidirectional Doppler FD-OCT combined with diameter measurements with the Dynamic Vessel Analyzer. Data are presented for baseline conditions as well as for conditions during systemic hyperoxia.</p
Velocity, diameter and blood flow data under baseline conditions and during 100% oxygen breathing measured on Doppler OCT or Laser Doppler Velocimetry study day.
<p>Velocity, diameter and blood flow data under baseline conditions and during 100% oxygen breathing measured on Doppler OCT or Laser Doppler Velocimetry study day.</p
Correlation analysis for velocity measurements.
<p>Correlation between velocity and blood flow as assessed with LDV and OCT, respectively, during baseline conditions and during hyperoxia.</p