183 research outputs found

    Response to Weintraub and Garratt

    Get PDF

    Monitoring the performance of residents during training in off-pump coronary surgery.

    Get PDF
    OBJECTIVE: Control charts (eg, cumulative sum charts) plot changes in performance with time and can alert a surgeon to suboptimal performance. They were used to compare performance of off-pump coronary artery bypass surgery between a consultant and four resident surgeons and to compare performance of off-pump coronary artery bypass surgery and conventional coronary artery bypass grafting within surgeons. METHODS: Data were analyzed for consecutive patients undergoing coronary artery bypass grafting who were operated on by one consultant or one of four residents. Conversions were analyzed by intention to treat. Perioperative death or one or more of 10 adverse events constituted failure. Predicted risks of failure for individual patients were derived from the study population. Variable life-adjusted displays and risk-adjusted sequential probability ratio test charts were plotted. RESULTS: Data for 1372 patients were analyzed; 769 of the procedures were off-pump coronary artery bypass operations (56.0%). The consultant operated on 382 patients (293 off-pump, 76.7%), and the residents operated on 990 (474 off-pump, 47.9%). Patients operated on by residents tended to be older, more obese, more likely to require an urgent operation, and more likely to need a circumflex artery graft but less likely to have triple-vessel disease. There were 7 conversions (consultant 5, residents 2). The overall failure rate was 8.5% (9.2% for consultant's operations and 8.2% for residents' operations), including 10 deaths (0.7%). Predicted and observed risks of failure were similar for all five surgeons. After 100 off-pump coronary artery bypass operations, performance was the same or better for the residents as for the consultant. For all surgeons, performance was the same or better for off-pump as for conventional coronary artery bypass grafting. CONCLUSIONS: Off-pump coronary artery bypass surgery can be safely taught to cardiothoracic residents. Implementation of continuous performance monitoring for residents is practicable

    Commentary:Who is who in this storm?

    Get PDF

    Preconditioning or postconditioning with 8-Br-cAMP-AM protects the heart against regional ischemia and reperfusion:a role for mitochondrial permeability transition

    Get PDF
    The cAMP analogue 8-Br-cAMP-AM (8-Br) confers marked protection against global ischaemia/reperfusion of isolated perfused heart. We tested the hypothesis that 8-Br is also protective under clinically relevant conditions (regional ischaemia) when applied either before ischemia or at the beginning of reperfusion, and this effect is associated with the mitochondrial permeability transition pore (MPTP). 8-Br (10 μM) was administered to Langendorff-perfused rat hearts for 5 min either before or at the end of 30 min regional ischaemia. Ca2+-induced mitochondria swelling (a measure of MPTP opening) and binding of hexokinase II (HKII) to mitochondria were assessed following the drug treatment at preischaemia. Haemodynamic function and ventricular arrhythmias were monitored during ischaemia and 2 h reperfusion. Infarct size was evaluated at the end of reperfusion. 8-Br administered before ischaemia attenuated ventricular arrhythmias, improved haemodynamic function, and reduced infarct size during ischaemia/reperfusion. Application of 8-Br at the end of ischaemia protected the heart during reperfusion. 8-Br promoted binding of HKII to the mitochondria and reduced Ca2+-induced mitochondria swelling. Thus, 8-Br protects the heart when administered before regional ischaemia or at the beginning of reperfusion. This effect is associated with inhibition of MPTP via binding of HKII to mitochondria, which may underlie the protective mechanism

    Development and Preliminary Testing of Porcine Blood-Derived Endothelial-like Cells for Vascular Tissue Engineering Applications:Protocol Optimisation and Seeding of Decellularised Human Saphenous Veins

    Get PDF
    Functional endothelial cells (EC) are a critical interface between blood vessels and the thrombogenic flowing blood. Disruption of this layer can lead to early thrombosis, inflammation, vessel restenosis, and, following coronary (CABG) or peripheral (PABG) artery bypass graft surgery, vein graft failure. Blood-derived ECs have shown potential for vascular tissue engineering applications. Here, we show the development and preliminary testing of a method for deriving porcine endothelial-like cells from blood obtained under clinical conditions for use in translational research. The derived cells show cobblestone morphology and expression of EC markers, similar to those seen in isolated porcine aortic ECs (PAEC), and when exposed to increasing shear stress, they remain viable and show mRNA expression of EC markers similar to PAEC. In addition, we confirm the feasibility of seeding endothelial-like cells onto a decellularised human vein scaffold with approximately 90% lumen coverage at lower passages, and show that increasing cell passage results in reduced endothelial coverage