AbstractIn this paper, for the first time results of works on novel miniature instrumentation for quantum rods (QR) fluorescence excitation and detection will be described. Presented solutions were developed to co-work with lab-on-a-chip (LOC) applications of QR fluorochromes in multichannel high sensitive fluorescence detection
Miniature instrument for lab-on-a-chip capillary gel electrophoresis of DNA utilizing temperature control technique
AbstractA complete miniaturized instrument for chip-based capillary gel electrophoresis of DNA with fluorometric detection method and temperature control technique is presented. Separation of single-stranded and double-stranded DNA is obtained in a few minutes utilizing reusable glass chip. Real-time detection is performed using laser-induced-fluorescence and miniature CCD camera. Applied temperature control technique affects mobility of different DNA fragments in polymer sieving matrix. Electrokinetic sample plug injection and separation, temperature stabilization and fluorometric detection are automatically performed in the miniature docking station, controlled by dedicated software with real-time fluorescence signal recognition and digital data conditioning. Presented instrument is automatic, low-cost and portable solution, enabling future application of multitemperature single strand conformation polymorphism (MSSCP) genotyping technique for sensitive detection of minor genetic variants in DNA samples
Przedkontraktowe obowiązki informacyjne kredytodawcy wobec kredytobiorcy w ustawie o odwróconym kredycie hipotecznym
Artykuł porusza problematykę obowiązku informacyjnego poprzedzającego zawarcie umowy odwróconego kredytu hipotecznego. Usługa ta z założenia adresowana jest do osób starszych, które poszukują sposobu na zwiększenie dochodów ponad środki uzyskiwane ze świadczeń emerytalnych. W opracowaniu poddano analizie regulacje ustawowe normujące przedkontraktowe obowiązki informacyjne kredytodawcy wobec potencjalnego kredytobiorcy, które ograniczają się w zasadzie do przekazania formularza informacyjnego. Rozważania prowadzą do wniosku, że ustawowy obowiązek informacyjny jest niedostosowany do specyfiki kredytobiorców
Is the diagnostic function of pacemakers a reliable source of information about ventricular arrhythmias?
Background: The aim of this study was to evaluate the reliability of pacemaker diagnostic
function in diagnosing ventricular arrhythmias.
Methods: We compared the occurrence of ventricular ectopic beats in 51 simultaneous
24-hour electrocardiogram (ECG) recordings and pacemaker event counters printouts. The
diagnostic function of a pacemaker allowed also for a qualitative assessment in 38 patients. In
these cases, the occurrence of complex forms of ventricular arrhythmias was cross-checked for
accelerated ventricular rhythms together with ventricular tachycardia, and triplets and couplets.
The detection of at least one type of complex ventricular form of arrhythmia, diagnosed by
both methods, was considered as an agreement between the methods.
Results: The results of ventricular ectopic beat counts differed significantly between the
methods. In three (6%) patients, the results were consistent; in 20 (39%) the pacemaker
underestimated results; in 28 (55%) they were overestimated. When more liberal criteria of
agreement were applied, clinically significant differences were observed in 24 (47%) patients;
in seven (29%) patients the count made by the pacemaker was lowered; and in 17 (71%) it was
overestimated. Ventricular tachycardias were recorded in 24-hour ECG in eight patients. In
three, they were identified by the pacemaker diagnostic function. In five, the pacemaker did not
recognize tachycardia (because of its frequency being below 120/min). In nine, tachycardia was
recognized falsely. The sensitivity in ventricular tachycardia diagnosis by pacemaker diagnostic
function was 38%, specificity - 70%, the value of a positive result - 25%, negative - 81%.
Conclusions: The evaluation of ventricular arrhythmias by pacemaker cannot serve as the
only reliable diagnostic method of arrhythmias. The presence of a large number of sequences
that may correspond to ventricular arrhythmia or failure to sense, should result in verification
via 24-hour ECG monitoring. (Cardiol J 2010; 17, 5: 495-502
Wskazania do 24-godzinnej rejestracji EKG u pacjenta z wszczepionym stymulatorem — zalecenia Sekcji Elektrokardiologii Nieinwazyjnej PTK oraz aktualne stanowisko ACC/AHA. Komentarz
Wskazania do 24-godzinnej rejestracji EKG u pacjenta z wszczepionym stymulatorem — zalecenia Sekcji Elektrokardiologii Nieinwazyjnej PTK oraz aktualne stanowisko ACC/AHA. Komentarz
Czy rozruszniki są wiarygodnym źródłem informacji o komorowych zaburzeniach rytmu?
Wstęp: Celem pracy była analiza wiarygodności oceny komorowych zaburzeń rytmu uzyskiwanej
dzięki funkcjom diagnostycznym rozruszników.
Materiał i metody: Występowanie pobudzeń komorowych (w okresie 24 godzin) oceniono
w 51 zapisach EKG metodą Holtera i porównano z wydrukami ze stymulatora, wykonanymi
w tym samym okresie co 24-godzinne rejestracje EKG. U 38 osób funkcja diagnostyczna
stymulatora pozwalała również na ocenę jakościową - oceniono u nich zgodność występowania
złożonych form komorowych zaburzeń rytmu, to jest przyspieszonych rytmów komorowych
i częstoskurczów komorowych łącznie, oraz trójek i par. Jako warunek zgodności w zakresie
wykrycia złożonych form komorowych zaburzeń rytmu uznano fakt stwierdzenia przynajmniej
jednego zaburzenia danego typu przez obie metody.
Wyniki: Rezultaty zliczeń pobudzeń komorowych różniły się istotnie w zakresie obu metod.
U 3 (6%) pacjentów wyniki były zgodne, u 20 (39%) stymulator zaniżył wyniki, u 28 (55%)
osób zawyżył. Stosując liberalne kryteria zgodności, różnice istotne klinicznie stwierdzono
u 24 (47%) osób, w tym u 7 (29%) zliczenia pobudzeń komorowych przez stymulator były
zaniżone, a u 17 (71%) - zawyżone. Częstoskurcze komorowe rejestrowano w 24-godzinnym
EKG u 8 pacjentów. U 3 były one rozpoznane przez funkcję diagnostyczną. U 5 osób stymulator nie
rozpoznał częstoskurczów (z powodu częstości < 120/min), u 9 pacjentów fałszywie rozpoznał ich
obecność. W rozpoznawaniu częstoskurczów komorowych czułość opcji diagnostycznej wynosiła
38%, swoistość - 70%, wartość wyniku dodatniego - 25%, ujemnego - 81%.
Wnioski: Funkcja oceniająca komorowe zaburzenia rytmu w stymulatorach nie może być
jedyną wiarygodną metodą diagnostyczną arytmii. Stwierdzenie dużej liczby sekwencji, mogących
odpowiadać komorowym zaburzeniom rytmu lub zaburzeniom czuwania, powinno skłaniać
do weryfikacji za pomocą 24-godzinnego badania EKG. (Folia Cardiologica Excerpta
2010; 5, 5: 258-265
- …