95 research outputs found

    Invited commentary

    Get PDF

    Catheter Interventions for Acute Deep Venous Thrombosis: Who, When and How

    Get PDF
    Deep venous thrombosis (DVT) is common and can be a source of morbidity by way of pulmonary embolism and post-thrombotic syndrome. Recent trials have demonstrated both early and late symptomatic benefit in venous thrombolysis and early recanalisation of the iliocaval system of selected patients. Based on the emerging evidence, national societies have published guidelines that recommend early thrombus removal in iliofemoral DVT in patients with low bleeding risk and good life expectancy. In light of these recommendations, endovenous thrombolysis and/or thrombectomy have become more popular among vein specialists. As more venous technology becomes available, surgeons and interventionalists should take pause and ensure their patient selection and treatment algorithms parallel that of existing and emerging evidence. This article summarises current evidence, technology, and the approach used at a high-volume academic centre in treating iliofemoral DVT

    Left Renal Vein Stenting in Nutcracker Syndrome: Outcomes and Implications

    Get PDF
    Nutcracker syndrome refers to the symptomatic extrinsic compression of the left renal vein presenting most commonly as flank pain and haematuria. While surgery remains the first-line treatment, stenting is gaining more acceptance and there are now several published case series. This article highlights the outcomes of left renal vein stenting in the setting of nutcracker syndrome

    Factors that influence perforator thrombosis and predict healing with perforator sclerotherapy for venous ulceration without axial reflux

    Get PDF
    ObjectiveRefluxing perforators contribute to venous ulceration. We sought to describe patient characteristics and procedural factors that (1) impact rates of incompetent perforator vein (IPV) thrombosis with ultrasound-guided sclerotherapy (UGS) and (2) impact the healing of venous ulcers (CEAP 6) without axial reflux.MethodsA retrospective review of UGS of IPV injections from January 2010 to November 2012 identified 73 treated venous ulcers in 62 patients. Patients had no other superficial or axial reflux and were treated with standard wound care and compression. Ultrasound imaging was used to screen for refluxing perforators near ulcer(s). These were injected with sodium tetradecyl sulfate or polidocanol foam and assessed for thrombosis at 2 weeks. Demographic data, comorbidities, treatment details, and outcomes were analyzed. Univariate and multivariable modeling was performed to determine covariates predicting IPV thrombosis and ulcer healing.ResultsThere were 62 patients (55% male; average age, 57.1 years) with active ulcers for an average of 28 months with compression therapy before perforator treatment, and 36% had a history of deep venous thrombosis and 30% had deep venous reflux. At a mean follow-up of 30.2 months, ulcers healed in 32 patients (52%) and did not heal in 30 patients (48%). Ulcers were treated with 189 injections, with an average thrombosis rate of 54%. Of 73 ulcers, 43 ulcers (59%) healed, and 30 (41%) did not heal. The IPV thrombosis rate was 69% in patients whose ulcers healed vs 38% in patients whose ulcers did not heal (P < .001). Multivariate models demonstrated male gender (P = .03) and warfarin use (P = .01) negatively predicted thrombosis of IPVs. A multivariate model for ulcer healing found complete IPV thrombosis was a positive predictor (P = .02), whereas a large initial ulcer area was a negative predictor (P = .08). Increased age was associated with fewer ulcer recurrences (P = .05). Predictors of increased ulcer recurrences were hypertension (P = .04) and increased follow-up time (P = .02). Calf vein thrombosis occurred after 3% (six of 189) of injections.ConclusionsThrombosis of IPVs with UGS increases venous ulcer healing in a difficult patient population. Complete closure of all IPVs in an ulcerated limb was the only predictor of ulcer healing. Men and patients taking warfarin have decreased rates of IPV thrombosis with UGS

    Evaluation of the redesigned conformable GORE TAG thoracic endoprosthesis for traumatic aortic transection

    Get PDF
    Objective: To evaluate the safety and effectiveness of the conformable GORE TAG thoracic endoprosthesis (CTAG) device (W. L. Gore and Associates, Flagstaff, Ariz) for the endovascular repair of traumatic aortic transections. Methods: A prospective, nonrandomized, multicenter trial was conducted at 21 sites. Primary safety end points included 30-day all-cause mortality. The effectiveness end point was freedom from a major device event requiring reintervention through 1-month follow-up. Results: Fifty-one subjects were enrolled between December 2009 and January 2011 with polytraumatic injuries and a mean Injury Severity Score of 32 6 14. The proximal mean intimal aortic diameter measured 24 mm, while the mean distal intimal diameter was 22 mm. A total of 57 CTAG devices were implanted (mean, 1.1/subject; range, 1-2) with a mean patient age of 44 years (range, 21-87) and a male-to-female ratio of 2:1. Technical success was 100% with an operative mortality of 0%. Femoral access was utilized in 96% of patients. The mean procedure time and blood loss was 105 minutes and 148 mL, respectively. All subjects required admission to an intensive care unit with a mean hospital stay of 14.6 days. Adjuvant techniques (ie, lumbar drains and induced hypertension) to prevent paraplegia were used in only 7.8% of patients. No patient developed paraplegia despite 63% having complete or partial left subclavian artery coverage and only 9% of those receiving left subclavian artery revascularization. In addition, there were no device compressions or major device events reported. Overall mortality at 30 days was 7.8%, and all were adjudicated by the clinical events committee as not being device or procedure related. Serious adverse events occurred in 39.2% of patients through 30 days. To date, there have been no conversions to open repair. Two site-reported endoleaks were detected during the mean follow-up of 4.2 months, which did not require reintervention. Conclusions: The CTAG device was demonstrated to be a safe and effective treatment for traumatic aortic transection based on 30-day outcomes. There were no device-related serious adverse events. (J Vasc Surg 2013;58:651-8.

    Evaluation of the redesigned conformable GORE TAG thoracic endoprosthesis for traumatic aortic transection

    Get PDF
    Objective: To evaluate the safety and effectiveness of the conformable GORE TAG thoracic endoprosthesis (CTAG) device (W. L. Gore and Associates, Flagstaff, Ariz) for the endovascular repair of traumatic aortic transections. Methods: A prospective, nonrandomized, multicenter trial was conducted at 21 sites. Primary safety end points included 30-day all-cause mortality. The effectiveness end point was freedom from a major device event requiring reintervention through 1-month follow-up. Results: Fifty-one subjects were enrolled between December 2009 and January 2011 with polytraumatic injuries and a mean Injury Severity Score of 32 6 14. The proximal mean intimal aortic diameter measured 24 mm, while the mean distal intimal diameter was 22 mm. A total of 57 CTAG devices were implanted (mean, 1.1/subject; range, 1-2) with a mean patient age of 44 years (range, 21-87) and a male-to-female ratio of 2:1. Technical success was 100% with an operative mortality of 0%. Femoral access was utilized in 96% of patients. The mean procedure time and blood loss was 105 minutes and 148 mL, respectively. All subjects required admission to an intensive care unit with a mean hospital stay of 14.6 days. Adjuvant techniques (ie, lumbar drains and induced hypertension) to prevent paraplegia were used in only 7.8% of patients. No patient developed paraplegia despite 63% having complete or partial left subclavian artery coverage and only 9% of those receiving left subclavian artery revascularization. In addition, there were no device compressions or major device events reported. Overall mortality at 30 days was 7.8%, and all were adjudicated by the clinical events committee as not being device or procedure related. Serious adverse events occurred in 39.2% of patients through 30 days. To date, there have been no conversions to open repair. Two site-reported endoleaks were detected during the mean follow-up of 4.2 months, which did not require reintervention. Conclusions: The CTAG device was demonstrated to be a safe and effective treatment for traumatic aortic transection based on 30-day outcomes. There were no device-related serious adverse events. (J Vasc Surg 2013;58:651-8.
    • …
    corecore