17 research outputs found

    Haematological and Biochemical Reference Values for Healthy Adults in the Middle Belt of Ghana

    Get PDF
    BACKGROUND: Reference values are very important in clinical management of patients, screening participants for enrollment into clinical trials and for monitoring the onset of adverse events during these trials. The aim of this was to establish gender-specific haematological and biochemical reference values for healthy adults in the central part of Ghana. METHODS: A total of 691 adults between 18 and 59 years resident in the Kintampo North Municipality and South District in the central part of Ghana were randomly selected using the Kintampo Health and Demographic Surveillance System and enrolled in this cross-sectional survey. Out of these, 625 adults made up of 316 males and 309 females were assessed by a clinician to be healthy. Median values and nonparametric 95% reference values for 16 haematology and 22 biochemistry parameters were determined for this population based on the Clinical Laboratory and Standards Institute guidelines. Values established in this study were compared with the Caucasian values being used currently by our laboratory as reference values and also with data from other African and western countries. RESULTS: REFERENCE VALUES ESTABLISHED INCLUDE: haemoglobin 113-164 g/L for males and 88-144 g/L for females; total white blood cell count 3.4-9.2 × 10(9)/L; platelet count 88-352 × 10(9)/L for males and 89-403 × 10(9)/L for females; alanine aminotransferase 8-54 U/L for males and 6-51 U/L for females; creatinine 56-119 µmol/L for males and 53-106 µmol/L for females. Using the haematological reference values based on the package inserts would have screened out up to 53% of potential trial participants and up to 25% of the population using the biochemical parameters. CONCLUSION: We have established a panel of locally relevant reference parameters for commonly used haematological and biochemical tests. This is important as it will help in the interpretation of laboratory results both for clinical management of patients and safety monitoring during a trial

    Population-Based Biochemistry, Immunologic and Hematological Reference Values for Adolescents and Young Adults in a Rural Population in Western Kenya

    Get PDF
    BACKGROUND: There is need for locally-derived age-specific clinical laboratory reference ranges of healthy Africans in sub-Saharan Africa. Reference values from North American and European populations are being used for African subjects despite previous studies showing significant differences. Our aim was to establish clinical laboratory reference values for African adolescents and young adults that can be used in clinical trials and for patient management. METHODS AND FINDINGS: A panel of 298, HIV-seronegative individuals aged 13-34 years was randomly selected from participants in two population-based cross-sectional surveys assessing HIV prevalence and other sexually transmitted infections in western Kenya. The adolescent (/=18 years) ratio and the male-to-female ratio was 1ratio1. Median and 95% reference ranges were calculated for immunohematological and biochemistry values. Compared with U.S-derived reference ranges, we detected lower hemoglobin (HB), hematocrit (HCT), red blood cells (RBC), mean corpuscular volume (MCV), neutrophil, glucose, and blood urea nitrogen values but elevated eosinophil and total bilirubin values. Significant gender variation was observed in hematological parameters in addition to T-bilirubin and creatinine indices in all age groups, AST in the younger and neutrophil, platelet and CD4 indices among the older age group. Age variation was also observed, mainly in hematological parameters among males. Applying U.S. NIH Division of AIDS (DAIDS) toxicity grading to our results, 40% of otherwise healthy study participants were classified as having an abnormal laboratory parameter (grade 1-4) which would exclude them from participating in clinical trials. CONCLUSION: Hematological and biochemistry reference values from African population differ from those derived from a North American population, showing the need to develop region-specific reference values. Our data also show variations in hematological indices between adolescent and adult males which should be considered when developing reference ranges. This study provides the first locally-derived clinical laboratory reference ranges for adolescents and young adults in western Kenya

    Clinical laboratory reference values amongst children aged 4 weeks to 17 months in Kilifi, Kenya: A cross sectional observational study

    Get PDF
    Reference intervals for clinical laboratory parameters are important for assessing eligibility, toxicity grading and management of adverse events in clinical trials. Nonetheless, haematological and biochemical parameters used for clinical trials in sub-Saharan Africa are typically derived from industrialized countries, or from WHO references that are not region-specific. We set out to establish community reference values for haematological and biochemical parameters amongst children aged 4 weeks to 17 months in Kilifi, Kenya. We conducted a cross sectional study nested within phase II and III trials of RTS, S malaria vaccine candidate. We analysed 10 haematological and 2 biochemical parameters from 1,070 and 423 community children without illness prior to experimental vaccine administration. Statistical analysis followed Clinical and Laboratory Standards Institute EP28-A3c guidelines. 95% reference ranges and their respective 90% confidence intervals were determined using non-parametric methods. Findings were compared with published ranges from Tanzania, Europe and The United States. We determined the reference ranges within the following age partitions: 4 weeks to <6 months, 6 months to less than <12 months, and 12 months to 17 months for the haematological parameters; and 4 weeks to 17 months for the biochemical parameters. There were no gender differences for all haematological and biochemical parameters in all age groups. Hb, MCV and platelets 95% reference ranges in infants largely overlapped with those from United States or Europe, except for the lower limit for Hb, Hct and platelets (lower); and upper limit for platelets (higher) and haematocrit(lower). Community norms for common haematological and biochemical parameters differ from developed countries. This reaffirms the need in clinical trials for locally derived reference values to detect deviation from what is usual in typical children in low and middle income countries
    corecore